Spontaneous Fractures of a Modern Modular Uncemented Femoral Stem
Authors:
- 1 October 2016
- journal article
- research article
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 12 (3) , 250-254
Abstract
Background: Femoral stem fracture following total hip arthroplasty is an uncommon event that requires immediate revision surgery. Questions/Purposes: We report on four patients who experienced stem fractures of one design and a review of the US Food and Drug Administration adverse event reports on this design. Methods: Fracture surfaces of four EMPERION™ (Smith & Nephew, Memphis, TN) femoral stems were analyzed under optical and scanning electron microscopy. A search of the FDA's Manufacturer and User Facility Device Experience (MAUDE) that reports on all EMPERION™ adverse events was completed. Results: Fracture surfaces exhibited characteristics consistent with a fatigue fracture mechanism. Sixteen MAUDE reports claimed stem fracture or breakage of EMPERION™ stems. Conclusion: The four cases of EMPERION™ stem fractures were likely driven by small stem diameter, high offset, and high patient weight. Modular stem-sleeve femoral systems are susceptible to fatigue failure under high stress and should only be used in appropriate patients, whom are not considered obese.Keywords
This publication has 13 references indexed in Scilit:
- Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip ArthroplastiesClinical Orthopaedics and Related Research, 2016
- Corrosion and Fretting of a Modular Hip System: A Retrieval Analysis of 60 Rejuvenate StemsThe Journal of Arthroplasty, 2015
- Modular Hip Implant Fracture at the Stem-Sleeve InterfaceOrthopedics, 2015
- Spontaneous fracture of diaphyseal stem of S-ROM femoral prosthesisBMJ Case Reports, 2014
- Failure of a Modular Hip Implant at the Stem-Sleeve InterfaceOrthopedics, 2013
- Discoloration of titanium alloy in acidic saline solutions with peroxideDental Materials Journal, 2013
- Femoral Stem Fracture and In Vivo Corrosion of Retrieved Modular Femoral HipsThe Journal of Arthroplasty, 2012
- Discoloration and Dissolution of Titanium and Titanium Alloys with Immersion in Peroxide- or Fluoride-containing SolutionsDental Materials Journal, 2008
- Late Fatigue Fracture of a Modern Cemented Forged Cobalt Chrome Stem for Total Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Fracture of Femoral Prostheses in Total Hip ReplacementClinical Orthopaedics and Related Research, 1975