Wenchang Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenchang Huang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Yaoyao Cui
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
6 shared publications - Weiwei Shao
Chinese Academy of Sciences Suzhou Institute of Biomedical Engineering and Technology, Suzhou, China
3 shared publications - Yang Jiao
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
3 shared publications Jiaqi Li
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu, China; Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
2 shared publications- Jiaqi Li
School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, China
2 shared publications - Jing Xie
Shanghai University,School of Mechatronic Engineering and Automation,Shanghai,China
2 shared publications
Latest Publications
- 27 March 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (6) , 908-919
Evaluation of Dual-Frequency Switching HIFU for Optimizing Superficial Ablation
- 27 March 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (6) , 908-919
Evaluation of Dual-Frequency Switching HIFU for Optimizing Superficial Ablation
- Open Access
- 29 February 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (3) , 344
Dual-Frequency Impedance Matching Network Design Using Genetic Algorithm for Power Ultrasound Transducer
Dual-frequency ultrasounds have demonstrated significant potential in augmenting thermal ablation efficiency for tumor treatment. Ensuring proper impedance matching between the dual-frequency transducer and the power amplifier system is imperative for equipment safety. This paper introduces a novel dual-frequency impedance matching network utilizing L-shaped topology and employing a genetic algorithm to compute component values. Implementation involved an adjustable capacitor and inductor network to achieve dual-frequency matching. Subsequently, the acoustic parameters of the dual-frequency HIFU transducer were evaluated before and after matching, and the effects of ultrasound thermal ablation with and without matching were compared. The proposed dual-frequency impedance matching system effectively reduced the standing wave ratio at the two resonance points while enhancing transmission efficiency. Thermal ablation experiments with matching circuits showed improved temperature rise efficiencies at both frequencies, resulting in an expanded ablation zone. The dual-frequency impedance matching method significantly enhances the transmission efficiency of the dual-frequency ultrasound system at two operational frequencies, thereby ensuring equipment safety. It holds promising prospects for application in dual-frequency ultrasound treatment.
- 29 February 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (3) , 344
Open AccessDual-Frequency Impedance Matching Network Design Using Genetic Algorithm for Power Ultrasound Transducer
Dual-frequency ultrasounds have demonstrated significant potential in augmenting thermal ablation efficiency for tumor treatment. Ensuring proper impedance matching between the dual-frequency transducer and the power amplifier system is imperative for equipment safety. This paper introduces a novel dual-frequency impedance matching network utilizing L-shaped topology and employing a genetic algorithm to compute component values. Implementation involved an adjustable capacitor and inductor network to achieve dual-frequency matching. Subsequently, the acoustic parameters of the dual-frequency HIFU transducer were evaluated before and after matching, and the effects of ultrasound thermal ablation with and without matching were compared. The proposed dual-frequency impedance matching system effectively reduced the standing wave ratio at the two resonance points while enhancing transmission efficiency. Thermal ablation experiments with matching circuits showed improved temperature rise efficiencies at both frequencies, resulting in an expanded ablation zone. The dual-frequency impedance matching method significantly enhances the transmission efficiency of the dual-frequency ultrasound system at two operational frequencies, thereby ensuring equipment safety. It holds promising prospects for application in dual-frequency ultrasound treatment.
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 395-407
Multi-Frequency Ultrasound Imaging Fusion Method Based on Wavelet Transform for Guided Screw Insertion
Intraosseous ultrasound imaging can serve as a guiding tool for the placement of pedicle screws during spinal fusion surgery. Thus far, there has been limited scholarly exploration of methods for intraosseous multi-frequency ultrasound imaging, which can achieve simultaneous high resolution and deep penetration. The proposed method introduced a dynamic fusion strategy, grounded in wavelet transformation for the multi-frequency image decomposition. This strategy accomplished the effective amalgamation of high-frequency ultrasound images and low-frequency ultrasound images, enabling to obtain fused images with enhanced details and better overall image quality. A novel near-field effect elimination method was also proposed to improve the quality of ultrasound imaging in the near-field region. Experimental evaluations were conducted on isolated bovine circle bone and sheep spine with pedicle screw tracks. The fusion images are capable of effectively detecting areas within the pedicle screw track that have either ruptured or are in close proximity to rupture, even measuring the size of breaches. Evaluation criteria including information entropy, spatial frequency, average gradient, mutual information, structural similarity index, and edge information-based image fusion quality metric were employed to assess the fusion performance. Moreover, the influence of mother wavelet function selection and decomposition levels on computational complexity and fusion image quality was thoroughly discussed. The proposed method exhibited promising potential for intraosseous imaging navigation, which can aid in accurate diagnosis, treatment planning, and monitoring in fields such as orthopedics, surgery, and interventional procedures.
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (3) , 395-407
Multi-Frequency Ultrasound Imaging Fusion Method Based on Wavelet Transform for Guided Screw Insertion
Intraosseous ultrasound imaging can serve as a guiding tool for the placement of pedicle screws during spinal fusion surgery. Thus far, there has been limited scholarly exploration of methods for intraosseous multi-frequency ultrasound imaging, which can achieve simultaneous high resolution and deep penetration. The proposed method introduced a dynamic fusion strategy, grounded in wavelet transformation for the multi-frequency image decomposition. This strategy accomplished the effective amalgamation of high-frequency ultrasound images and low-frequency ultrasound images, enabling to obtain fused images with enhanced details and better overall image quality. A novel near-field effect elimination method was also proposed to improve the quality of ultrasound imaging in the near-field region. Experimental evaluations were conducted on isolated bovine circle bone and sheep spine with pedicle screw tracks. The fusion images are capable of effectively detecting areas within the pedicle screw track that have either ruptured or are in close proximity to rupture, even measuring the size of breaches. Evaluation criteria including information entropy, spatial frequency, average gradient, mutual information, structural similarity index, and edge information-based image fusion quality metric were employed to assess the fusion performance. Moreover, the influence of mother wavelet function selection and decomposition levels on computational complexity and fusion image quality was thoroughly discussed. The proposed method exhibited promising potential for intraosseous imaging navigation, which can aid in accurate diagnosis, treatment planning, and monitoring in fields such as orthopedics, surgery, and interventional procedures.
- 18 August 2023
- Published by Elsevier in Measurement
- Vol. 221
An electrical impedance matching method of dual-frequency transducers for ultrasound internal imaging
- 18 August 2023
- Published by Elsevier in Measurement
- Vol. 221
An electrical impedance matching method of dual-frequency transducers for ultrasound internal imaging
- 21 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 113-117
A Study on Vessel Wall Shrinkage and Tissue Damage of Compressed Vascular Using Therapeutic Ultrasound
Abstract--Ultrasound therapy has been proven to be a method of ablating diseased blood vessels. Currently, experiments have proven that external pressure on the vascular region to be treated can effectively improve the success rate of closure. However, the degree of resulting thermal damage to surrounding tissue and the reason for the effects of compression on the shrinkage of tissue-encased blood vessels remain unclear. To address this issue, we conducted a study comparing the rate of shrinkage and surrounding tissue damage of compressed vessels encapsulated in muscle tissue to vessels with normal blood flow before and after treatment using the Simulation experiment and the ex-vivo tissue experiment. The results show that in the simulated model of compressed blood vessels with static blood flow, the temperature rise is significantly higher compared to the model with simulated blood flow. In the ex-vivo tissue experiment, the shrinkage rate of the blood vessel with static blood flow reaches up to 57% after the treatment, while the area of thermal damage is 28.8mm$^{2}$. In contrast, in the blood vessel with flowing blood, the vessels undergo almost no shrinkage but still cause 5.16mm$^{2}$ of thermal damage to the surrounding tissue. Our findings confirm that compressing the vessel is an effective and necessary step for the ultrasound closure of the vessel. But at the same time, to alleviate additional thermal damage, trying to change the way and position of the compression during treatment may be necessary.
- 21 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 113-117
A Study on Vessel Wall Shrinkage and Tissue Damage of Compressed Vascular Using Therapeutic Ultrasound
Abstract--Ultrasound therapy has been proven to be a method of ablating diseased blood vessels. Currently, experiments have proven that external pressure on the vascular region to be treated can effectively improve the success rate of closure. However, the degree of resulting thermal damage to surrounding tissue and the reason for the effects of compression on the shrinkage of tissue-encased blood vessels remain unclear. To address this issue, we conducted a study comparing the rate of shrinkage and surrounding tissue damage of compressed vessels encapsulated in muscle tissue to vessels with normal blood flow before and after treatment using the Simulation experiment and the ex-vivo tissue experiment. The results show that in the simulated model of compressed blood vessels with static blood flow, the temperature rise is significantly higher compared to the model with simulated blood flow. In the ex-vivo tissue experiment, the shrinkage rate of the blood vessel with static blood flow reaches up to 57% after the treatment, while the area of thermal damage is 28.8mm$^{2}$. In contrast, in the blood vessel with flowing blood, the vessels undergo almost no shrinkage but still cause 5.16mm$^{2}$ of thermal damage to the surrounding tissue. Our findings confirm that compressing the vessel is an effective and necessary step for the ultrasound closure of the vessel. But at the same time, to alleviate additional thermal damage, trying to change the way and position of the compression during treatment may be necessary.
- Open Access
- 18 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 5069
Study of a Novel High-Frequency Ultrasound-Guided Integrated System for Varicose Veins Ultrasound Therapy
Varicose veins in the lower limb are a common and progressive venous disorder that can significantly reduce patients’ quality of life and pose a threat to their overall health if left untreated. However, current treatment approaches often involve invasive intervention. High-intensity focused ultrasound (HIFU) technology has the potential to treat varicose veins non-invasively, but most systems are bulky and expensive. This study proposes an innovative, integrated system that uses a 4.5 MHz therapeutic probe guided by a 12 MHz ultrasound imaging probe to treat varicose veins in the lower limb. The system aims to achieve high accuracy in repeated treatments by using a high-speed scanning positioning structure, increasing the imaging framerate, and reducing the system’s overall volume. The system’s accuracy is evaluated through reset error tests on an acrylic board, and its effectiveness is tested through in vivo experiments on rabbit marginal ear veins. Tests on porcine arteries are conducted to identify suitable focal points for vascular treatment. The experimental results demonstrate the system’s high accuracy, with a reset error of less than 0.07 mm, and an obvious shrinkage of the predetermined treatment area of the marginal ear veins after therapy. The study identifies that setting the focus on the vascular wall can improve the efficiency of vascular treatment, resulting in significant vasoconstriction changes. These experimental findings provide sufficient evidence for the system’s potential for clinical application in vascular treatment.
- 18 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 5069
Open AccessStudy of a Novel High-Frequency Ultrasound-Guided Integrated System for Varicose Veins Ultrasound Therapy
Varicose veins in the lower limb are a common and progressive venous disorder that can significantly reduce patients’ quality of life and pose a threat to their overall health if left untreated. However, current treatment approaches often involve invasive intervention. High-intensity focused ultrasound (HIFU) technology has the potential to treat varicose veins non-invasively, but most systems are bulky and expensive. This study proposes an innovative, integrated system that uses a 4.5 MHz therapeutic probe guided by a 12 MHz ultrasound imaging probe to treat varicose veins in the lower limb. The system aims to achieve high accuracy in repeated treatments by using a high-speed scanning positioning structure, increasing the imaging framerate, and reducing the system’s overall volume. The system’s accuracy is evaluated through reset error tests on an acrylic board, and its effectiveness is tested through in vivo experiments on rabbit marginal ear veins. Tests on porcine arteries are conducted to identify suitable focal points for vascular treatment. The experimental results demonstrate the system’s high accuracy, with a reset error of less than 0.07 mm, and an obvious shrinkage of the predetermined treatment area of the marginal ear veins after therapy. The study identifies that setting the focus on the vascular wall can improve the efficiency of vascular treatment, resulting in significant vasoconstriction changes. These experimental findings provide sufficient evidence for the system’s potential for clinical application in vascular treatment.
- Open Access
- 26 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (6) , 612
Efficacy Estimation of Microbubble-Assisted Local Sonothrombolysis Using a Catheter with a Series of Miniature Transducers
Intravascular ultrasound has good prospects for clinical applications in sonothrombolysis. The catheter-based side-looking intravascular ultrasound thrombolysis (e.g., Ekosonic catheters) used in clinical studies has a high frequency (2 MHz). The lower-frequency ultrasound requires a larger-diameter transducer. In our study, we designed and manufactured a small ultrasound-based prototype catheter that can emit a lower frequency ultrasound (1.1 MHz). In order to evaluate the safety and efficacy of local low-frequency ultrasound-enhanced thrombolysis, a microbubble (MB) was introduced to augment thrombolysis effect of locally delivered low-intensity ultrasound. The results demonstrated that combination of ultrasound and MB realized higher clot lysis than urokinase-only treatment (17.0% ± 1.2% vs. 14.9% ± 2.7%) under optimal ultrasound settings of 1.1 MHz, 0.414 MPa, 4.89 W/cm2, 5% duty cycle and MB concentration of 60 μg/mL. When urokinase was added, the fibrinolysis accelerated by MB and ultrasound resulted in a further increased thrombolysis rate that was more than two times than that of urokinase alone (36.7% ± 5.5% vs. 14.9% ± 2.7%). However, a great quantity of ultrasound energy was required to achieve substantial clot lysis without MB, leading to the situation that temperature accumulated inside the clot became harmful. We suggest that MB-assisted local sonothrombolysis be considered as adjuvant therapy of thrombolytic agents.
- 26 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (6) , 612
Open AccessEfficacy Estimation of Microbubble-Assisted Local Sonothrombolysis Using a Catheter with a Series of Miniature Transducers
Intravascular ultrasound has good prospects for clinical applications in sonothrombolysis. The catheter-based side-looking intravascular ultrasound thrombolysis (e.g., Ekosonic catheters) used in clinical studies has a high frequency (2 MHz). The lower-frequency ultrasound requires a larger-diameter transducer. In our study, we designed and manufactured a small ultrasound-based prototype catheter that can emit a lower frequency ultrasound (1.1 MHz). In order to evaluate the safety and efficacy of local low-frequency ultrasound-enhanced thrombolysis, a microbubble (MB) was introduced to augment thrombolysis effect of locally delivered low-intensity ultrasound. The results demonstrated that combination of ultrasound and MB realized higher clot lysis than urokinase-only treatment (17.0% ± 1.2% vs. 14.9% ± 2.7%) under optimal ultrasound settings of 1.1 MHz, 0.414 MPa, 4.89 W/cm2, 5% duty cycle and MB concentration of 60 μg/mL. When urokinase was added, the fibrinolysis accelerated by MB and ultrasound resulted in a further increased thrombolysis rate that was more than two times than that of urokinase alone (36.7% ± 5.5% vs. 14.9% ± 2.7%). However, a great quantity of ultrasound energy was required to achieve substantial clot lysis without MB, leading to the situation that temperature accumulated inside the clot became harmful. We suggest that MB-assisted local sonothrombolysis be considered as adjuvant therapy of thrombolytic agents.