Sthephane Pereira de Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sthephane Pereira de Oliveira has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Arnaldo César Pereira
Universidade Federal de São João del-Rei
3 shared publications - Daniela Nunes da Silva
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Thaís Cristina de Oliveira Cândido
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Esdras Gabriel Rodrigues Sales
Universidade Federal de São João del-Rei
1 shared publication - Gabriel Mendonça Piazzi
Universidade Federal de São João del-Rei
1 shared publication - Larissa Cristina de Souza
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
1 shared publication
Latest Publications
- 26 August 2025
- Published by Springer Nature
- p. 99-105
Biochemical Characterization and Application of Amylase from the Fungus Acremonium zeae in the Hydrolysis of Animal Feed
- 26 August 2025
- Published by Springer Nature
- p. 99-105
Biochemical Characterization and Application of Amylase from the Fungus Acremonium zeae in the Hydrolysis of Animal Feed
- Open Access
Development of Novel Conductive Inks for Screen-Printed Electrochemical Sensors: Enhancing Rapid and Sensitive Drug Detection
The development of screen-printed electrochemical sensors represents a rapidly expanding research field with great potential for applications in the rapid and sensitive determination of drugs in complex matrices. This work presents a review of the state-of-the-art examples of this technology, focusing on its application in real matrices such as water, pharmaceutical formulations, and biological fluids. We discuss the main materials used in developing conductive inks, highlighting their properties and influence on sensor performance. The characterization of materials and sensors is crucial to ensure the reproducibility and reliability of results. Additionally, we address the challenges associated with the application of these sensors in complex matrices, such as interferences from other components and the need for sample pretreatment. Finally, we present future perspectives for developing screen-printed electrochemical sensors, with an emphasis on new technologies and materials that can improve the sensitivity, selectivity, and stability of these devices.
Open AccessDevelopment of Novel Conductive Inks for Screen-Printed Electrochemical Sensors: Enhancing Rapid and Sensitive Drug Detection
The development of screen-printed electrochemical sensors represents a rapidly expanding research field with great potential for applications in the rapid and sensitive determination of drugs in complex matrices. This work presents a review of the state-of-the-art examples of this technology, focusing on its application in real matrices such as water, pharmaceutical formulations, and biological fluids. We discuss the main materials used in developing conductive inks, highlighting their properties and influence on sensor performance. The characterization of materials and sensors is crucial to ensure the reproducibility and reliability of results. Additionally, we address the challenges associated with the application of these sensors in complex matrices, such as interferences from other components and the need for sample pretreatment. Finally, we present future perspectives for developing screen-printed electrochemical sensors, with an emphasis on new technologies and materials that can improve the sensitivity, selectivity, and stability of these devices.
- Open Access
Electrochemical Determination of Catechol Using a Disposable Printed Electrode with Conductive Ink Based on Graphite and Carbon Black
Catechol (CT) is a phenolic compound widely used in various industrial sectors, but it is toxic; thus, there is a need for methods that aim to identify and quantify the existence of residues of this material in the environment. In this study a disposable printed electrochemical sensor was developed as an effective alternative for determining CT in water samples. The electrode, called SPEC, was manufactured using the screen-printing method using polyethylene terephthalate (PET) as a support, in which a conductive ink based on carbonaceous materials was used to print the working and auxiliary electrodes and a silver/silver chloride of ink on the reference electrode. The optimal ratio for the conductive ink was 6.25% carbon black, 35.42% graphite, and 58.33% nail polish. The ink obtained was characterized by scanning electron microscopy (SEM). The assessment of the effect of pH on the redox process showed Nernstian behavior (0.057 V pH−1), indicating that the process involves the same number of protons and electrons. Under optimized conditions, with 0.2 mol L−1 acetate buffer at pH 5.0, and by square wave voltammetry, the sensor presented sensitivity values of 0.31 μA L μmol−1, a detection limit of 5.96 μmol L−1, and a quantification limit of 19.87 μmol L−1. The sensor was applied to determine CT in tap water samples, and the results showed recoveries between 97.95 and 100.17%.
Open AccessElectrochemical Determination of Catechol Using a Disposable Printed Electrode with Conductive Ink Based on Graphite and Carbon Black
Catechol (CT) is a phenolic compound widely used in various industrial sectors, but it is toxic; thus, there is a need for methods that aim to identify and quantify the existence of residues of this material in the environment. In this study a disposable printed electrochemical sensor was developed as an effective alternative for determining CT in water samples. The electrode, called SPEC, was manufactured using the screen-printing method using polyethylene terephthalate (PET) as a support, in which a conductive ink based on carbonaceous materials was used to print the working and auxiliary electrodes and a silver/silver chloride of ink on the reference electrode. The optimal ratio for the conductive ink was 6.25% carbon black, 35.42% graphite, and 58.33% nail polish. The ink obtained was characterized by scanning electron microscopy (SEM). The assessment of the effect of pH on the redox process showed Nernstian behavior (0.057 V pH−1), indicating that the process involves the same number of protons and electrons. Under optimized conditions, with 0.2 mol L−1 acetate buffer at pH 5.0, and by square wave voltammetry, the sensor presented sensitivity values of 0.31 μA L μmol−1, a detection limit of 5.96 μmol L−1, and a quantification limit of 19.87 μmol L−1. The sensor was applied to determine CT in tap water samples, and the results showed recoveries between 97.95 and 100.17%.