Chenqing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chenqing Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Sudi Xu
Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
2 shared publications - Zijun Bin
Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
2 shared publications Chi Zhang
State Grid Jiangsu Electric Power CO., LTD. Research Institute No.1 Paweier Road Nanjing People's Republic of China
1 shared publication- Hongqi Ding
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210023, China
1 shared publication - Jinjiao Lin
State Grid Jiangsu Electric Power Co., Ltd., Research Institute, Nanjing 211103, China
1 shared publication - Jinyu Zhou
School of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an, China
1 shared publication
Latest Publications
- Open Access
A Two-Stage FF-RLS-Based Assessment Method for Frequency Support Capability of Grid-Following Wind and Photovoltaic Units
With the growing penetration of renewable energy, accurately characterizing the frequency support performance of grid-following wind and photovoltaic (PV) units has become increasingly important. However, conventional methods for assessing frequency support parameters often overlook practical dynamic effects, making it difficult to determine the support parameters actually realized during disturbances. To address the time-domain coupling, differential noise amplification, and parameter distortion problems in the online identification of virtual primary frequency regulation and virtual inertia coefficients, this paper establishes a frequency response model for wind and PV units that incorporates these support mechanisms together with practical physical constraints. On this basis, a two-stage forgetting-factor recursive least squares (FF-RLS) method is proposed to identify realized frequency support parameters. Exploiting the difference in response time scales between primary frequency regulation and inertial support, a quasi-steady-state frequency regulation window and a transient inertia window are constructed to decouple the two parameters. Meanwhile, Tustin phase compensation and band-limited differentiation are introduced to mitigate measurement noise and the phase mismatch between frequency and power responses. Finally, a stable window criterion is developed to adaptively extract reliable identification intervals. Simulation studies on a modified IEEE 24 bus system, together with comparisons against conventional identification methods, demonstrate the effectiveness and accuracy of the proposed method.
Open AccessA Two-Stage FF-RLS-Based Assessment Method for Frequency Support Capability of Grid-Following Wind and Photovoltaic Units
With the growing penetration of renewable energy, accurately characterizing the frequency support performance of grid-following wind and photovoltaic (PV) units has become increasingly important. However, conventional methods for assessing frequency support parameters often overlook practical dynamic effects, making it difficult to determine the support parameters actually realized during disturbances. To address the time-domain coupling, differential noise amplification, and parameter distortion problems in the online identification of virtual primary frequency regulation and virtual inertia coefficients, this paper establishes a frequency response model for wind and PV units that incorporates these support mechanisms together with practical physical constraints. On this basis, a two-stage forgetting-factor recursive least squares (FF-RLS) method is proposed to identify realized frequency support parameters. Exploiting the difference in response time scales between primary frequency regulation and inertial support, a quasi-steady-state frequency regulation window and a transient inertia window are constructed to decouple the two parameters. Meanwhile, Tustin phase compensation and band-limited differentiation are introduced to mitigate measurement noise and the phase mismatch between frequency and power responses. Finally, a stable window criterion is developed to adaptively extract reliable identification intervals. Simulation studies on a modified IEEE 24 bus system, together with comparisons against conventional identification methods, demonstrate the effectiveness and accuracy of the proposed method.
- Open Access
- 17 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4257
Dynamic Harmonic Phasor Measurement Through Coordinated Modal Subspace and Pole State Estimation
Changes in modal order alter the predictor dimension, pole-label swaps disrupt frequency continuity, and time-varying envelopes affect phasor magnitude and phase. Estimating these quantities independently can propagate errors across successive processing stages. A coordinated estimator is developed for the modal subspace, pole states, and regression parameters. An order confidence index combines the spectral gap, cumulative energy, and noise separation to select the model order and reconstruct the signal in one low-rank subspace. Variable-order recursive prediction and frequency–damping state association then form continuous pole trajectories, followed by adaptive smoothing and class-dependent unit-circle projection. The associated oscillatory and decaying direct-current (DC) poles update the Maclaurin regression atoms. Finite-window coupling is handled by either modal initialization followed by Gram iteration or a direct joint regularized solution, avoiding repeated leakage compensation. Tests with modal-order changes, frequency dynamics, modal crossings, amplitude modulation, and decaying DC show that the coordinated parameter chain preserves pole identity and improves dynamic phasor measurement. In the main dynamic test case, the mean and 95th-percentile total vector errors (TVEs) are 3.2082% and 6.0672%; the 95% paired confidence interval for the mean-TVE difference between the proposed method and estimation of signal parameters via rotational invariance techniques (ESPRIT) remains below zero. A separate RK3568 bare-metal test of the standalone three-tone Prony kernel completed 800 frames without a processing failure. Its mean processing time was 18.621 ms per frame, with observed values from 18.537 to 19.070 ms.
- 17 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4257
Open AccessDynamic Harmonic Phasor Measurement Through Coordinated Modal Subspace and Pole State Estimation
Changes in modal order alter the predictor dimension, pole-label swaps disrupt frequency continuity, and time-varying envelopes affect phasor magnitude and phase. Estimating these quantities independently can propagate errors across successive processing stages. A coordinated estimator is developed for the modal subspace, pole states, and regression parameters. An order confidence index combines the spectral gap, cumulative energy, and noise separation to select the model order and reconstruct the signal in one low-rank subspace. Variable-order recursive prediction and frequency–damping state association then form continuous pole trajectories, followed by adaptive smoothing and class-dependent unit-circle projection. The associated oscillatory and decaying direct-current (DC) poles update the Maclaurin regression atoms. Finite-window coupling is handled by either modal initialization followed by Gram iteration or a direct joint regularized solution, avoiding repeated leakage compensation. Tests with modal-order changes, frequency dynamics, modal crossings, amplitude modulation, and decaying DC show that the coordinated parameter chain preserves pole identity and improves dynamic phasor measurement. In the main dynamic test case, the mean and 95th-percentile total vector errors (TVEs) are 3.2082% and 6.0672%; the 95% paired confidence interval for the mean-TVE difference between the proposed method and estimation of signal parameters via rotational invariance techniques (ESPRIT) remains below zero. A separate RK3568 bare-metal test of the standalone three-tone Prony kernel completed 800 frames without a processing failure. Its mean processing time was 18.621 ms per frame, with observed values from 18.537 to 19.070 ms.
- Open Access
- 20 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3132-3134
Procedure analysis of UHVDC commutation failure
There may be a commutation failure during a fault or start‐up of the UHVDC inverter side. The law of commutation failure process in UHVDC converter is studied here. First, the cause of inverter commutation failures is briefly introduced. Then, the general law for the bridge arm conduction of the inverter in the process of the commutation failure is revealed. Finally, the system debugging recorded data of some commutation failures of Taizhou UHVDC inverter in China is used to verify the law. Research shows that the commutation failure will go through three stages which has obvious features: (i) the commutation failure stage, (ii) the bypass circuit formation stage, and (iii) the commutation failure recovery stage. In the last stage, the AC currents of two conducted phases increase instantly in opposite directions, which are easy to recognise. In the second stage, only the DC current increases, and the AC currents equal 0 approximately. Because of the three stages, the commutation failure valve number is easily recognised. The study on the law of commutation failure process lay the foundation for commutation failure process analysis and identification for relay protection.
- 20 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3132-3134
Open AccessProcedure analysis of UHVDC commutation failure
There may be a commutation failure during a fault or start‐up of the UHVDC inverter side. The law of commutation failure process in UHVDC converter is studied here. First, the cause of inverter commutation failures is briefly introduced. Then, the general law for the bridge arm conduction of the inverter in the process of the commutation failure is revealed. Finally, the system debugging recorded data of some commutation failures of Taizhou UHVDC inverter in China is used to verify the law. Research shows that the commutation failure will go through three stages which has obvious features: (i) the commutation failure stage, (ii) the bypass circuit formation stage, and (iii) the commutation failure recovery stage. In the last stage, the AC currents of two conducted phases increase instantly in opposite directions, which are easy to recognise. In the second stage, only the DC current increases, and the AC currents equal 0 approximately. Because of the three stages, the commutation failure valve number is easily recognised. The study on the law of commutation failure process lay the foundation for commutation failure process analysis and identification for relay protection.