    Effect of Endostaple Configuration and Oversizing on Endograft Displacement Force: An In Vitro Evaluation of the Aortoseal Endostapling System

    by Stijn L. R. Pierie, Leendert-Jan W. Ligtenberg, D. Ben David, Islam S. M. Khalil, Jean-Paul P. M. de Vries

    Background: Proximal endograft fixation remains a key determinant of long-term durability of endovascular aortic repair (EVAR). The Aortoseal Endostapling system consists of a nitinol frame with 6 welded endostaples at the proximal end, intended to enhance fixation and seal of an endograft by mimicking the hand-sewn anastomosis of open aortic repair. This study evaluates the effect of different distributions of activated endostaples on endograft displacement force (EDF), while considering various endograft oversizing options. Methods: An in vitro silicone tube model was used to assess EDF at 2 mm endograft displacement and pull-out force across 11 activated staple configurations of the Aortoseal Endostapling system with 10%, 20%, and 30% endograft oversizing. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC), based on a 2-way mixed-effects model for absolute agreement. Results: Intraclass correlation coefficient for interobserver agreement was 0.987. Endograft displacement force ranged from 8.8 N ± 0.15 N to 39.6 N ± 2.96 N across all configurations and oversizing conditions. Incorporation of the Aortoseal frame alone, without staple activation, substantially increased EDF compared with no Aortoseal frame at 10% and 20% oversizing. Furthermore, EDF was mostly influenced by the number of activated staples and the maximum unstapled circumferential angle (MUCA). The 6-activated-staple configuration consistently yielded the highest EDF. The effect of oversizing on EDF was inconsistent across configurations at 10% and 20%, whereas 30% oversizing was associated with lower EDF in most configurations. Pull-out force exceeded EDF in all tested configurations except the 1-activated-staple configuration. Conclusion: In this in vitro study, Aortoseal frame incorporation alone substantially increased EDF relative to the graft-only configuration at 10% and 20% oversizing. Ten percent endograft oversizing yielded EDF values comparable with 20% oversizing across most configurations. Circumferential staple distribution was the primary determinant of EDF in the Aortoseal Endostapling system, with EDF decreasing with increasing MUCA and increasing with staple number across all endograft oversizing conditions, consistent with circumferential load sharing as a potential underlying mechanism. These findings may serve as a mechanistic reference framework for preoperative planning in anatomically challenging cases and warrant further experimental and clinical evaluation. Clinical Impact: The Aortoseal Endostapling system (Endoron Medical Holdings Ltd., Dublin, Ireland) represents a novel approach to proximal endograft fixation, enabling simultaneous circumferential single-stage activation of 6 nitinol endostaples via balloon activation, providing a uniform and reproducible fixation pattern intended to mimic the longitudinal and radial anchoring of a surgical anastomosis. To support clinical implementation, this study systematically evaluated endograft displacement force across a range of activated staple configurations, including suboptimal deployment scenarios. The findings provide physicians with a mechanistic reference framework for preoperative planning, supporting procedural decision-making in anatomically challenging cases.

  • Open Access

    Performance Estimation and Ex Vivo Validation of Untethered Magnetic Robots in Soft Tissue

    by Leendert‐Jan W. Ligtenberg, Thijs J. van der Burg, Stijn Y. Kolkman, Santiago Saavedra Castano, David Fernandez Rivas, Anke Klingner, Roger M. L. M. Lomme, Lucas S. Joziasse, Dorothee Wasserberg, H. Remco Liefers, et al.

    The navigation and control of untethered magnetic robots (UMRs) within soft brain tissue critically depend on their ability to maintain synchronized rotation under applied rotational magnetic fields. The fundamental upper limit of this magnetic synchronization, known as the step‐out frequency, directly affects propulsion efficiency and control stability. This study presents an empirical model for predicting the step‐out frequency of UMRs operating in ex vivo brain tissue with viscoelastic properties representative of the in vivo environment. Using Buckingham Pi dimensional analysis, we derive a compact set of dimensionless groups that capture the effects of robot geometry and tissue viscoelasticity, with magnetic torque used as the scaling basis. Experimental validation with spiral‐type UMRs in gelatin‐based phantoms shows that the step‐out frequency decreases exponentially, from approximately 30 Hz in low‐stiffness media (complex shear modulus 400 Pa) to below 1 Hz in high‐stiffness media (complex shear modulus 1600 Pa). The found relationship allows for rapid estimation of robot performance limits using a single calibration point, enabling efficient evaluation of robot design and actuation parameters. The resulting framework supports the clinical translation of magnetic microrobots for precise therapeutic and surgical interventions in brain tissue.


  • Open Access

    Swimming dynamics of screw-shaped untethered magnetic robots in confined spaces

    by Luuc de Jongh, Anke Klingner, Leendert-Jan W. Ligtenberg, Marcus C. J. de Boer, Jaap van der Kooij, Roger Lomme, Dorothee Wasserberg, H. Remco Liefers, Pascal Jonkheijm, Michiel C. Warlé, et al.

    In confined environments, the propulsion speed of torque-driven helical untethered magnetic robots (UMRs) depends on vessel diameter and helical pitch. This phenomenon likely affects the swimming speed of these robots when navigating in vivo within blood vessels. Achieving a consistent swimming speed across a range of vessel diameters is therefore essential for precise control of UMRs. With this goal, we investigate how vessel diameter and helical pitch influence UMR propulsion to identify optimal robot designs. UMRs from two groups–fixed length (FL) and fixed wave (FW)–were analyzed. In the FW group, longer robots achieved higher speeds in larger vessels due to better vessel guidance, whereas shorter robots performed best in medium-sized vessels. The FL group showed peak speeds at intermediate normalized wavenumbers ( $$\nu \approx 1$$ ν ≈ 1 to 1.8), significantly influenced by robot geometry and vessel confinement. Normalized wavenumber affected swimming speed and stability, with maximum efficiency at $$\nu \approx 1$$ ν ≈ 1 and stability increasing with higher wavenumbers. Swimming performance was modeled using Stokeslets method and additional effects were considered by correction factors to improve agreement of experimental and modeling results. Ex vivo tests under physiological conditions demonstrated clear performance differences between robust (FL-9 ( $$\nu =2.3$$ ν = 2.3 ), FW-5 ( $$\nu =2$$ ν = 2 )) and unstable swimmers, with robust designs showing consistent correlation between phantom and ex vivo trials. Unstable designs exhibited unpredictable behavior, emphasizing the importance of specific design parameters for stability and maneuverability. These findings highlight critical design factors–such as the normalized wavenumber, body length, and degree of vessel confinement–that are essential for enhancing UMR propulsion efficiency and control consistency, which are fundamental for successful navigation in targeted vascular biomedical applications.


  • Open Access

    Wireless mechanical and hybrid thrombus fragmentation of ex vivo endovascular thrombosis model in the iliac artery

    by Marcus C. J. de Boer, Leendert-Jan W. Ligtenberg, Iris Mulder, Constantinos Goulas, Anke Klingner, Roger Lomme, Emily A. M. Klein Rot, Dorothee Wasserberg, Yitong Lu, Remco Liefers, et al.

    This study investigates the efficacy of an untethered magnetic robot (UMR) for wireless mechanical and hybrid blood clot removal in ex vivo tissue environments. By integrating x-ray-guided wireless manipulation with UMRs, we aim to address challenges associated with precise and controlled blood clot intervention. The untethered nature and size of these robots enhance maneuverability and accessibility within complex vascular networks, potentially improving clot removal efficiency. We explore mechanical fragmentation, chemical lysis, and hybrid dissolution techniques that combine mechanical fragmentation with chemical lysis, highlighting their potential for targeted and efficient blood clot removal. Through experimental validation using an ex vivo endovascular thrombosis model within the iliac artery of a sheep, we demonstrate direct revascularization of a 13-mm-long, 1-day-old blood clot positioned inside the left common iliac artery. This was achieved by deploying a UMR into the abdominal aorta within 15 min. Additionally, both mechanical fragmentation and hybrid dissolution achieve a greater volume rate of change compared to no intervention (control) and chemical lysis alone. Mechanical fragmentation exhibits clot removal with a median of 0.87 mm3/min and a range of 2.81 mm3/min, while the hybrid approach demonstrates slower but more consistent clot removal, with a median of 0.45 mm3/min and a range of 0.23 mm3/min.


  • Open Access

    Author Correction: Ex vivo validation of magnetically actuated intravascular untethered robots in a clinical setting

    by Leendert-Jan W. Ligtenberg, Nicole C. A. Rabou, Constantinos Goulas, Wytze C. Duinmeijer, Frank R. Halfwerk, Jutta Arens, Roger Lomme, Veronika Magdanz, Anke Klingner, Emily A. M. Klein Rot, et al.

  • Open Access

    Ex vivo validation of magnetically actuated intravascular untethered robots in a clinical setting

    by Leendert-Jan W. Ligtenberg, Nicole C. A. Rabou, Constantinos Goulas, Wytze C. Duinmeijer, Frank R. Halfwerk, Jutta Arens, Roger Lomme, Veronika Magdanz, Anke Klingner, Emily A. M. Klein Rot, et al.

    Intravascular surgical instruments require precise navigation within narrow vessels, necessitating maximum flexibility, minimal diameter, and high degrees of freedom. Existing tools often lack control during insertion due to undesirable bending, limiting vessel accessibility and risking tissue damage. Next-generation instruments aim to develop hemocompatible untethered devices controlled by external magnetic forces. Achieving this goal remains complex due to testing and implementation challenges in clinical environments. Here we assess the operational effectiveness of hemocompatible untethered magnetic robots using an ex vivo porcine aorta model. The results demonstrate a linear decrease in the swimming speed of untethered magnetic robots as arterial blood flow increases, with the capability to navigate against a maximum arterial flow rate of 67 mL/min. The untethered magnetic robots effectively demonstrate locomotion in a difficult-to-access target site, navigating through the abdominal aorta and reaching the distal end of the renal artery.