Chuanxiang Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chuanxiang Zhu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kai Xu
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Xiang Wang
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Haomin Kuang
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Baibo Wu
Shanghai Jiao Tong University School of Mechanical Engineering 800 Dongchuan Road, Shanghai 200240 , China
1 shared publication - Chen Zhao
Parallel Robot and Mechatronic System Laboratory of Hebei Province, School of Mechanical Engineering, Yanshan University, Qinhuangdao, Hebei, China
1 shared publication - Lingyun Zeng
School of Biomedical Engineering and Imaging Sciences, Kings College London, London, U.K.
1 shared publication
Latest Publications
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (5) , 4396-4403
Closed-Loop Cooperative Manipulation of Deformable Tissue via Visual Feedback Using Multiple Continuum Surgical Manipulators
Continuum surgical manipulators exhibit promising potential in single-port laparoscopy due to their dexterity and design compactness. However, it is challenging for one continuum surgical manipulator to handle heavy tissues during a procedure. This letter hence proposes a closed-loop pose control framework that allows cooperative manipulation of deformable tissues using multiple continuum manipulators, leveraging the inherent visual feedback of a surgical robotic system. In the proposed control framework, the continuum manipulators and the deformable tissues that are gripped by the manipulators are firstly treated as a parallel continuum kinematic chain. The deformable tissues are simplified as elastic tissue rods to facilitate the derivation of a kinetostatics model for the parallel continuum kinematic chain based on the Cosserat rod theory. A stiffness and external wrench estimator and an inverse kinetostatics solver are then developed and utilized alternatively and iteratively in each control cycle. The effectiveness of the proposed control framework is verified through multiple experimental studies on a single-port endoscopic surgical system.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (5) , 4396-4403
Closed-Loop Cooperative Manipulation of Deformable Tissue via Visual Feedback Using Multiple Continuum Surgical Manipulators
Continuum surgical manipulators exhibit promising potential in single-port laparoscopy due to their dexterity and design compactness. However, it is challenging for one continuum surgical manipulator to handle heavy tissues during a procedure. This letter hence proposes a closed-loop pose control framework that allows cooperative manipulation of deformable tissues using multiple continuum manipulators, leveraging the inherent visual feedback of a surgical robotic system. In the proposed control framework, the continuum manipulators and the deformable tissues that are gripped by the manipulators are firstly treated as a parallel continuum kinematic chain. The deformable tissues are simplified as elastic tissue rods to facilitate the derivation of a kinetostatics model for the parallel continuum kinematic chain based on the Cosserat rod theory. A stiffness and external wrench estimator and an inverse kinetostatics solver are then developed and utilized alternatively and iteratively in each control cycle. The effectiveness of the proposed control framework is verified through multiple experimental studies on a single-port endoscopic surgical system.
- 26 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (11) , 10002-10009
Proof-of-Concept Development of the Distal Module of a Cystoscope Transurethral Continuum Surgical Robotic System
Transurethral resection of bladder tumor (TURBT) is the typical procedure for non-muscle invasive bladder tumors. However, current TURBT using rigid surgical tools can hardly handle en bloc resection of bladder tumor and anterior tumor resection. This letter hence proposes a teleoperation-based cystoscope transurethral continuum surgical robotic system and conducts proof-of-concept development of its distal module. The distal module uses a parallel continuum robot (PCR) form to fully utilize the urethra cross section as well as realize marker-less visual closed-loop control. The design of the distal module starts with a topology optimization of the PCR. Then, the PCR is modeled and optimized for better structural stiffness. Besides, the use of the PCR can inherently facilitate marker-less visual closed-loop control since its mobile platform has a toroidal shape that is easily identifiable in the endoscopic image based on the contour detection algorithm. The functionality of the distal module is evaluated via the experiments on a proof-of-concept construction. The distal module can grip the bladder mucosa and perform tumor resection with a bipolar loop under teleoperation. The experimental results showed that the 3-DoF (Degree of Freedom) distal module with an outer diameter of 7 mm realized a functional workspace volume of a φ 25-mm sphere and an average position error of 0.40 mm under closed-loop control. The teleoperation with closed-loop and open-loop control transition demonstrates a great potential for en bloc tumor resection.
- 26 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (11) , 10002-10009
Proof-of-Concept Development of the Distal Module of a Cystoscope Transurethral Continuum Surgical Robotic System
Transurethral resection of bladder tumor (TURBT) is the typical procedure for non-muscle invasive bladder tumors. However, current TURBT using rigid surgical tools can hardly handle en bloc resection of bladder tumor and anterior tumor resection. This letter hence proposes a teleoperation-based cystoscope transurethral continuum surgical robotic system and conducts proof-of-concept development of its distal module. The distal module uses a parallel continuum robot (PCR) form to fully utilize the urethra cross section as well as realize marker-less visual closed-loop control. The design of the distal module starts with a topology optimization of the PCR. Then, the PCR is modeled and optimized for better structural stiffness. Besides, the use of the PCR can inherently facilitate marker-less visual closed-loop control since its mobile platform has a toroidal shape that is easily identifiable in the endoscopic image based on the contour detection algorithm. The functionality of the distal module is evaluated via the experiments on a proof-of-concept construction. The distal module can grip the bladder mucosa and perform tumor resection with a bipolar loop under teleoperation. The experimental results showed that the 3-DoF (Degree of Freedom) distal module with an outer diameter of 7 mm realized a functional workspace volume of a φ 25-mm sphere and an average position error of 0.40 mm under closed-loop control. The teleoperation with closed-loop and open-loop control transition demonstrates a great potential for en bloc tumor resection.
- 8 March 2023
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 15 (3) , 1-24
Kinetostatic Modeling of Continuum Delta Robot With Variable Curvature Continuum Joints
Continuum robots have attracted lots of attention due to their structural compliance, manipulation dexterity, and design compactness. To extend the application scenarios, a slender continuum robot, the CurviPicker, was developed for low-load medium-speed pick-and-place tasks in a previous study. To improve the payload capacity and positioning accuracy of the CurviPicker, a novel Continuum Delta Robot (CDR) was then proposed with three dual-continuum-joint translators in a preliminary investigation. However, the initial version of the CDR did not fully utilize the bending ranges of its continuum joints. What's more, while being modeled using the constant curvature assumption for the continuum joints, the CDR shows lowered positioning accuracy for heavier objects, as the CDR's continuum joints diverge from the assumed constant curvature shapes. In this paper, the design of the CDR was re-optimized to enable wider bending ranges of the continuum joints (> 90 °) to generate enlarged workspace, taking into considerations several possible structural interferences. Furthermore, a kinetostatic model is derived based on the Cosserat rod theory to reduce the positioning errors caused by the external loads. The experimental result showed that the workspace is enlarged to approximately 9.47 × 107 mm3 compared with the volume of 6.57 × 107 mm3 of the initial version. Within this enlarged workspace, the average positioning error with a 1000-gram load was reduced to 1.93 mm, compared with 4.43 mm obtained by the previous constant curvature assumption.
- 8 March 2023
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 15 (3) , 1-24
Kinetostatic Modeling of Continuum Delta Robot With Variable Curvature Continuum Joints
Continuum robots have attracted lots of attention due to their structural compliance, manipulation dexterity, and design compactness. To extend the application scenarios, a slender continuum robot, the CurviPicker, was developed for low-load medium-speed pick-and-place tasks in a previous study. To improve the payload capacity and positioning accuracy of the CurviPicker, a novel Continuum Delta Robot (CDR) was then proposed with three dual-continuum-joint translators in a preliminary investigation. However, the initial version of the CDR did not fully utilize the bending ranges of its continuum joints. What's more, while being modeled using the constant curvature assumption for the continuum joints, the CDR shows lowered positioning accuracy for heavier objects, as the CDR's continuum joints diverge from the assumed constant curvature shapes. In this paper, the design of the CDR was re-optimized to enable wider bending ranges of the continuum joints (> 90 °) to generate enlarged workspace, taking into considerations several possible structural interferences. Furthermore, a kinetostatic model is derived based on the Cosserat rod theory to reduce the positioning errors caused by the external loads. The experimental result showed that the workspace is enlarged to approximately 9.47 × 107 mm3 compared with the volume of 6.57 × 107 mm3 of the initial version. Within this enlarged workspace, the average positioning error with a 1000-gram load was reduced to 1.93 mm, compared with 4.43 mm obtained by the previous constant curvature assumption.