Dimitri A. Madden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dimitri A. Madden has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Gregory S. Jackson
Department of Mechanical Engineering, Colorado School of Mines, Golden, Colorado 80401, United States of America
2 shared publications - Jesse R. Fosheim
Brayton Energy LLC
2 shared publications - Keaton J. Brewster
Colorado School of Mines
2 shared publications Kevin J. Albrecht
2 shared publications- Renkun Chen
Univ. of California, San Diego, CA (United States)
2 shared publications - Winfred J. Arthur-Arhin
Colorado School of Mines
2 shared publications
Latest Publications
- Open Access
- 5 June 2026
- Published by Elsevier in SSRN Electronic Journal
Thermo-mechanical Derating and Sensitization in the presence of Molten Salt
Nickel Alloys and Molten Chloride salts are the forefront of research for high temperature materials in power generation and advanced nuclear power systems. There exist Increasing interest in Molten Salt Reactors that use molten salt as a coolant or as a fuel, these reactors have been proven to operate with improved safeguards. Chloride Molten Salt’s properties make it a great heat transfer fluid (HTF) and it is an ideal candidate for Thermal Energy Storage (TES). These applications are faced with the challenges of material corrosion caused by the Molten Chloride Salt. Thermo-mechanical derating is especially relevant for next generation molten salt systems targeting ≥ 700 °C operation [1]. Sensitization is the development of chromium depleted grain boundary regions, often associated with carbide precipitation, that promote intergranular corrosion and cracking; it is commonly quantified using electrochemical reactivation metrics such as the DL‑EPR ratio Ir/Ia to determine the degree of sensitization (DOS), another method is measuring the carbon forming carbide to be greater than 0.008 wt% [2]. We examine how chloride molten salt drive selective element dissolution, notably Cr, porous depleted surface layers, and grain-boundary attack, with strong dependence on temperature, stress strain, exposure time, salt redox state, and oxygen water impurities. The paper’s objective is to establish a mechanistically grounded linkage between salt chemistry, impurity control, sensitization metrics (DoS, intergranular attack depth), and derating factors suitable for design and qualification testing.
- 5 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermo-mechanical Derating and Sensitization in the presence of Molten Salt
Nickel Alloys and Molten Chloride salts are the forefront of research for high temperature materials in power generation and advanced nuclear power systems. There exist Increasing interest in Molten Salt Reactors that use molten salt as a coolant or as a fuel, these reactors have been proven to operate with improved safeguards. Chloride Molten Salt’s properties make it a great heat transfer fluid (HTF) and it is an ideal candidate for Thermal Energy Storage (TES). These applications are faced with the challenges of material corrosion caused by the Molten Chloride Salt. Thermo-mechanical derating is especially relevant for next generation molten salt systems targeting ≥ 700 °C operation [1]. Sensitization is the development of chromium depleted grain boundary regions, often associated with carbide precipitation, that promote intergranular corrosion and cracking; it is commonly quantified using electrochemical reactivation metrics such as the DL‑EPR ratio Ir/Ia to determine the degree of sensitization (DOS), another method is measuring the carbon forming carbide to be greater than 0.008 wt% [2]. We examine how chloride molten salt drive selective element dissolution, notably Cr, porous depleted surface layers, and grain-boundary attack, with strong dependence on temperature, stress strain, exposure time, salt redox state, and oxygen water impurities. The paper’s objective is to establish a mechanistically grounded linkage between salt chemistry, impurity control, sensitization metrics (DoS, intergranular attack depth), and derating factors suitable for design and qualification testing.
- 24 December 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 239
Impact of Janssen effect on thermal transport in granular flow
- 24 December 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 239
Impact of Janssen effect on thermal transport in granular flow
- Open Access
- 16 December 2024
- Published by Office of Scientific and Technical Information (OSTI)
In‐operando thermal transport characterization of moving particle bed heat exchanger
The project aimed to develop modulated photothermal radiometry (MPR) for conducting in-operando measurements of thermal transport in moving particle bed heat exchangers (MPBE) located at Sandia National Laboratory (SNL). The plan was to initially conduct lab-scale measurements on a 1-meter-long particle channel at UCSD, followed by in- operando measurements at SNL on a 20 kWth MPBE prototype built for this project, and if time permitting, potential final deployment on SNL’s 1 MWth G3P3 MPBE. The first two goals were successfully achieved but due to changes with commissioning timeline of the G3P3 MPBE, in-operando measurements on the G3P3 MPBE could not be conducted. The measurement campaigns have resulted in some promising results and the MPR tool has been handed over to trained SNL personnel for future use. MPR measurements on UCSD’s 1-meter-long particle channel showed a peculiar length dependence of the particle bed thermal conductivity and near-wall thermal resistance. The bed thermal conductivity increased, and the near-wall thermal resistance decreased, with increasing distance from the channel inlet, both eventually reaching a plateau. This was found to be due to hydrostatic pressure screening by the channel walls, known as the “Janssen effect”, and is the first experimental study on its role in granular heat transfer. A 20 kWth small-scale MPBE prototype, the first of its kind with 3 mm particle channels and 2 mm sCO2 plates, was designed and manufactured by Vacuum Process Engineering (VPE) for this project. This MPBE prototype was installed in SNL’s HEX test stand and the MPR tool was integrated into the test stand for in-operando measurements. Several modifications have been made to the MPR setup for facile installation and easy operation at SNL. Measurements with Carbo HSP40/70 particles were conducted with various particle and sCO2 temperatures and flow rates. Further, apart from regular MPBE operation, fault scenarios such as plate warping, particle stagnation, and choking were also detected and MPR showed excellent sensitivity to the detection of such conditions. Through the course of this project, MPR has evolved from a sensitive laboratory technique to a rugged industrial tool with various applications in high temperature measurements and diagnostics.
- 16 December 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessIn‐operando thermal transport characterization of moving particle bed heat exchanger
The project aimed to develop modulated photothermal radiometry (MPR) for conducting in-operando measurements of thermal transport in moving particle bed heat exchangers (MPBE) located at Sandia National Laboratory (SNL). The plan was to initially conduct lab-scale measurements on a 1-meter-long particle channel at UCSD, followed by in- operando measurements at SNL on a 20 kWth MPBE prototype built for this project, and if time permitting, potential final deployment on SNL’s 1 MWth G3P3 MPBE. The first two goals were successfully achieved but due to changes with commissioning timeline of the G3P3 MPBE, in-operando measurements on the G3P3 MPBE could not be conducted. The measurement campaigns have resulted in some promising results and the MPR tool has been handed over to trained SNL personnel for future use. MPR measurements on UCSD’s 1-meter-long particle channel showed a peculiar length dependence of the particle bed thermal conductivity and near-wall thermal resistance. The bed thermal conductivity increased, and the near-wall thermal resistance decreased, with increasing distance from the channel inlet, both eventually reaching a plateau. This was found to be due to hydrostatic pressure screening by the channel walls, known as the “Janssen effect”, and is the first experimental study on its role in granular heat transfer. A 20 kWth small-scale MPBE prototype, the first of its kind with 3 mm particle channels and 2 mm sCO2 plates, was designed and manufactured by Vacuum Process Engineering (VPE) for this project. This MPBE prototype was installed in SNL’s HEX test stand and the MPR tool was integrated into the test stand for in-operando measurements. Several modifications have been made to the MPR setup for facile installation and easy operation at SNL. Measurements with Carbo HSP40/70 particles were conducted with various particle and sCO2 temperatures and flow rates. Further, apart from regular MPBE operation, fault scenarios such as plate warping, particle stagnation, and choking were also detected and MPR showed excellent sensitivity to the detection of such conditions. Through the course of this project, MPR has evolved from a sensitive laboratory technique to a rugged industrial tool with various applications in high temperature measurements and diagnostics.
- Open Access
- 20 November 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 2
Performance Evaluation of a 40-kWth Prototype Counterflow Particle-sCO2 Fluidized Bed Heat Exchanger
Particle-sCO2 heat exchangers (HXs) can couple particle-based thermal energy storage for concentrating solar power (CSP) plants with recompression closed Brayton power cycles (RCBC) to enable continuous dispatchable renewable electricity. RCBC firing temperatures >700°C require HXs with expensive Ni-based alloys, requiring HX designs to reduce mass with high overall heat transfer coefficients UHX to meet CSP primary HX cost. To enhance UHX, mild bubbling fluidization with downward particle flows and upward fluidizing gas flows can achieve particle-wall heat transfer coefficients hT,w >800 W m-2 K-1 with CARBOBEAD HSP 40/70. To assess how high hT,w with mild particle fluidization impacts UHX, a 40-kWth particle-sCO2 HX with 12-parallel narrow-channel fluidized beds was assembled and tested to particle inlet temperatures up to 530 °C. Tests show reliable steady-state HX operation by maintaining fluidized particles in a freeboard zone above the parallel channels, but axial dispersion mixes partially cooled particles up from the fluidized channels with particles fed into the freeboard zone from the feed hopper. This mixing lowers the effective bed temperatures and the driving force for heat transfer to counterflowing sCO2 in microchannelled walls. Measured UHX based on particle inlet temperature never exceeded 205 W m-2 K-1. The trade-off between increased hT,w, and increased vertical dispersion with gas flows resulted in only small improvements in UHX after the onset of fluidization. Dispersion was incorporated into HX design and performance models that used hT,w correlations fitted to single-channel heat transfer tests. Model results show that reducing dispersion leads to higher particle wall heat transfer.
- 20 November 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 2
Open AccessPerformance Evaluation of a 40-kWth Prototype Counterflow Particle-sCO2 Fluidized Bed Heat Exchanger
Particle-sCO2 heat exchangers (HXs) can couple particle-based thermal energy storage for concentrating solar power (CSP) plants with recompression closed Brayton power cycles (RCBC) to enable continuous dispatchable renewable electricity. RCBC firing temperatures >700°C require HXs with expensive Ni-based alloys, requiring HX designs to reduce mass with high overall heat transfer coefficients UHX to meet CSP primary HX cost. To enhance UHX, mild bubbling fluidization with downward particle flows and upward fluidizing gas flows can achieve particle-wall heat transfer coefficients hT,w >800 W m-2 K-1 with CARBOBEAD HSP 40/70. To assess how high hT,w with mild particle fluidization impacts UHX, a 40-kWth particle-sCO2 HX with 12-parallel narrow-channel fluidized beds was assembled and tested to particle inlet temperatures up to 530 °C. Tests show reliable steady-state HX operation by maintaining fluidized particles in a freeboard zone above the parallel channels, but axial dispersion mixes partially cooled particles up from the fluidized channels with particles fed into the freeboard zone from the feed hopper. This mixing lowers the effective bed temperatures and the driving force for heat transfer to counterflowing sCO2 in microchannelled walls. Measured UHX based on particle inlet temperature never exceeded 205 W m-2 K-1. The trade-off between increased hT,w, and increased vertical dispersion with gas flows resulted in only small improvements in UHX after the onset of fluidization. Dispersion was incorporated into HX design and performance models that used hT,w correlations fitted to single-channel heat transfer tests. Model results show that reducing dispersion leads to higher particle wall heat transfer.