James O’toole
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
James O’toole has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- John Atyeo
Department of Radiation Oncology, Northern Sydney Cancer Centre Royal North Shore Hospital Sydney New South Wales Australia
2 shared publications Kenny Wu
Northern Sydney Cancer Centre Royal North Shore Hospital Sydney New South Wales Australia
2 shared publicationsAndrew Le
Northern Sydney Cancer Centre Royal North Shore Hospital Sydney New South Wales Australia
1 shared publicationChris Brown
Northern Sydney Cancer Centre Royal North Shore Hospital Sydney New South Wales Australia
1 shared publication- Dasantha Jayamanne
Northern Sydney Clinical School, Faculty of Medicine and Health The University of Sydney Sydney New South Wales Australia
1 shared publication Kirsten van Gysen
Department of Radiation Oncology, Northern Sydney Cancer Centre, Royal North Shore Hospital, Reserve Road, St Leonards, NSW, Australia
1 shared publication
Latest Publications
- Open Access
- 1 December 2021
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 68 (4) , 364-370
Improving efficiency in the radiation management of multiple brain metastases using a knowledge-based planning solution for single-isocentre volumetric modulated arc therapy (VMAT) technique
Introduction: This study aimed to develop a single-isocentre volumetric modulated arc therapy (si-VMAT) technique for multiple brain metastases using knowledge-based planning software, comparing it with a multipleisocentre stereotactic radiosurgery (mi-SRS) planning approach. Methods: Twenty-six si-VMAT plans were created and uploaded into RapidPlan (TM) (RP) to create a si-VMAT model. Ten patients, with 2 to 6 metastases (mets), were planned with a si-VMAT technique utilising RP, and a mi-SRS technique on Brainlab iPlan. Paddick Conformity Index (PCI) was used to compare conformity. The volumes of the brain receiving 15Gy, 12Gy, 10Gy, 7.5Gy and 3Gy were also compared. Retrospective treatment times from the last eight patients treated were averaged for pre-imaging and beam on time to calculate treatment times for both techniques. Results: There was a significant difference in the PCI scores for the mi-SRS plans (M = 0.667, SD = 0.114) and si-VMAT plans (M = 0.728, SD = 0.088), with PCI values suggesting better prescription dose conformity with the si-VMAT technique (P = 0.014). Percentage of total brain volume receiving low-dose wash at four of the five different dose levels was significantly less (P < 0.05) with mi-SRS. Average time to treat a single met with current mi-SRS technique is 25.7 min, with each additional met requiring this same amount of time. The average time to treat 2- 3 mets using si-VMAT would be 25.3 min and 4+ metastases 33.5 min. Conclusion: A knowledge-based si-VMAT approach was efficient in planning and treating multi metastases while achieving clinically acceptable dosimetry with respect to dose conformity and low-dose fall off.
- 1 December 2021
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 68 (4) , 364-370
Open AccessImproving efficiency in the radiation management of multiple brain metastases using a knowledge-based planning solution for single-isocentre volumetric modulated arc therapy (VMAT) technique
Introduction: This study aimed to develop a single-isocentre volumetric modulated arc therapy (si-VMAT) technique for multiple brain metastases using knowledge-based planning software, comparing it with a multipleisocentre stereotactic radiosurgery (mi-SRS) planning approach. Methods: Twenty-six si-VMAT plans were created and uploaded into RapidPlan (TM) (RP) to create a si-VMAT model. Ten patients, with 2 to 6 metastases (mets), were planned with a si-VMAT technique utilising RP, and a mi-SRS technique on Brainlab iPlan. Paddick Conformity Index (PCI) was used to compare conformity. The volumes of the brain receiving 15Gy, 12Gy, 10Gy, 7.5Gy and 3Gy were also compared. Retrospective treatment times from the last eight patients treated were averaged for pre-imaging and beam on time to calculate treatment times for both techniques. Results: There was a significant difference in the PCI scores for the mi-SRS plans (M = 0.667, SD = 0.114) and si-VMAT plans (M = 0.728, SD = 0.088), with PCI values suggesting better prescription dose conformity with the si-VMAT technique (P = 0.014). Percentage of total brain volume receiving low-dose wash at four of the five different dose levels was significantly less (P < 0.05) with mi-SRS. Average time to treat a single met with current mi-SRS technique is 25.7 min, with each additional met requiring this same amount of time. The average time to treat 2- 3 mets using si-VMAT would be 25.3 min and 4+ metastases 33.5 min. Conclusion: A knowledge-based si-VMAT approach was efficient in planning and treating multi metastases while achieving clinically acceptable dosimetry with respect to dose conformity and low-dose fall off.
- Open Access
- 11 February 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (1) , 80-86
Parotid sparing in RapidPlan Oropharynx models: To split or not to split
Introduction: Differences in knowledge and experience, patient anatomy and tumour location and manipulation of inverse planning objectives and priorities will lead to a variability in the quality of radiation planning. The aim of this study was to investigate whether parotid glands should be treated as separate or combined structures when using knowledge‐based planning (KBP) to create oropharyngeal plans, based on the dose they receive.Method: Two separate RapidPlan (RP) models were created using the same 70 radical oropharyngeal patients. The ‘separated model’ divided the parotids into ipsilateral and contralateral structures. The ‘combined model’ did not separate the parotids. The models were independently validated using 20 patients not included in the models. The same dose constraints and priorities were applied to planning target volumes (PTVs) and organs at risk (OARs) for all plans. An auto‐generated line objective and priority was applied in both models, with parotid mean dose and V50 doses evaluated and compared.Results: Plans optimised using the combined model resulted in lower ipsilateral mean doses and lower V50 doses in 80% and 75% of cases, respectively. Fifty‐five per cent of plans produced lower mean doses for the contralateral parotid when optimised using the combined model, while lower V50 doses were evenly split between the models.Conclusion: Combining the data for both parotids into one RP model resulted in better ipsilateral parotid sparing. Results also suggest that a combined parotid model will spare dose to the contralateral parotid; however, further investigation is required to confirm these results.
- 11 February 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (1) , 80-86
Open AccessParotid sparing in RapidPlan Oropharynx models: To split or not to split
Introduction: Differences in knowledge and experience, patient anatomy and tumour location and manipulation of inverse planning objectives and priorities will lead to a variability in the quality of radiation planning. The aim of this study was to investigate whether parotid glands should be treated as separate or combined structures when using knowledge‐based planning (KBP) to create oropharyngeal plans, based on the dose they receive.Method: Two separate RapidPlan (RP) models were created using the same 70 radical oropharyngeal patients. The ‘separated model’ divided the parotids into ipsilateral and contralateral structures. The ‘combined model’ did not separate the parotids. The models were independently validated using 20 patients not included in the models. The same dose constraints and priorities were applied to planning target volumes (PTVs) and organs at risk (OARs) for all plans. An auto‐generated line objective and priority was applied in both models, with parotid mean dose and V50 doses evaluated and compared.Results: Plans optimised using the combined model resulted in lower ipsilateral mean doses and lower V50 doses in 80% and 75% of cases, respectively. Fifty‐five per cent of plans produced lower mean doses for the contralateral parotid when optimised using the combined model, while lower V50 doses were evenly split between the models.Conclusion: Combining the data for both parotids into one RP model resulted in better ipsilateral parotid sparing. Results also suggest that a combined parotid model will spare dose to the contralateral parotid; however, further investigation is required to confirm these results.