KLKyu-Dong Lee

Kyu-Dong Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kyu-Dong Lee has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Corrigendum: TorbeamNN: machine learning-based steering of ECH mirrors on KSTAR (2025 Plasma Phys. Control. Fusion 67 055036)

    by Andrew Rothstein, Minseok Kim, Minho Woo, Minsoo Cha, Cheolsik Byun, Sangkyeun Kim, Keith Erickson, Youngho Lee, Joshua Josephy-Zack, Jalal Butt, et al.

  • Open Access

    TorbeamNN: machine learning-based steering of ECH mirrors on KSTAR

    by Andrew Rothstein, Minseok Kim, Minho Woo, Minsoo Cha, Cheolsik Byun, Sangkyeun Kim, Keith Erickson, Youngho Lee, Josh Josephy-Zack, Jalal Butt, et al.

    We have developed TorbeamNN: a machine learning surrogate model for the TORBEAM ray tracing code to predict electron cyclotron heating (ECH) and current drive locations in tokamak plasmas. TorbeamNN provides more than a 100 times speed-up compared to the highly optimized and simplified real-time implementation of TORBEAM without any reduction in accuracy compared to the offline, full fidelity TORBEAM code. The model was trained using KSTAR ECH mirror geometries and works for both O-mode and X-mode absorption. The TorbeamNN predictions have been validated both offline and real-time in experiment. TorbeamNN has been utilized to track an ECH absorption vertical position target in dynamic KSTAR plasmas as well as under varying toroidal mirror angles and with a minimal average tracking error of 0.5 cm.


  • Development of V-band Doppler reflectometer based on frequency steering phased array antenna

    by Seong-Heon Seo, Boseong Kim, K D Lee, Hyunho Wi, Sung Joon Yoon, Hee Sung Yoon, Junhee Lee, Changoo Park

    KSTAR Doppler reflectometer (DR) is designed based on frequency steering phased array antenna (FSPAA) operating in X-mode over the full V-band (50–75 GHz). In the FSPAA system, the microwave radiation angle varies as a function of frequency, allowing rapid changes in the radiation angle without mechanical movement. This is a very attractive advantage in fusion reactor environments where the concept of maintenance-free is important. However, FSPAA has limitations in microwave radiation in the broadside direction due to the open-stopband problem. In this paper, various types of series feeds are developed to suppress open-stopband and their performance is tested based on computer simulations. Directional coupling feed shows the best performance. Two prototype FSPAAs consisting of 8 antenna elements with directional coupling feed networks have been manufactured using electroforming technology. The performance of the manufactured FSPAAs are experimentally measured. Since microwaves are radiated with uniform power over an angular range of ± 40 ∘ for a frequency sweep of 3 GHz, the angular scan is repeated 9 times over the entire V-band. A prototype KSTAR DR based on a bistatic antenna configuration is assembled using the two FSPAAs. The performance of the prototype DR is tested using a rotating corrugated aluminum wheel in the laboratory.

  • Development of a multi-channel mm-wave interferometer for the versatile experiment spherical torus (VEST)

    by J. Wang, J. H. Byun, S.-H. Seo, D. J. Lee, Y. U. Nam, J.-W. Juhn, K. D. Lee, M. K. Kim, Y. S. Hwang, C. Sung

    The 94 GHz single-channel interferometer at the versatile experiment spherical torus has been upgraded into a multi-channel heterodyne interferometer for electron density profile measurements. Five Gaussian beam chords generated by a pair of Powell lenses and collimating lenses are vertically spaced at 75 mm intervals from the midplane to the lower part of the main chamber. The beams passing through the plasma are received at a detector array consisting of a half-wave rotator and modules consisting of an integrated lens antenna and mixer. The local oscillator beam is expanded by another pair of Powell lenses and received at the detector array as well. The signal frequencies are down-converted to 10–70 MHz intermediate frequencies, and then their phases are converted into line-integrated electron densities. The optical system was optimized using Gaussian beam approximation and the optics design tool, CODE V. For the commissioning of the complete system, a single-channel setup was first tested and verified by comparing the results with a V-band frequency sweeping interferometer. The data from five channels were then obtained and compared with the time trace obtained by 1 kHz Thomson scattering at the midplane of the plasma.


  • Electron cyclotron emission calibration with Thomson scattering using a wide scan of toroidal magnetic field of KSTAR

    by K. D. Lee, J. H. Lee, Y. U. Nam, S. Pyo

    The Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak is capable of operating at a wide range of toroidal magnetic fields up to 3.5 T at the major radius. The electron cyclotron emission (ECE) diagnostic on KSTAR is required to cover a broad frequency range for electron temperature profile measurements in both the low and high field sides. To meet these broadband requirements, the ECE system consists of W-band (78–110 GHz) and D-band (110–162 GHz) heterodyne radiometers. The two radiometers are connected to 28 and 48 detection channels, respectively. However, since the absolute ECE calibration based on the hot–cold calibration has been very challenging, an alternative method of calibration was performed using Thomson scattering measurements and varying toroidal magnetic fields. As the toroidal magnetic field is scanned from 1.6 to 3.2 T in steps of 0.2 T, most of the 76 ECE channels are calibrated relatively by the electron temperature values of Thomson scattering in a narrow region (0.2 < r/a <0.6). In this article, the methodological details of the ECE calibration are described. In addition, to demonstrate the robustness of the ECE calibration factors, the calibrated electron temperature profiles from ECE measurements are compared with the ion temperature profiles in terms of the plasma position as the plasma positon shifts outward.


  • Open Access

    DECAF cross-device characterization of tokamak disruptions indicated by abnormalities in plasma vertical position and current

    by V. Zamkovska, S.A. Sabbagh, M. Tobin, J.W. Berkery, J.D. Riquezes, Y.S. Park, K. Erickson, J. Butt, J.G. Bak, J. Kim, et al.

    Abnormal (deviating from the target) variations in the plasma vertical positionZand current Ip(such as vertical displacements, transient Ip‘spikes’ and quenches) constitute common elements of a disruption, a phenomenon that is to be mitigated, or ultimately avoided in future reactor-relevant tokamaks. While these abnormalities are generally recognized cross-shot and cross-device, details in terms of appearance (or not) and order of these abnormalities in disruption event chains (DEC) are bound to the plasma state at the time of the chain initiation. Detection of these abnormalities is thus indicative not only of the onset of the plasma collapse itself but also of the disruption driving cause that is promoted at a particular plasma state. Here, the occurrence of disruptions, explored via the detection of an Ipquench, and the analysis of DEC constituted by IpandZabnormalities is reported for in total seven full device-year pairs of operation of three machines (4, 2 and 1 years of KSTAR, MAST-U and NSTX-U operation, respectively) using the DECAF code expanded tools and capabilities. It is shown that the disruption occurrence depends not only on the details of the plasma state but also on (device-dependent) technical elements of the shot exit scenario. Year-to-year changes in the main disruption causes and a reduction in the disruptivity rate, bound by device and operation upgrades, are reported. Particular trigger instances of DEC (and the full chains when applicable) are shown to occupy different parts of the operation space diagrams, in accordance with prior expectations. Plasma elongation is identified as an important factor influencing details of the chains and its role will be further explored.


  • Development of a field-reversed configuration device using radio frequency antennas to produce E × B for current-drive

    by Kiyong Lee, Soo Ouk Jang, Seungryul Yoo, Kyu Dong Lee

    A unique field-reversed configuration (FRC) experiment is presently being assembled at the Plasma Technology Research Institute, KFE. It is a compact small-scale FRC device, which uses a set of radio frequency (RF) antennas to produce an internal E × B that drives the electrons for current-drive, in which E is the electric field and B is the magnetic field. This is very similar to the rotating magnetic field (RMF) current-drive, where the horizontal and vertical antennas are driven 90° out of phase. For this device, the RF antennas are arranged differently than the RMF. The RF antennas, being two separate sets, are positioned inside the vacuum chamber. Each set consists of 8 coils, for a total of 16 coils, where 80~100 kHz sine and cosine waveform currents are applied. One set of coils generates a radial B-field, while the other set provides an E-field in the z-direction. As the phase changes, the E and B fields are switched by these two sets. Nevertheless, E × B propagates in the same θ-direction so that this allows the electrons to rotate around the circumference of the device. The FRC device will test wave heating by launching 2.45 GHz microwaves. Also, passive stabilizers are positioned at each end to provide extra stability while preventing tilt instability. The experiment is expected to produce its first plasma in 2025.