RRRumen Radev

Rumen Radev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rumen Radev has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • IMPACT OF DATASET SIZE ON GANS USED FOR THE GENERATION OF PROSTHETIC CONSTRUCTIONS. A NARRATIVE REVIEW

    by Aleksandar Naydenov, Todor Uzunov, Elka Radeva, Georgi Kostadinov, Rumen Radev

    Purpose: To examine the reporting and influence of dataset quantity and quality in generative adversarial network (GAN)-based dental prosthetic generation and to summarize the evidence available through 16 July 2026. Material/Methods: A structured literature search was conducted in PubMed, Scopus, Web of Science, IEEE Xplore, SpringerLink, arXiv, and Google Scholar. Fifteen original GAN or explicitly adversarial studies of prosthetic generation or validation were included in the focused qualitative synthesis. Nine non-GAN generative or automated artificial-intelligence studies published in 2025-2026 were analyzed separately as contextual evidence. Results: Dataset definitions ranged from small three-dimensional collections to more than 1500 depth-map cases. ToothGAN used 814 natural-tooth and technician-designed cases and showed that the dataset composition affected anatomical features, groove depth, and occlusal contact characteristics. A 3D GAN implant-crown study demonstrated that overlap metrics should be interpreted together with clinically relevant emergence-profile parameters. Contextual transformer, point-cloud, diffusion, and commercial-system studies reported increasingly explicit data splits and clinical endpoints, although several proprietary systems did not disclose their training data. Conclusions: No universal minimum dataset size can be established. Dataset composition, anatomical diversity, ground-truth definition, resolution, augmentation, independent testing, and clinical validation are at least as important as sample count.

  • COLOR CHARACTERISTICS OF THE ANTERIOR TEETH IN DENTAL STUDENTS

    by Ilia Liondev, Ivet Dzhondrova, Rumen Radev, Dimitar Kirov, Elka Radeva, Rangel Todorov

    Introduction: Tooth color is a key determinant of dental aesthetics and critically influences patient satisfaction. Traditional shade matching is subjective and inconsistent, while spectrophotometry offers standardized, reproducible, and objective measurements. Defining the natural color profiles of anterior teeth in young adults is essential for predictable and high-quality esthetic restorations. The purpose of this study is to analyze the color characteristics of the maxillary central incisors, lateral incisors, and canines in a population of young adults aged 18–21 using a spectrophotometer (Spectroshade; MHT Optic Research). Materials and Methods: Color measurements were conducted on 153 dental students aged 18–21 years using the SpectroShade Micro spectrophotometer. The teeth examined were maxillary central (11, 21), lateral incisors (12, 22) and canines (13, 23). VITA Classical shades were matched and subsequently converted to CIELAB values (L*, a*, b*). Statistical analysis included mean, SD, and one-way ANOVA (α = 0.05). Results: The central incisors had the highest L* (lightness) values, indicating greater brightness. Canines presented significantly higher b* values, reflecting more pronounced yellowness. Statistically significant differences (p < 0.05) were observed among the tooth groups. Conclusion: Color parameters of anterior teeth vary significantly between tooth types in young adults. These findings are valuable for aesthetic restorative procedures and provide a reference for shade selection in this age group.


  • SHEAR BOND STRENGTH OF LITHIUM DISILICATE AND HYBRID CERAMIC WITH THREE TYPES OF LUTING CEMENT (A PILOT STUDY)

    by Mariana Yankova, Rumen Radev, Todor Uzunov, Nikolay Apostolov, Elka Radeva

    The present pilot study aimed to determine the bond strength between dentin and two types of ceramics cemented using three types of luting agents. The purpose of this pilot study was to determine the bond strength between dentin and two types of ceramics cemented using three types of luting agents. Materials and Methods: Seventy-two dentin discs were prepared from extracted teeth with intact dental crowns. Ceramic cylinders of two types, lithium disilicate (IPS emax CAD) and hybrid Ceramic (Vita Enamic), were cut and sintered to dimensions of 6/6 mm. Test specimens (dentin – cement – ceramic) were distributed into six groups (n = 12), depending on the ceramic material used and the cement used for adhesive fixation (eCEMENT, Variolink Esthetic DC, Panavia V5). They were subjected to shear bond strength testing. The results were statistically analyzed using IBM SPSS Statistics 26 with a significance level of 0.05. Results: In Vita Enamic, the highest shear bond strength was observed with Panavia V5 cement (18.87±0.89 MPa), followed by Variolink Esthetic DC (14.03±4.45 MPa) and e-CEMENT (11.40±5.19 MPa) (p < 0.05). In IPS emax CAD, the best bond was again with Panavia V5 cement (17.53±3.39 MPa), followed by Variolink Esthetic DC (17.30±4.49 MPa) and eCEMENT (14.33±5.27 MPa), however without statistical significance (p > 0.05). Conclusions: Within the limitation of the presented study, the composite cement Panavia V5 demonstrates better adhesive properties than the other two types of cement.

  • EFFECT OF DIFFERENT CLEANING PROTOCOLS ON THE HARDNESS OF FLEXIBLE DENTURE BASE MATERIAL "THERMOSENS”

    by Rumen Radev, Nikolay Apostolov, Elka Radeva

    Introduction. The growing use of flexible dentures in everyday dental practice calls for further studies on how various disinfection methods influence their mechanical properties, particularly their hardness. Purpose. The aim of the study was to evaluate how different cleaning techniques under varying conditions affect the hardness (HVN) of the "ThermoSens" denture base material. Materials and Methods. Forty flexible denture samples, measuring 10 mm in width and 3 mm in height, were made and grouped into ten sets (T1-T10) based on the disinfection method applied. For 30 days, all samples were submerged in artificial saliva and cleaned with common products (soap, toothpaste, Protefix, and Corega tablets). Each sample was then evaluated in five surface areas using the Vickers hardness test, with the data statistically analyzed using IBM SPSS Statistics 26, Excel 2015, and EdrawMax 7. Results. No statistically significant difference was found between the individual groups using different disinfection methods and protocols compared to the control group. Only in group 2, daily cleaning with Corega tablets (9.3 HVN) resulted in a statistically significant increase in hardness compared to the control group.When comparing experimental group 2 with the other groups, a statistically significant difference was found with all groups except group 3 (9.0 HVN) and group 4 (9.1 HVN). Groups 2, 3, and 4 exhibited the highest hardness. Conclusion. The use of different conventional cleaning methods does not alter the hardness of the flexible ThermoSens denture base material.


  • COLONIZATION OF CANDIDA SPP. IN PATIENTS TREATED WITH PARTIAL DENTURES "THERMOSENS"

    by Rumen Radev, Mariana Yankova, Elka Radeva, Nikolay Apostolov

    Introduction. One of the commonly encountered pathologies in the oral cavity when using removable dentures is denture stomatitis, attributed to Candida spp. colonization on the denture surface. Aim. Determination of the type and quantity of Candida spp. on the mucosal and denture surfaces in patients treated with "ThermoSens" partial dentures before and after treatment. Materials and Methods. Thirty patients were prosthetically treated and divided into 2 groups. In the first group (n=20), treatment was performed with "ThermoSens" partial dentures, while in the second (control) group, patients were treated with conventional dentures (n=10). Swabs were taken from the mucosal and denture surfaces. The samples were tested for quantitative and qualitative differentiation of Candida spp. before prosthetic treatment, at the first and third month after prosthetic treatment. The data was statistically processed using SPSS Statistics 26. Results. No statistically significant difference was observed regarding the quantitative accumulation of Candida spp. on the denture and mucosal surfaces between the two groups of patients (p>5%), measured at 1 month and 3 months after prosthetic treatment. It was found that the predominant Candida spp. in both groups of patients was Candida albicans. Conclusion. Although no statistically significant difference was observed in the two test groups regarding the number of colonies of Candida spp., the main group showed a tendency for a more significant increase in their number (up to 105 CFU/ml) on the denture surfaces at the third month after prosthetic treatment, which may be a presumption for the development of denture stomatitis.


  • Open Access

    Clinical Approach in Prosthetic Treatment With 3D‐Printed Implant‐Retained Removable Denture: DENTCA System

    by Aleksandar Naydenov, Nikolay Apostolov, Rumen Radev

    The aim of this study is to present a method that optimizes clinical and laboratory workflow in the fabrication of implant‐supported removable dentures by combining conventional and digital protocols. A 73‐year‐old patient came to our clinic for treatment of a completely edentulous lower jaw. Two Neodent Helix GM implants were placed in the canine regions and a removable denture with Locator GM Novaloc retention elements was fabricated. The DENTCA system was used for impressions, border molding, and to determine both occlusovertical dimension (OVD) and reproducible, physiological position of lower jaw (RPPLJ) in a single clinical visit. In result, we have fabricated a removable denture with implant retention in just two appointments. We can conclude that DENTCA system is a reliable method that allows fabrication of implant‐retained removable denture in two clinical visits. The registration of the prosthetic field boundaries, OVD and RPPLJ, combined with CAD technologies, represents a contemporary and accurate method. It takes less time, and expenses are reduced both for the dentist and the patient.