Galina V. Presnova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Galina V. Presnova has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Mayya Yu. Rubtsova
Faculty of Chemistry, Lomonosov Moscow State University, Moscow, Russia
3 shared publications - A. D. Usvaliev
Faculty of Chemistry, Lomonosov Moscow State University, Moscow, Russian Federation
1 shared publication A.A. Skorik
1 shared publication- Aleksandra M. Rozhkova
Federal Research Centre «Fundamentals of Biotechnology» of the Russian Academy of Sciences, Moscow 119071, Russia
1 shared publication - Alexander A. Baykov
Belozersky Institute of Physico-Chemical Biology, Lomonosov Moscow State University, Moscow 119899, Russia
1 shared publication - Alexander P. Osipov
Faculty of Chemistry, Lomonosov Moscow State University, Moscow, Russia
1 shared publication
Latest Publications
- 1 December 2024
- Published by Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii in Russian Chemical Reviews
- Vol. 93 (12) , RCR5144
Biocatalysis: modern challenges and applications
The review analyzes recent advances, challenges, and practical applications in the field of enzymes within the framework of chemical enzymology and enzyme engineering. The achievements in the fundamental understanding of molecular mechanisms of the catalytic cycle of enzymatic reactions made using quantum mechanics/molecular mechanics methods with supercomputer technologies and bioinformatic approaches are considered. The design of protein biocatalysts with new properties is a fundamentally significant methodology of the bioengineering approach to solving practical problems, which is demonstrated by a number of examples. The increasing role of biocatalysis in medicine and biomedical research is illustrated by addressing the problems of antibiotic synthesis and overcoming antibiotic resistance of bacteria, mechanisms of neurodegenerative diseases and development of drugs to treat Alzheimer's disease, biocatalytic processes of DNA repair and the role of mechanisms of functioning of heme peroxidases in the human body. The use of enzymes to degrade endogenous and exogenous toxicants has been greatly developed in recent decades. The advances and problems of using enzymes in therapy and drug delivery are analyzed. The fundamental role of enzymes in modern analysis and diagnosis is noted. The review considers a new trend in the development of bioanalytical methods using aptamers, multi-analysis systems on biochips, surface-enhanced Raman scattering systems, and bioelectroanalysis. The bibliography includes 460 references.
- 1 December 2024
- Published by Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii in Russian Chemical Reviews
- Vol. 93 (12) , RCR5144
Biocatalysis: modern challenges and applications
The review analyzes recent advances, challenges, and practical applications in the field of enzymes within the framework of chemical enzymology and enzyme engineering. The achievements in the fundamental understanding of molecular mechanisms of the catalytic cycle of enzymatic reactions made using quantum mechanics/molecular mechanics methods with supercomputer technologies and bioinformatic approaches are considered. The design of protein biocatalysts with new properties is a fundamentally significant methodology of the bioengineering approach to solving practical problems, which is demonstrated by a number of examples. The increasing role of biocatalysis in medicine and biomedical research is illustrated by addressing the problems of antibiotic synthesis and overcoming antibiotic resistance of bacteria, mechanisms of neurodegenerative diseases and development of drugs to treat Alzheimer's disease, biocatalytic processes of DNA repair and the role of mechanisms of functioning of heme peroxidases in the human body. The use of enzymes to degrade endogenous and exogenous toxicants has been greatly developed in recent decades. The advances and problems of using enzymes in therapy and drug delivery are analyzed. The fundamental role of enzymes in modern analysis and diagnosis is noted. The review considers a new trend in the development of bioanalytical methods using aptamers, multi-analysis systems on biochips, surface-enhanced Raman scattering systems, and bioelectroanalysis. The bibliography includes 460 references.
- 25 May 2024
- Published by Springer Nature in Veterinary Research Communications
- Vol. 48 (4) , 2805-2811
Multiplex gradient immunochip for detection of post-vaccinal antibodies in poultry
Multiplex analysis as an immunochip-in-a well format for simultaneous detection of post-vaccinal antibodies to three poultry infections (Newcastle disease, infectious bronchitis and bursal disease) in one chicken sera was developed. The immunochip had a microarray format printed on the bottom of a standard microtiter plate well and consisted of 36 microspots (d = 400 μm each) with three lines of viral antigens absorbed in a gradient of five decreasing concentrations. Optimization of assay conditions revealed the necessity of careful choice of the reaction buffer due to the high tendency of chicken IgY to exhibit unspecific binding. The best results were obtained for PBS buffer (pH 6.0) supplied with 0.1% Tween 20. Assay results were visualized by a number of coloured microspots that were correlated with the specific antibody titre in the analysed serum. High (> 8000), medium (3000–8000) or low (1000–3000) antibody titre level for each of three infections could be quickly assessed in one probe visually or with the help of smartphone. ELISA results (antibody titres) and visual gradient immunochip results interpretation (high, medium, low antibody level/titre) for 63 chicken sera with multiple levels of post-vaccinal antibodies against Newcastle disease, infectious bronchitis and bursal disease were in good correlation.
- 25 May 2024
- Published by Springer Nature in Veterinary Research Communications
- Vol. 48 (4) , 2805-2811
Multiplex gradient immunochip for detection of post-vaccinal antibodies in poultry
Multiplex analysis as an immunochip-in-a well format for simultaneous detection of post-vaccinal antibodies to three poultry infections (Newcastle disease, infectious bronchitis and bursal disease) in one chicken sera was developed. The immunochip had a microarray format printed on the bottom of a standard microtiter plate well and consisted of 36 microspots (d = 400 μm each) with three lines of viral antigens absorbed in a gradient of five decreasing concentrations. Optimization of assay conditions revealed the necessity of careful choice of the reaction buffer due to the high tendency of chicken IgY to exhibit unspecific binding. The best results were obtained for PBS buffer (pH 6.0) supplied with 0.1% Tween 20. Assay results were visualized by a number of coloured microspots that were correlated with the specific antibody titre in the analysed serum. High (> 8000), medium (3000–8000) or low (1000–3000) antibody titre level for each of three infections could be quickly assessed in one probe visually or with the help of smartphone. ELISA results (antibody titres) and visual gradient immunochip results interpretation (high, medium, low antibody level/titre) for 63 chicken sera with multiple levels of post-vaccinal antibodies against Newcastle disease, infectious bronchitis and bursal disease were in good correlation.
- 2 June 2023
- Published by Moscow University Press in Vestnik Moskovskogo Universiteta, Seriya 3: Fizika, Astronomiya
- No. №2_2023
Nanoscale biosensor with integratedthermoregulation controller for DNA diagnostics.
We present a CMOS compatible technique for fabrication a sensor system based on field-effect transistors with a nanowire channel with an integrated thermoregulation elements. The proposed system provides the necessary temperature regimes for many bioanalytical studies. Field-effect transistors with a nanowire channel were fabricated using of reactive-ion etching of the upper layer of a silicon on insulator through a mask formed by electron beam lithography. Titanium thermoresistive strips for temperature control were located on the surface of the chip nearby to the nanowire transistors. Their fabrication is carried out simultaneously with the formation of contact pads to the transistor electrodes, which made it possible to avoid additional technological steps. A demonstration of a system with a built-in temperature controller for the determination of nucleic acids was carried out on model oligonucleotides. Increasing the operating temperature of the device to the ranges at which DNA hybridization occurs most efficiently allows increasing specificity and avoiding false positive results, as well as reducing analysis time. The possibility of heating up to 85–90∘C allows you to reuse such devices.
- 2 June 2023
- Published by Moscow University Press in Vestnik Moskovskogo Universiteta, Seriya 3: Fizika, Astronomiya
- No. №2_2023
Nanoscale biosensor with integratedthermoregulation controller for DNA diagnostics.
We present a CMOS compatible technique for fabrication a sensor system based on field-effect transistors with a nanowire channel with an integrated thermoregulation elements. The proposed system provides the necessary temperature regimes for many bioanalytical studies. Field-effect transistors with a nanowire channel were fabricated using of reactive-ion etching of the upper layer of a silicon on insulator through a mask formed by electron beam lithography. Titanium thermoresistive strips for temperature control were located on the surface of the chip nearby to the nanowire transistors. Their fabrication is carried out simultaneously with the formation of contact pads to the transistor electrodes, which made it possible to avoid additional technological steps. A demonstration of a system with a built-in temperature controller for the determination of nucleic acids was carried out on model oligonucleotides. Increasing the operating temperature of the device to the ranges at which DNA hybridization occurs most efficiently allows increasing specificity and avoiding false positive results, as well as reducing analysis time. The possibility of heating up to 85–90∘C allows you to reuse such devices.