SYShasha Yang

Shasha Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shasha Yang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Compact Wideband Vivaldi Antenna for Non-Invasive Glucose Monitoring

    by Shasha Yang, Yu Wang, Shiwen Gao, Yi Zhuang, Lifeng Wang, Zhenxiang Yi, Weixun Zhang

    Due to the high gain, wide bandwidth, and directional radiation characteristics of Vivaldi antennas, this paper conducted relevant research on the feasibility of non-destructive blood glucose detection based on Vivaldi antennas. The research included finite element method (FEM) simulation and glucose concentration monitoring. In the simulation stage, the power transmission and reflection characteristics, radiation characteristics, and electric field distribution characteristics of the antenna were described in detail. In the test stage, the S11 response of the antenna to variation in glucose concentration in the range of 0–6.11 mg/mL was measured, including the S11 amplitude and phase. The experimental results show that there is a high linear correlation between the S11 response and glucose concentration, and the sensitivity of the S11 amplitude response to the variation in glucose concentration is close to 0.3445 (dB/(mg/mL)) at 14.2556 GHz, and the sensitivity of the S11 phase response to the variation in glucose concentration is about 0.5652 (degree/(mg/mL)) at 14.37 GHz. In addition, the predicted results of the glucose concentration based on linear regression are discussed.


  • Open Access

    Non-Destructive Sensor for Glucose Solution Concentration Detection Using Electromagnetic Technology

    by Shasha Yang, Shiwen Gao, Yi Zhuang, Wence Hu, Junyi Zhao, Zhenxiang Yi

    In this paper, a sensor using a complementary split ring resonator (CSRR) is proposed for non-destructive testing of blood glucose. By depicting the complementary split ring structure on the ground, the electromagnetic field strength between the split rings can be enhanced effectively. The structure size of the sensor by CSRR is determined by simulation, so that the insertion loss curve of the device has a resonance point at the frequency of 3.419 GHz. With a special holder created by three-dimensional (3D) printing technology, the test platform was established when the concentration of the solution varied from 0 mg/mL to 20 mg/mL. The experimental results indicate that there is an obvious linear relationship between the insertion loss S21 and the glucose concentration at the resonant frequency. Similarly, the measured real part and imaginary part of the S21 both vary with glucose concentration linearly. Based on the above experimental results, the feasibility of the sensor using a CSRR proposed in this paper for non-destructive detection of blood glucose is preliminarily verified.