  • Simultaneous Magnetic Actuation and Compound Localization of an Ultrasound Capsule Endoscope in Endoluminal Environment

    by Zhengxin Yang, Lihao Liu, Xinze Li, Jiaqi Li, Yaoyao Cui, Yang Jiao

    Localization of the magnetic capsule endoscope is crucial to accurate actuation. Despite progress with internal magnetic field sensors and external magnetic sources, achieving reliable localization remains challenging in the presence of a time-varying internal magnetic field (IMF). This study proposes a compound localization method for an ultrasound capsule endoscope (USCE) based on an IMF sensor array and an external permanent magnet source. The method enables simultaneous 6-degrees of freedom (DOF) pose detection for closed-loop magnetic navigation and real-time ultrasound (US) beam scanning angle sensing for distortion-free US image reconstruction. First, a USCE consisting of an internal permanent magnet, a US transducer, Hall sensors, and an anchoring balloon is designed, enabling both spiral structure-based locomotion and high-quality endoluminal US imaging. Next, a compound localization strategy is presented, which realizes the separation of the time-varying IMF and external magnetic field, facilitating synchronous 6-DOF pose detection and scanning angle sensing. Furthermore, a closed-loop magnetic actuation method is proposed that allows automatic propelling in unknown tubular environments. Finally, the effectiveness of the presented method is validated through simulations, localization tests, imaging tests, and actuation tests. The demonstrated static pose detection error is 4.08 $\pm$ 1.91 mm in position norm and 2.46 $\pm$ 1.31$^\circ$ in heading orientation, within a workspace shared with the robotic manipulator. In addition, the proposed scanning angle sensing successfully corrects US image distortion, providing subsurface structures for accurate diagnosis.

  • Suppression of Radiated Emissions from Interventional Ultrasound Catheter Using Impedance Control Method: Simulation and Verification

    by Rui Zhang, Jiaqi Li, Zhile Han, Zhitian Shen, Yaoyao Cui

    Interventional ultrasound imaging technology is widely utilized for the diagnosis of a diverse range of diseases. A slender interventional catheter is an essential component of such an apparatus. The combination of a universal main unit and multiple single-frequency catheters is the development trend of such instruments to meet the increasingly complicated clinical requirements. However, significant electromagnetic interference (EMI) would probably be generated during its operation, as the single-grounded catheter may exhibit characteristics similar to those of a monopole antenna. The critical clinical significance and specific usage scenarios render the electromagnetic compatibility safety concerns of this category of equipment indispensable. Meanwhile, the low signal-to-noise ratio (SNR) of high-frequency ultrasound makes any modulation of the electric insertion likely to affect the fragile acoustic echo signal and impact the image quality. Therefore, it remains a worthwhile pursuit to develop a general method that effectively suppresses electromagnetic radiation while preserving high-frequency ultrasonic signals for different frequencies in interventional scenarios. This paper proposes an electromagnetic radiation suppression technique for interventional ultrasound catheters based on impedance control methods. By designing an impedance matching network, the method achieves impedance matching within the working frequency band and intentional impedance mismatch in the non-operational frequency band of the catheter, thereby effectively suppressing electromagnetic emissions from catheters with different operating frequencies. Simulation and experimental results demonstrate that this approach not only significantly reduces the catheter’s radiated emissions to meet the CISPR11:2016 standard but also enhances the electro-acoustic conversion efficiency of the transducer and improves imaging quality in different ultrasound frequencies.


  • Patch Fusion: A Novel Ultrafast Multi-Frequency Ultrasound Fusion Imaging Method for Pedicle Screw Navigation

    by Xiangxin Li, Xueru Yang, Jiaqi Li, Yang Jiao, Jun Shen, Yaoyao Cui, Weiwei Shao

    Intraosseous ultrasound imaging is valuable for guiding pedicle screw placement in surgery. However, single-frequency ultrasound, whether low or high, often fails to provide both adequate imaging resolution and depth simultaneously. To address this limitation, we introduce a novel ultrafast multi-frequency ultrasound patch fusion imaging method for pedicle screw navigation. This approach combines the strengths of both high-frequency and low-frequency ultrasound images, greatly enhancing the detail and clarity of the resulting images while significantly reducing the time required for image fusion. We validated our method through simulation and ex-vivo experiments, using metrics such as Information Entropy (IE), Spatial Frequency (SF), and Average Gradient (AG) to assess the quality of the fused images. We also recorded the algorithm’s execution time. The results demonstrate that our fusion method substantially improves image richness and clarity, enabling a more comprehensive and accurate assessment of the pedicle screw track. Importantly, it also reduces fusion time compared to previous methods, making real-time clinical multi-frequency ultrasound fusion imaging a viable possibility. The in-vivo experimental results of the sheep spinal pedicle screw track further demonstrate the capabilities of the patch fusion method in visualizing the internal conditions of the pedicle screw track and meeting the requirements for real-time fusion imaging. The proposed approach offers substantial support in surgical real-time navigation and ongoing monitoring within the domains of orthopedics and surgery.


  • Modeling and Suppression of Radiated Emissions for an Interventional Imaging Ultrasound Catheter Based on Single-Element Transducer

    by Rui Zhang, Zhitian Shen, Jiaqi Li, Xinle Zhu, Yaoyao Cui

    Considerable progress has been made in the field of in-vivo ultrasound imaging equipment driven by a single-element transducer in recent years. The utilization of higher ultrasound operating frequency in such equipment enables the acquisition of high-resolution images, rendering it increasingly prevalent in clinical diagnosis. The front end of such equipment typically comprises a miniature high-frequency ultrasound transducer connected to a wire measuring approximately 1.5-2.5 meters in length, forming a catheter for 360-degree rotational imaging. This structure necessitates specific considerations during electromagnetic compatibility design in contrast to conventional ultrasound equipment. The challenge lies in the significant attenuation of high-frequency ultrasound signals and the low signal-to-noise ratio. Additionally, the structure of the elongated catheter wire facilitates radiated emissions of electromagnetic noise. This paper establishes an equivalent model resembling the emission of a monopole antenna to analyze the electromagnetic radiation for the catheter through simulation. Secondly, common mode current prediction method is employed to anticipate the radiation of the catheter during operation, based on the emission mechanism of a monopole antenna. Finally, a novel combined electromagnetic interference suppression method is proposed integrating enhanced common mode impedance and suppressed transmitting power. The feasibility and effectiveness of this approach are experimentally verified and discussed.


  • Development and Control of a Dual-Mode Magnetic Intravascular Ultrasound Robot for Imaging in Tortuous Blood Vessels

    by Zhengxin Yang, Lihao Liu, Xinze Li, Jiaqi Li, Yang Jiao, Yaoyao Cui

    Atherosclerosis accounts for over 30% of global deaths annually. The intravascular ultrasound (IVUS) can provide detailed information on lesions, enabling accurate diagnosis, and treatment of vascular diseases. The existing IVUS catheters face challenges to work in tortuous blood vessels. This study presents a dual-mode magnetic IVUS robot, featuring by miniature size and high softness, which allows for intravascular imaging in hard-to-reach regions. First, the magnetic IVUS robot consisting of an acoustic-magnetic tip and a soft catheter is designed, which performs: 1) controllable bending under static magnetic fields to navigate in complex vasculature; 2) shaft-free acoustic beam scanning under dynamic magnetic fields to provide high-resolution ultrasound images. Then, the motion modeling of navigating mode and imaging mode are analyzed, respectively. Next, an integrated system and actuating strategy are established, realizing the dual-mode decoupling control of the magnetic IVUS robot. Finally, the effectiveness of the presented method is validated in vascular models, imaging phantoms, and in-vitro porcine artery vessel. The designed magnetic IVUS robot achieves dual objectives, including active angle steering at bifurcations and acoustic beam scanning at lesions, simultaneously improving the operating flexibility and imaging stability. The proposed design and control scheme demonstrate the feasibility of tortuous intravascular imaging, providing a potential solution for clinical applications.


  • Open Access

    Dual-Frequency Impedance Matching Network Design Using Genetic Algorithm for Power Ultrasound Transducer

    by Wenchang Huang, Jiaqi Li, Shuai Wu, Yan He, Xiangxin Li, Zhitian Shen, Yaoyao Cui

    Dual-frequency ultrasounds have demonstrated significant potential in augmenting thermal ablation efficiency for tumor treatment. Ensuring proper impedance matching between the dual-frequency transducer and the power amplifier system is imperative for equipment safety. This paper introduces a novel dual-frequency impedance matching network utilizing L-shaped topology and employing a genetic algorithm to compute component values. Implementation involved an adjustable capacitor and inductor network to achieve dual-frequency matching. Subsequently, the acoustic parameters of the dual-frequency HIFU transducer were evaluated before and after matching, and the effects of ultrasound thermal ablation with and without matching were compared. The proposed dual-frequency impedance matching system effectively reduced the standing wave ratio at the two resonance points while enhancing transmission efficiency. Thermal ablation experiments with matching circuits showed improved temperature rise efficiencies at both frequencies, resulting in an expanded ablation zone. The dual-frequency impedance matching method significantly enhances the transmission efficiency of the dual-frequency ultrasound system at two operational frequencies, thereby ensuring equipment safety. It holds promising prospects for application in dual-frequency ultrasound treatment.


  • A Study on Vessel Wall Shrinkage and Tissue Damage of Compressed Vascular Using Therapeutic Ultrasound

    by Jing Xie, Wenchang Huang, Yang Jiao, Xinze Li, Jiaqi Li, Yaoyao Cui

    Abstract--Ultrasound therapy has been proven to be a method of ablating diseased blood vessels. Currently, experiments have proven that external pressure on the vascular region to be treated can effectively improve the success rate of closure. However, the degree of resulting thermal damage to surrounding tissue and the reason for the effects of compression on the shrinkage of tissue-encased blood vessels remain unclear. To address this issue, we conducted a study comparing the rate of shrinkage and surrounding tissue damage of compressed vessels encapsulated in muscle tissue to vessels with normal blood flow before and after treatment using the Simulation experiment and the ex-vivo tissue experiment. The results show that in the simulated model of compressed blood vessels with static blood flow, the temperature rise is significantly higher compared to the model with simulated blood flow. In the ex-vivo tissue experiment, the shrinkage rate of the blood vessel with static blood flow reaches up to 57% after the treatment, while the area of thermal damage is 28.8mm$^{2}$. In contrast, in the blood vessel with flowing blood, the vessels undergo almost no shrinkage but still cause 5.16mm$^{2}$ of thermal damage to the surrounding tissue. Our findings confirm that compressing the vessel is an effective and necessary step for the ultrasound closure of the vessel. But at the same time, to alleviate additional thermal damage, trying to change the way and position of the compression during treatment may be necessary.