Chelsea N. Koch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chelsea N. Koch has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Alejandro Gonzalez Della Valle
Adult Reconstruction and Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021 USA
1 shared publication- Alejandro Gonzalez Della Valle
Adult Reconstruction and Joint Replacement Center, Hospital for Special Surgery, New York, NY, USA
1 shared publication - Alexander Bryant Christ
Department of Orthopaedic Surgery, University of California, Los Angeles, USA
1 shared publication - Beth E. Shubin Stein
Hospital for Special Surgery
1 shared publication Douglas E. Padgett
Adult Reconstruction and Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021 USA
1 shared publication- Elexis C. Baral
Hospital for Special Surgery, New York, NY
1 shared publication
Latest Publications
- 22 June 2017
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 13 (3) , 241-247
Ceramic Bearings with Titanium Adapter Sleeves Implanted During Revision Hip Arthroplasty Show Minimal Fretting or Corrosion: A Retrieval Analysis
The BIOLOX® option system, consisting of a BIOLOX® delta ceramic femoral head with a titanium alloy adapter sleeve, is being increasingly utilized in revision hip arthroplasty. The sleeve protects the ceramic head from fracture and improper motion about the stem trunnion when a damaged trunnion is encountered at revision surgery. Corrosion and fretting due to metal-metal contact at the taper region of hip prosthesis create the potential of causing periprosthetic osteolysis and adverse local tissue reactions.
- 22 June 2017
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 13 (3) , 241-247
Ceramic Bearings with Titanium Adapter Sleeves Implanted During Revision Hip Arthroplasty Show Minimal Fretting or Corrosion: A Retrieval Analysis
The BIOLOX® option system, consisting of a BIOLOX® delta ceramic femoral head with a titanium alloy adapter sleeve, is being increasingly utilized in revision hip arthroplasty. The sleeve protects the ceramic head from fracture and improper motion about the stem trunnion when a damaged trunnion is encountered at revision surgery. Corrosion and fretting due to metal-metal contact at the taper region of hip prosthesis create the potential of causing periprosthetic osteolysis and adverse local tissue reactions.
- 1 October 2016
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 12 (3) , 250-254
Spontaneous Fractures of a Modern Modular Uncemented Femoral Stem
Background: Femoral stem fracture following total hip arthroplasty is an uncommon event that requires immediate revision surgery. Questions/Purposes: We report on four patients who experienced stem fractures of one design and a review of the US Food and Drug Administration adverse event reports on this design. Methods: Fracture surfaces of four EMPERION™ (Smith & Nephew, Memphis, TN) femoral stems were analyzed under optical and scanning electron microscopy. A search of the FDA's Manufacturer and User Facility Device Experience (MAUDE) that reports on all EMPERION™ adverse events was completed. Results: Fracture surfaces exhibited characteristics consistent with a fatigue fracture mechanism. Sixteen MAUDE reports claimed stem fracture or breakage of EMPERION™ stems. Conclusion: The four cases of EMPERION™ stem fractures were likely driven by small stem diameter, high offset, and high patient weight. Modular stem-sleeve femoral systems are susceptible to fatigue failure under high stress and should only be used in appropriate patients, whom are not considered obese.
- 1 October 2016
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 12 (3) , 250-254
Spontaneous Fractures of a Modern Modular Uncemented Femoral Stem
Background: Femoral stem fracture following total hip arthroplasty is an uncommon event that requires immediate revision surgery. Questions/Purposes: We report on four patients who experienced stem fractures of one design and a review of the US Food and Drug Administration adverse event reports on this design. Methods: Fracture surfaces of four EMPERION™ (Smith & Nephew, Memphis, TN) femoral stems were analyzed under optical and scanning electron microscopy. A search of the FDA's Manufacturer and User Facility Device Experience (MAUDE) that reports on all EMPERION™ adverse events was completed. Results: Fracture surfaces exhibited characteristics consistent with a fatigue fracture mechanism. Sixteen MAUDE reports claimed stem fracture or breakage of EMPERION™ stems. Conclusion: The four cases of EMPERION™ stem fractures were likely driven by small stem diameter, high offset, and high patient weight. Modular stem-sleeve femoral systems are susceptible to fatigue failure under high stress and should only be used in appropriate patients, whom are not considered obese.