Junyi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Junyi Zhao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Shasha Yang
Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing 210096, China
1 shared publication - Shiwen Gao
Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing 210096, China
1 shared publication - Wence Hu
The Key Laboratory of MEMS, Ministry of Education, Southeast University, Nanjing 210096, China
1 shared publication - Yi Zhuang
Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing 210096, China
1 shared publication - Zhenxiang Yi
Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing 210096, China
1 shared publication
Latest Publications
- Open Access
- 5 June 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 758
Non-Destructive Sensor for Glucose Solution Concentration Detection Using Electromagnetic Technology
In this paper, a sensor using a complementary split ring resonator (CSRR) is proposed for non-destructive testing of blood glucose. By depicting the complementary split ring structure on the ground, the electromagnetic field strength between the split rings can be enhanced effectively. The structure size of the sensor by CSRR is determined by simulation, so that the insertion loss curve of the device has a resonance point at the frequency of 3.419 GHz. With a special holder created by three-dimensional (3D) printing technology, the test platform was established when the concentration of the solution varied from 0 mg/mL to 20 mg/mL. The experimental results indicate that there is an obvious linear relationship between the insertion loss S21 and the glucose concentration at the resonant frequency. Similarly, the measured real part and imaginary part of the S21 both vary with glucose concentration linearly. Based on the above experimental results, the feasibility of the sensor using a CSRR proposed in this paper for non-destructive detection of blood glucose is preliminarily verified.
- 5 June 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (6) , 758
Open AccessNon-Destructive Sensor for Glucose Solution Concentration Detection Using Electromagnetic Technology
In this paper, a sensor using a complementary split ring resonator (CSRR) is proposed for non-destructive testing of blood glucose. By depicting the complementary split ring structure on the ground, the electromagnetic field strength between the split rings can be enhanced effectively. The structure size of the sensor by CSRR is determined by simulation, so that the insertion loss curve of the device has a resonance point at the frequency of 3.419 GHz. With a special holder created by three-dimensional (3D) printing technology, the test platform was established when the concentration of the solution varied from 0 mg/mL to 20 mg/mL. The experimental results indicate that there is an obvious linear relationship between the insertion loss S21 and the glucose concentration at the resonant frequency. Similarly, the measured real part and imaginary part of the S21 both vary with glucose concentration linearly. Based on the above experimental results, the feasibility of the sensor using a CSRR proposed in this paper for non-destructive detection of blood glucose is preliminarily verified.