DJDengpei Ji

Dengpei Ji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dengpei Ji has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Xiaolin Xiao

    Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China

    2 shared publications
  • Dong Ming

    Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People’s Republic of China

    1 shared publication
  • Dong Ming

    Tianjin University

    1 shared publication
  • Guiying Zhang

    College of Science, Zhejiang University of Technology, Hangzhou, Zhejiang, People’s Republic of China

    1 shared publication
  • Jieyu Wu

    Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People’s Republic of China

    1 shared publication
  • Junyang Wang

    Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China

    1 shared publication

Latest Publications

  • Open Access

    Enhanced Spatial Division Multiple Access BCI Performance via Incorporating MEG With EEG

    by Dengpei Ji, Yongzhi Huang, Zhiyuan Chen, Xiaoyu Zhou, Junyang Wang, Xiaolin Xiao, Minpeng Xu, Dong Ming

    Spatial division multiple access (SDMA) is a way of encoding BCI systems based on spatial distribution of brain signal characteristics. However, SDMA-BCI based on EEG had poor system performance limited by spatial resolution. MEG-EEG fusion modality analysis can help solve this problem. According retina-cortical relationship, this study used stimulus out of the central visual field and tiny fixation points to construct a 16-command SDMA coded MEG-EEG fusion modality BCI system. We achieved this by synchronously acquiring MEG and EEG signals from 10 subjects. We compared the spatiotemporal features between MEG and EEG by analyzing signals in the occipital region. We fused MEG and EEG modalities without any signal processing and used the multi-class discriminative canonical pattern matching (Multi-DCPM) algorithm to evaluate and compare the system performance of EEG, MEG, and MEG-EEG fusion modalities. The result showed that MEG and EEG had obvious differences in spatial distribution characteristics. MEG improves offline classification accuracy of the 16 fixation points by 27.81% over EEG at 4s data length. Specially, the MEG-EEG fusion modality achieves an impressive average offline accuracy of 91.71%, which was a significant improvement over MEG (p<0.01, ANOVA). The MEG-EEG fusion modality achieved average information transfer rate (ITR) of 60.74 bits/min with a data length of 1 s, which was a 14% improvement over MEG. The MEG-EEG fusion modality significantly enhanced the spatial features and performance of SDMA-encoded BCIs. These results highlight the potential and feasibility of MEG-EEG fusion modality BCI, and provide theoretical insights and practical value for promoting the further development and application of SDMA in BCI.


  • A user-friendly visual brain-computer interface based on high-frequency steady-state visual evoked fields recorded by OPM-MEG

    by Dengpei Ji, Xiaolin Xiao, Jieyu Wu, Xiang He, Guiying Zhang, Ruihan Guo, Miao Liu, Minpeng Xu, Qiang Lin, Tzyy-Ping Jung, et al.

    Objective. Magnetoencephalography (MEG) shares a comparable time resolution with electroencephalography. However, MEG excels in spatial resolution, enabling it to capture even the subtlest and weakest brain signals for brain-computer interfaces (BCIs). Leveraging MEG’s capabilities, specifically with optically pumped magnetometers (OPM-MEG), proves to be a promising avenue for advancing MEG-BCIs, owing to its exceptional sensitivity and portability. This study harnesses the power of high-frequency steady-state visual evoked fields (SSVEFs) to build an MEG-BCI system that is flickering-imperceptible, user-friendly, and highly accurate. Approach. We have constructed a nine-command BCI that operates on high-frequency SSVEF (58–62 Hz with a 0.5 Hz interval) stimulation. We achieved this by placing the light source inside and outside the magnetic shielding room, ensuring compliance with non-magnetic and visual stimulus presentation requirements. Five participants took part in offline experiments, during which we collected six-channel multi-dimensional MEG signals along both the vertical (Z-axis) and tangential (Y-axis) components. Our approach leveraged the ensemble task-related component analysis algorithm for SSVEF identification and system performance evaluation. Main Results. The offline average accuracy of our proposed system reached an impressive 92.98% when considering multi-dimensional conjoint analysis using data from both the Z and Y axes. Our method achieved a theoretical average information transfer rate (ITR) of 58.36 bits min−1 with a data length of 0.7 s, and the highest individual ITR reached an impressive 63.75 bits min−1. Significance. This study marks the first exploration of high-frequency SSVEF-BCI based on OPM-MEG. These results underscore the potential and feasibility of MEG in detecting subtle brain signals, offering both theoretical insights and practical value in advancing the development and application of MEG in BCI systems.