Mir Khadiza Akter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Mir Khadiza Akter has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ji Chen
University of Houston
3 shared publications - Jianfeng Zheng
Department of Electrical and Computer Engineering University of Houston Houston Texas USA
2 shared publications - Wolfgang Kainz
High Performance Computing for MRI Safety, Jasper, GA, USA
2 shared publications Ananda Kumar
Food and Drug Administration White Oak Campus, New Hampshire Ave Silver Spring, White Oak, MD, USA
1 shared publicationAo Shen
University of Houston
1 shared publicationFarshad Ebrahimi
Department of Electrical and Computer Engineering, University of Houston, Houston, TX, USA
1 shared publication
Latest Publications
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 68 (2) , 282-290
Numerical and Experimental Study on Mixed Use of Implantable Pulse Generator for AIMDs Under 1.5T MRI
Magnetic resonance imaging (MRI) safety for active implantable medical devices (AIMDs) can be compromised by radiofrequency-induced heating and voltage rectification, both of which are affected by the impedance of the implantable pulse generator (ZIPG). However, the influence of ZIPG on these safety mechanisms has not been systematically characterized. This article applied the transfer function (TF) approach to quantify how varying ZIPG values impact AIMD heating and voltage behavior. A mock implantable pulse generator (IPG) and a commercially available lead were tested across five impedance configurations using TF measurements and electromagnetic simulations with anatomically realistic human models. The results showed that voltage TFs maintained consistent shapes, but exhibited linearly increased (up to 50%) magnitudes with higher ZIPG, indicating a greater risk of voltage rectification and potential device malfunction. In contrast, heating TFs remained stable when the ratio of lead characteristic impedance to ZIPG was small. These findings demonstrate that IPG impedance can significantly influence AIMD responses in MRI environments and underscore the need for individualized evaluation of IPG interchangeability to ensure safe clinical use.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 68 (2) , 282-290
Numerical and Experimental Study on Mixed Use of Implantable Pulse Generator for AIMDs Under 1.5T MRI
Magnetic resonance imaging (MRI) safety for active implantable medical devices (AIMDs) can be compromised by radiofrequency-induced heating and voltage rectification, both of which are affected by the impedance of the implantable pulse generator (ZIPG). However, the influence of ZIPG on these safety mechanisms has not been systematically characterized. This article applied the transfer function (TF) approach to quantify how varying ZIPG values impact AIMD heating and voltage behavior. A mock implantable pulse generator (IPG) and a commercially available lead were tested across five impedance configurations using TF measurements and electromagnetic simulations with anatomically realistic human models. The results showed that voltage TFs maintained consistent shapes, but exhibited linearly increased (up to 50%) magnitudes with higher ZIPG, indicating a greater risk of voltage rectification and potential device malfunction. In contrast, heating TFs remained stable when the ratio of lead characteristic impedance to ZIPG was small. These findings demonstrate that IPG impedance can significantly influence AIMD responses in MRI environments and underscore the need for individualized evaluation of IPG interchangeability to ensure safe clinical use.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 172078-172084
Effect of Orthopedic Plate Length on Peripheral Nerve Stimulation During MRI: Combined Gradient-Induced and RF-Thermal Effects
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 172078-172084
Open AccessEffect of Orthopedic Plate Length on Peripheral Nerve Stimulation During MRI: Combined Gradient-Induced and RF-Thermal Effects
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 66 (4) , 1041-1056
Effect of Strain Relief Loop Position on the RF-Induced Heating of Active Implantable Medical Devices at 1.5-T MRI
This article studies the impact of strain relief loops on RF-induced heating of active implantable medical devices (AIMDs) during magnetic resonance imaging (MRI) scans at 1.5 T. Two commercially available AIMDs, a 40-cm lead length peripheral nerve stimulator (PNS) and a 60-cm lead length spinal cord stimulator (SCS), were utilized. In the in vitro study, lead-tip heating was calculated using the transfer function (TF) method and compared to direct measurement results for strain relief loops at various locations. In the human model analysis, RF-induced heating along six PNS and two SCS trajectories within the Duke, Ella, and FATS models was evaluated for strain relief loops positioned at various locations along the implantation trajectories. From the in vitro study, we can see up to a 48.3% reduction in the overall lead-tip heating. Inappropriate placement may result in doubled temperature rises. Significant temperature rise variation (up to 9°C) is observed with loop position, loop diameter, number of turns, and patient landmark. Differentiation of cumulative summation analysis is necessary to comprehend the strain relief loop's effect on RF-induced heating. The findings suggest that strategically placing the loop can effectively mitigate RF-induced heating for AIMDs exposed to 1.5-T MR environments.
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 66 (4) , 1041-1056
Effect of Strain Relief Loop Position on the RF-Induced Heating of Active Implantable Medical Devices at 1.5-T MRI
This article studies the impact of strain relief loops on RF-induced heating of active implantable medical devices (AIMDs) during magnetic resonance imaging (MRI) scans at 1.5 T. Two commercially available AIMDs, a 40-cm lead length peripheral nerve stimulator (PNS) and a 60-cm lead length spinal cord stimulator (SCS), were utilized. In the in vitro study, lead-tip heating was calculated using the transfer function (TF) method and compared to direct measurement results for strain relief loops at various locations. In the human model analysis, RF-induced heating along six PNS and two SCS trajectories within the Duke, Ella, and FATS models was evaluated for strain relief loops positioned at various locations along the implantation trajectories. From the in vitro study, we can see up to a 48.3% reduction in the overall lead-tip heating. Inappropriate placement may result in doubled temperature rises. Significant temperature rise variation (up to 9°C) is observed with loop position, loop diameter, number of turns, and patient landmark. Differentiation of cumulative summation analysis is necessary to comprehend the strain relief loop's effect on RF-induced heating. The findings suggest that strategically placing the loop can effectively mitigate RF-induced heating for AIMDs exposed to 1.5-T MR environments.