Jinjiao Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jinjiao Lin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Sudi Xu
Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
2 shared publications - Chenqing Wang
Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
1 shared publication - Chuyang Wang
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication - Haodong Long
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication - Jingyan Du
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication - Mingzhong Zheng
Electric Power Research Institute, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
1 shared publication
Latest Publications
- Open Access
- 17 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4257
Dynamic Harmonic Phasor Measurement Through Coordinated Modal Subspace and Pole State Estimation
Changes in modal order alter the predictor dimension, pole-label swaps disrupt frequency continuity, and time-varying envelopes affect phasor magnitude and phase. Estimating these quantities independently can propagate errors across successive processing stages. A coordinated estimator is developed for the modal subspace, pole states, and regression parameters. An order confidence index combines the spectral gap, cumulative energy, and noise separation to select the model order and reconstruct the signal in one low-rank subspace. Variable-order recursive prediction and frequency–damping state association then form continuous pole trajectories, followed by adaptive smoothing and class-dependent unit-circle projection. The associated oscillatory and decaying direct-current (DC) poles update the Maclaurin regression atoms. Finite-window coupling is handled by either modal initialization followed by Gram iteration or a direct joint regularized solution, avoiding repeated leakage compensation. Tests with modal-order changes, frequency dynamics, modal crossings, amplitude modulation, and decaying DC show that the coordinated parameter chain preserves pole identity and improves dynamic phasor measurement. In the main dynamic test case, the mean and 95th-percentile total vector errors (TVEs) are 3.2082% and 6.0672%; the 95% paired confidence interval for the mean-TVE difference between the proposed method and estimation of signal parameters via rotational invariance techniques (ESPRIT) remains below zero. A separate RK3568 bare-metal test of the standalone three-tone Prony kernel completed 800 frames without a processing failure. Its mean processing time was 18.621 ms per frame, with observed values from 18.537 to 19.070 ms.
- 17 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4257
Open AccessDynamic Harmonic Phasor Measurement Through Coordinated Modal Subspace and Pole State Estimation
Changes in modal order alter the predictor dimension, pole-label swaps disrupt frequency continuity, and time-varying envelopes affect phasor magnitude and phase. Estimating these quantities independently can propagate errors across successive processing stages. A coordinated estimator is developed for the modal subspace, pole states, and regression parameters. An order confidence index combines the spectral gap, cumulative energy, and noise separation to select the model order and reconstruct the signal in one low-rank subspace. Variable-order recursive prediction and frequency–damping state association then form continuous pole trajectories, followed by adaptive smoothing and class-dependent unit-circle projection. The associated oscillatory and decaying direct-current (DC) poles update the Maclaurin regression atoms. Finite-window coupling is handled by either modal initialization followed by Gram iteration or a direct joint regularized solution, avoiding repeated leakage compensation. Tests with modal-order changes, frequency dynamics, modal crossings, amplitude modulation, and decaying DC show that the coordinated parameter chain preserves pole identity and improves dynamic phasor measurement. In the main dynamic test case, the mean and 95th-percentile total vector errors (TVEs) are 3.2082% and 6.0672%; the 95% paired confidence interval for the mean-TVE difference between the proposed method and estimation of signal parameters via rotational invariance techniques (ESPRIT) remains below zero. A separate RK3568 bare-metal test of the standalone three-tone Prony kernel completed 800 frames without a processing failure. Its mean processing time was 18.621 ms per frame, with observed values from 18.537 to 19.070 ms.
- Open Access
- 16 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4201
AC Fault Ride-Through Strategy for Offshore Wind Power via Diode Rectifier Unit-Based Transmission System
The offshore wind power transmission system based on a diode rectifier unit (DRU) high-voltage direct current (HVDC) faces DRU blocking under sending-end AC faults and DC overvoltage under receiving-end AC faults. To address these two types of AC fault scenarios, corresponding fault ride-through strategies are proposed. For sending-end AC faults, a fault ride-through strategy based on active voltage reduction of the receiving-end converter station is proposed. An active voltage reduction control loop based on DC current deviation is added before the original DC voltage control loop of the receiving-end converter station, so that the DC voltage can be adaptively reduced with the decrease in DC current during sending-end faults. Thus, the conduction condition of the DRU is satisfied, and wind power transmission is maintained. For receiving-end AC faults, a fault ride-through strategy based on source-side active power reduction is proposed. According to the coupling relationship between the DC voltage and the wind turbine outlet voltage, an active power reduction control loop based on the outlet voltage deviation is added before the active power control loop of the wind turbine grid-side converter. During receiving-end faults, each wind turbine actively reduces its active power output, thereby suppressing the DC-side power surplus from the source side. The effectiveness of the proposed strategies was further evaluated through comparative simulations. Taking the 50% voltage-sag cases as examples, the proposed strategy maintains the DC current and transmitted power at approximately 0.84 p.u. and 0.42 p.u., respectively, during the sending-end fault, whereas both decrease to zero under the traditional strategy. During the receiving-end fault, the proposed strategy limits the DC voltage to within 1.05 p.u. and stabilizes the sending-end and receiving-end transmitted powers at approximately 0.49 p.u., while avoiding sustained voltage and current oscillations.
- 16 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4201
Open AccessAC Fault Ride-Through Strategy for Offshore Wind Power via Diode Rectifier Unit-Based Transmission System
The offshore wind power transmission system based on a diode rectifier unit (DRU) high-voltage direct current (HVDC) faces DRU blocking under sending-end AC faults and DC overvoltage under receiving-end AC faults. To address these two types of AC fault scenarios, corresponding fault ride-through strategies are proposed. For sending-end AC faults, a fault ride-through strategy based on active voltage reduction of the receiving-end converter station is proposed. An active voltage reduction control loop based on DC current deviation is added before the original DC voltage control loop of the receiving-end converter station, so that the DC voltage can be adaptively reduced with the decrease in DC current during sending-end faults. Thus, the conduction condition of the DRU is satisfied, and wind power transmission is maintained. For receiving-end AC faults, a fault ride-through strategy based on source-side active power reduction is proposed. According to the coupling relationship between the DC voltage and the wind turbine outlet voltage, an active power reduction control loop based on the outlet voltage deviation is added before the active power control loop of the wind turbine grid-side converter. During receiving-end faults, each wind turbine actively reduces its active power output, thereby suppressing the DC-side power surplus from the source side. The effectiveness of the proposed strategies was further evaluated through comparative simulations. Taking the 50% voltage-sag cases as examples, the proposed strategy maintains the DC current and transmitted power at approximately 0.84 p.u. and 0.42 p.u., respectively, during the sending-end fault, whereas both decrease to zero under the traditional strategy. During the receiving-end fault, the proposed strategy limits the DC voltage to within 1.05 p.u. and stabilizes the sending-end and receiving-end transmitted powers at approximately 0.49 p.u., while avoiding sustained voltage and current oscillations.
- Open Access
The Optimization of Mechanical Phase-Shifting Transformer Tap Positions Based on an Open-Loop and Closed-Loop Hybrid Strategy
Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.
Open AccessThe Optimization of Mechanical Phase-Shifting Transformer Tap Positions Based on an Open-Loop and Closed-Loop Hybrid Strategy
Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.