H. Remco Liefers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
H. Remco Liefers has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Anke Klingner
Department of Physics, The German University in Cairo, Cairo, Egypt
3 shared publications - Dorothee Wasserberg
Laboratory of Biointerface Chemistry, Department of Molecules and Materials, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
3 shared publications - Islam S. M. Khalil
Robotics and Mechatronics Research Group, University of Twente, Enschede, The Netherlands
3 shared publications - Leendert-Jan W. Ligtenberg
Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands
3 shared publications - Michiel C. Warlé
Department of Surgery, Radboud University Medical Centre, Nijmegen, The Netherlands
3 shared publications - Pascal Jonkheijm
Laboratory of Biointerface Chemistry, Department of Molecules and Materials, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 14 August 2026
- Published by Wiley in Advanced Science
- Vol. 13 (61) , e77011
Performance Estimation and Ex Vivo Validation of Untethered Magnetic Robots in Soft Tissue
The navigation and control of untethered magnetic robots (UMRs) within soft brain tissue critically depend on their ability to maintain synchronized rotation under applied rotational magnetic fields. The fundamental upper limit of this magnetic synchronization, known as the step‐out frequency, directly affects propulsion efficiency and control stability. This study presents an empirical model for predicting the step‐out frequency of UMRs operating in ex vivo brain tissue with viscoelastic properties representative of the in vivo environment. Using Buckingham Pi dimensional analysis, we derive a compact set of dimensionless groups that capture the effects of robot geometry and tissue viscoelasticity, with magnetic torque used as the scaling basis. Experimental validation with spiral‐type UMRs in gelatin‐based phantoms shows that the step‐out frequency decreases exponentially, from approximately 30 Hz in low‐stiffness media (complex shear modulus 400 Pa) to below 1 Hz in high‐stiffness media (complex shear modulus 1600 Pa). The found relationship allows for rapid estimation of robot performance limits using a single calibration point, enabling efficient evaluation of robot design and actuation parameters. The resulting framework supports the clinical translation of magnetic microrobots for precise therapeutic and surgical interventions in brain tissue.
- 14 August 2026
- Published by Wiley in Advanced Science
- Vol. 13 (61) , e77011
Open AccessPerformance Estimation and Ex Vivo Validation of Untethered Magnetic Robots in Soft Tissue
The navigation and control of untethered magnetic robots (UMRs) within soft brain tissue critically depend on their ability to maintain synchronized rotation under applied rotational magnetic fields. The fundamental upper limit of this magnetic synchronization, known as the step‐out frequency, directly affects propulsion efficiency and control stability. This study presents an empirical model for predicting the step‐out frequency of UMRs operating in ex vivo brain tissue with viscoelastic properties representative of the in vivo environment. Using Buckingham Pi dimensional analysis, we derive a compact set of dimensionless groups that capture the effects of robot geometry and tissue viscoelasticity, with magnetic torque used as the scaling basis. Experimental validation with spiral‐type UMRs in gelatin‐based phantoms shows that the step‐out frequency decreases exponentially, from approximately 30 Hz in low‐stiffness media (complex shear modulus 400 Pa) to below 1 Hz in high‐stiffness media (complex shear modulus 1600 Pa). The found relationship allows for rapid estimation of robot performance limits using a single calibration point, enabling efficient evaluation of robot design and actuation parameters. The resulting framework supports the clinical translation of magnetic microrobots for precise therapeutic and surgical interventions in brain tissue.
- Open Access
- 11 August 2025
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 113 (21) , 29197-29213
Swimming dynamics of screw-shaped untethered magnetic robots in confined spaces
In confined environments, the propulsion speed of torque-driven helical untethered magnetic robots (UMRs) depends on vessel diameter and helical pitch. This phenomenon likely affects the swimming speed of these robots when navigating in vivo within blood vessels. Achieving a consistent swimming speed across a range of vessel diameters is therefore essential for precise control of UMRs. With this goal, we investigate how vessel diameter and helical pitch influence UMR propulsion to identify optimal robot designs. UMRs from two groups–fixed length (FL) and fixed wave (FW)–were analyzed. In the FW group, longer robots achieved higher speeds in larger vessels due to better vessel guidance, whereas shorter robots performed best in medium-sized vessels. The FL group showed peak speeds at intermediate normalized wavenumbers ( $$\nu \approx 1$$ to 1.8), significantly influenced by robot geometry and vessel confinement. Normalized wavenumber affected swimming speed and stability, with maximum efficiency at $$\nu \approx 1$$ and stability increasing with higher wavenumbers. Swimming performance was modeled using Stokeslets method and additional effects were considered by correction factors to improve agreement of experimental and modeling results. Ex vivo tests under physiological conditions demonstrated clear performance differences between robust (FL-9 ( $$\nu =2.3$$ ), FW-5 ( $$\nu =2$$ )) and unstable swimmers, with robust designs showing consistent correlation between phantom and ex vivo trials. Unstable designs exhibited unpredictable behavior, emphasizing the importance of specific design parameters for stability and maneuverability. These findings highlight critical design factors–such as the normalized wavenumber, body length, and degree of vessel confinement–that are essential for enhancing UMR propulsion efficiency and control consistency, which are fundamental for successful navigation in targeted vascular biomedical applications.- 11 August 2025
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 113 (21) , 29197-29213
Open AccessSwimming dynamics of screw-shaped untethered magnetic robots in confined spaces
In confined environments, the propulsion speed of torque-driven helical untethered magnetic robots (UMRs) depends on vessel diameter and helical pitch. This phenomenon likely affects the swimming speed of these robots when navigating in vivo within blood vessels. Achieving a consistent swimming speed across a range of vessel diameters is therefore essential for precise control of UMRs. With this goal, we investigate how vessel diameter and helical pitch influence UMR propulsion to identify optimal robot designs. UMRs from two groups–fixed length (FL) and fixed wave (FW)–were analyzed. In the FW group, longer robots achieved higher speeds in larger vessels due to better vessel guidance, whereas shorter robots performed best in medium-sized vessels. The FL group showed peak speeds at intermediate normalized wavenumbers ( $$\nu \approx 1$$ to 1.8), significantly influenced by robot geometry and vessel confinement. Normalized wavenumber affected swimming speed and stability, with maximum efficiency at $$\nu \approx 1$$ and stability increasing with higher wavenumbers. Swimming performance was modeled using Stokeslets method and additional effects were considered by correction factors to improve agreement of experimental and modeling results. Ex vivo tests under physiological conditions demonstrated clear performance differences between robust (FL-9 ( $$\nu =2.3$$ ), FW-5 ( $$\nu =2$$ )) and unstable swimmers, with robust designs showing consistent correlation between phantom and ex vivo trials. Unstable designs exhibited unpredictable behavior, emphasizing the importance of specific design parameters for stability and maneuverability. These findings highlight critical design factors–such as the normalized wavenumber, body length, and degree of vessel confinement–that are essential for enhancing UMR propulsion efficiency and control consistency, which are fundamental for successful navigation in targeted vascular biomedical applications. - Open Access
- 24 February 2025
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 12 (1)
Wireless mechanical and hybrid thrombus fragmentation of ex vivo endovascular thrombosis model in the iliac artery
This study investigates the efficacy of an untethered magnetic robot (UMR) for wireless mechanical and hybrid blood clot removal in ex vivo tissue environments. By integrating x-ray-guided wireless manipulation with UMRs, we aim to address challenges associated with precise and controlled blood clot intervention. The untethered nature and size of these robots enhance maneuverability and accessibility within complex vascular networks, potentially improving clot removal efficiency. We explore mechanical fragmentation, chemical lysis, and hybrid dissolution techniques that combine mechanical fragmentation with chemical lysis, highlighting their potential for targeted and efficient blood clot removal. Through experimental validation using an ex vivo endovascular thrombosis model within the iliac artery of a sheep, we demonstrate direct revascularization of a 13-mm-long, 1-day-old blood clot positioned inside the left common iliac artery. This was achieved by deploying a UMR into the abdominal aorta within 15 min. Additionally, both mechanical fragmentation and hybrid dissolution achieve a greater volume rate of change compared to no intervention (control) and chemical lysis alone. Mechanical fragmentation exhibits clot removal with a median of 0.87 mm3/min and a range of 2.81 mm3/min, while the hybrid approach demonstrates slower but more consistent clot removal, with a median of 0.45 mm3/min and a range of 0.23 mm3/min.
- 24 February 2025
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 12 (1)
Open AccessWireless mechanical and hybrid thrombus fragmentation of ex vivo endovascular thrombosis model in the iliac artery
This study investigates the efficacy of an untethered magnetic robot (UMR) for wireless mechanical and hybrid blood clot removal in ex vivo tissue environments. By integrating x-ray-guided wireless manipulation with UMRs, we aim to address challenges associated with precise and controlled blood clot intervention. The untethered nature and size of these robots enhance maneuverability and accessibility within complex vascular networks, potentially improving clot removal efficiency. We explore mechanical fragmentation, chemical lysis, and hybrid dissolution techniques that combine mechanical fragmentation with chemical lysis, highlighting their potential for targeted and efficient blood clot removal. Through experimental validation using an ex vivo endovascular thrombosis model within the iliac artery of a sheep, we demonstrate direct revascularization of a 13-mm-long, 1-day-old blood clot positioned inside the left common iliac artery. This was achieved by deploying a UMR into the abdominal aorta within 15 min. Additionally, both mechanical fragmentation and hybrid dissolution achieve a greater volume rate of change compared to no intervention (control) and chemical lysis alone. Mechanical fragmentation exhibits clot removal with a median of 0.87 mm3/min and a range of 2.81 mm3/min, while the hybrid approach demonstrates slower but more consistent clot removal, with a median of 0.45 mm3/min and a range of 0.23 mm3/min.
- Open Access
- 4 September 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (9) , 436
A Multimodality Myocardial Perfusion Phantom: Initial Quantitative Imaging Results
This proof-of-concept study explores the multimodal application of a dedicated cardiac flow phantom for ground truth contrast measurements in dynamic myocardial perfusion imaging with CT, PET/CT, and MRI. A 3D-printed cardiac flow phantom and flow circuit mimics the shape of the left ventricular cavity (LVC) and three myocardial regions. The regions are filled with tissue-mimicking materials and the flow circuit regulates and measures contrast flow through LVC and myocardial regions. Normal tissue perfusion and perfusion deficits were simulated. Phantom measurements in PET/CT, CT, and MRI were evaluated with clinically used hardware and software. The reference arterial input flow was 4.0 L/min and myocardial flow 80 mL/min, corresponding to myocardial blood flow (MBF) of 1.6 mL/g/min. The phantom demonstrated successful completion of all processes involved in quantitative, multimodal myocardial perfusion imaging (MPI) applications. Contrast kinetics in time intensity curves were in line with expectations for a mimicked perfusion deficit (38 s vs. 32 s in normal tissue). Derived MBF in PET/CT and CT led to under- and overestimation of reference flow of 0.9 mL/g/min and 4.5 mL/g/min, respectively. Simulated perfusion deficit (0.8 mL/g/min) in CT resulted in MBF of 2.8 mL/g/min. We successfully performed initial, quantitative perfusion measurements with a dedicated phantom setup utilizing clinical hardware and software. These results showcase the multimodal phantom’s potential.
- 4 September 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (9) , 436
Open AccessA Multimodality Myocardial Perfusion Phantom: Initial Quantitative Imaging Results
This proof-of-concept study explores the multimodal application of a dedicated cardiac flow phantom for ground truth contrast measurements in dynamic myocardial perfusion imaging with CT, PET/CT, and MRI. A 3D-printed cardiac flow phantom and flow circuit mimics the shape of the left ventricular cavity (LVC) and three myocardial regions. The regions are filled with tissue-mimicking materials and the flow circuit regulates and measures contrast flow through LVC and myocardial regions. Normal tissue perfusion and perfusion deficits were simulated. Phantom measurements in PET/CT, CT, and MRI were evaluated with clinically used hardware and software. The reference arterial input flow was 4.0 L/min and myocardial flow 80 mL/min, corresponding to myocardial blood flow (MBF) of 1.6 mL/g/min. The phantom demonstrated successful completion of all processes involved in quantitative, multimodal myocardial perfusion imaging (MPI) applications. Contrast kinetics in time intensity curves were in line with expectations for a mimicked perfusion deficit (38 s vs. 32 s in normal tissue). Derived MBF in PET/CT and CT led to under- and overestimation of reference flow of 0.9 mL/g/min and 4.5 mL/g/min, respectively. Simulated perfusion deficit (0.8 mL/g/min) in CT resulted in MBF of 2.8 mL/g/min. We successfully performed initial, quantitative perfusion measurements with a dedicated phantom setup utilizing clinical hardware and software. These results showcase the multimodal phantom’s potential.