HTHuda Ismail Tulbah

Huda Ismail Tulbah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huda Ismail Tulbah has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical Evaluation of Short Tuberosity Implants among Type 2 Diabetic and Non-Diabetic Patients: A 5 Year Follow-Up

    by Huda I. Tulbah, Abdulaziz Alsahhaf, Hamad S. AlRumaih, Fahim Vohra, Tariq Abduljabbar

    Aim: To assess clinical and radiographic parameters including bleeding on probing (BoP); probing depth (PD), plaque index (PI) and crestal bone loss (CBL) around short tuberosity implants (STI) supporting fixed partial dentures in patients with Type 2 diabetes mellitus (T2DM) and non-diabetics. Material and Methods: Participants with T2DM and without T2DM with at least one STI (6 mm) posteriorly restored with a fixed partial denture splinting premolar implant were included. A questionnaire collected demographic details including gender, age, duration of diabetes, habits of brushing, the total number of dental implants and location, implant loading after placement, restoration type, and family history of DM. Clinical and radiographic assessment of peri-implant parameters, i.e., bleeding on probing (BoP), probing depth (PD), plaque index (PI), and crestal bone loss (CBL) was performed. The restorative success of STI was determined by no sensation of the foreign body, lack of pain and dysesthesia, lack of infection, no radiolucency around the implant, and no mobility. The Kruskal–Wallis test was used for statistical analysis. A p-value of less than 0.05 was considered statistically significant. Results: Twenty-five T2DM (19 males and 6 females) and 25 non-diabetic (18 males and 7 females) participants were included. The number of STIs in T2DM was 41, whereas in non-diabetic it was 38. At 1 year follow-up, mean PI% in T2DM participants was 18.9% (19.2–21.4%) and in non-diabetics it was 17.6% (16.3–18.5%). The mean PD was recorded in diabetics (1.3 ± 5.0 mm) and non-diabetics (1.1 ± 3.2 mm). The BoP value in diabetics was 44.9% (39.8–46.4%) and 28.2% in non-diabetics (17.2–24.6%). At 5 years of follow-up, the mean PI% range in T2DM participants was 26.18% (25.4–29.1%) and 24.42% in non-diabetic (20.1–25.5%). The mean PD in millimeters around STI in T2DM was observed to be 2.3 ± 4.8 mm and 1.4 ± 3.4 mm in non-diabetics. In addition, BoP in diabetic participants was 39.54% (27.7–42.1%) and 24.42% in non-diabetics (20.1–25.5%). A total of six STIs failed, i.e., two in the non-diabetic and four in the T2DM group. Conclusions: Patients with T2DM have poor periodontal (BoP, PD, CBL) and restorative peri-implant parameters around STIs when compared to healthy (non-diabetic) participants at five years of follow-up. For long-term stability, glycemic control is pivotal along with following good plaque control.


  • Retracted

    RETRACTED: Adhesive bond integrity of silanized zirconia nanoparticles in polymeric resin dentin bonding agent. An FTIR, SEM, and micro-tensile experiment

    by Basil Almutairi, Mashael Binhasan, Sara Shabib, Amal S. Al-Qahtani, Huda I. Tulbah, Khulud A. Al-Aali, Fahim Vohra, Tariq Abduljabbar


  • Open Access

    Influence of Concentration Levels of β-Tricalcium Phosphate on the Physical Properties of a Dental Adhesive

    by Amal S. Al-Qahtani, Huda I. Tulbah, Mashael Binhasan, Sara Shabib, Khulud A. Al-Aali, Mai M. Alhamdan, Tariq Abduljabbar

    Our study assessed the influence of integrating 5% and 10% tricalcium phosphate (β-TCP-Ca3(PO4)2.) nanoparticles into a dental adhesive on the adhesive’s bonding. To evaluate the filler nanoparticles, scanning electron microscopy (SEM), Energy Dispersive X-Ray (EDX) spectroscopy, Fourier-transform infrared (FTIR) spectroscopy, and micro-Raman spectroscopy techniques were used. Shear Bond strength (SBS) testing, degree of conversion (DC) analysis, investigation of the adhesive–dentin interface, and biofilm experiments were conducted. The SEM micrographs revealed non-uniform agglomerates, while the EDX demonstrated the existence of oxygen ‘O’ (24.2%), phosphorus ‘P’ (17.4%) and calcium ‘Ca’ (60.1%) in the β-TCP nanoparticles. The FTIR and micro-Raman spectra indicated characteristic bands for β-TCP containing materials. The 10 wt.% β-TCP adhesive presented the highest SBS values (NTC-10 wt.% β-TCP: 33.55 ± 3.73 MPa, TC-10 wt.% β-TCP: 30.50 ± 3.25 MPa), followed by the 5 wt.% β-TCP adhesive (NTC-5 wt.% β-TCP: 32.37 ± 3.10 MPa, TC-5 wt.% β-TCP: 27.75 ± 3.15 MPa). Most of the detected failures after bond strength testing were adhesive in nature. The β-TCP adhesives demonstrated suitable dentin interaction by forming a hybrid layer (with few or no gaps) and resin tags. The β-TCP adhesives (10 wt.%) revealed lower DC values compared to control. The incorporation of 5 and 10 wt.% concentrations of β-TCP particles resulted in an increase in SBS values. A linear decline in DC values was witnessed when the nanoparticle concentration was increased. Further research focusing on exploring the influence of higher filler concentrations on adhesive’s properties is recommended.


  • Open Access

    Polymer-Based Bioactive Luting Agents for Cementation of All-Ceramic Crowns: An SEM, EDX, Microleakage, Fracture Strength, and Color Stability Study

    by Samer Al-Saleh, Turki W. Aboghosh, Mousa S. Hazazi, Khalid A. Binsaeed, Abdulaziz M. Almuhaisen, Huda I. Tulbah, Amal S. Al-Qahtani, Sara Shabib, Mashael Binhasan, Fahim Vohra, et al.

    The aim of the study was to compare microleakage and fracture loads of all ceramic crowns luted with conventional polymer resins and polymeric bioactive cements and to assess the color stability of polymeric bioactive cements. Seventy-five extracted premolar teeth were tested for fracture loads and microleakage in all-ceramic crowns cemented with two types of polymeric bioactive cements and resin cements. In addition, the degree of color change for each cement with coffee was assessed. Thirty maxillary premolar teeth for fracture loads and thirty mandibular premolar teeth for microleakage were prepared; standardized teeth preparations were performed by a single experienced operator. All prepared specimens were randomly distributed to three groups (n = 20) based on the type of cement, Group 1: resin cement (Multilink N); Group 2: polymeric bioactive cement (ACTIVA); Group 3: polymeric bioactive cement (Ceramir). The cementation procedures for all cements (Multilink, ACTIVA, and Ceramir) were performed according to the manufacturers’ instructions. All specimens were aged using thermocycling for 30,000 cycles (5–55 °C, dwell time 30 s). These specimens were tested using the universal testing machine for fracture strength and with a micro-CT for microleakage. For the color stability evaluation, the cement specimens were immersed in coffee and evaluated with a spectrometer. Results: The highest and lowest means for fracture loads were observed in resin cements (49.5 ± 8.85) and Ceramir (39.8 ± 9.16), respectively. Ceramir (2.563 ± 0.71) showed the highest microleakage compared to resin (0.70 ± 0.75) and ACTIVA (0.61 ± 0.56). ACTIVA cements showed comparable fracture loads, microleakage, and stain resistance compared to resin cements.


  • Effectiveness of synthetic and natural photosensitizers and different chemical disinfectants on the contaminated metal crown

    by Samar Al-Saleh, Ahmed Heji Albaqawi, Feras Alrawi, Huda I. Tulbah, Amal S Al-Qahtani, Emal Heer, Sidra Sadaf Nisar, Fahim Vohra, Tariq Abduljabbar


  • Open Access

    Surface Properties of Polymer Resins Fabricated with Subtractive and Additive Manufacturing Techniques

    by Amal S. Al-Qahtani, Huda I. Tulbah, Mashael Binhasan, Maria S. Abbasi, Naseer Ahmed, Sara Shabib, Imran Farooq, Nada Aldahian, Sidra S. Nisar, Syeda A. Tanveer, et al.

    This study aimed to compare the surface roughness, hardness, and flexure strength of interim indirect resin restorations fabricated with CAD-CAM (CC), 3D printing (3D), and conventional techniques (CV). Twenty disk (3 mm × Ø10 mm) and ten bar specimens (25 × 2 × 2 mm) were fabricated for the CC, 3D, and CV groups, to be used for surface roughness, micro-hardness, and flexural strength testing using standardized protocol. Three indentations for Vickers micro-hardness (VHN) were performed on each disk and an average was identified for each specimen. Surface micro-roughness (Ra) was calculated in micrometers (μm) using a 3D optical non-contact surface microscope. A three-point bending test with a universal testing machine was utilized for assessing flexural strength. The load was applied at a crosshead speed of 3 mm/min over a distance of 25 mm until fracture. Means and standard deviations were compared using ANOVA and post hoc Tukey–Kramer tests, and a p-value of ≤0.05 was considered statistically significant. Ra was significantly different among the study groups (p < 0.05). Surface roughness among the CC and CV groups was statistically comparable (p > 0.05). However, 3D showed significantly higher Ra compared to CC and CV samples (p < 0.05). Micro-hardness was significantly higher in 3D samples (p < 0.05) compared to CC and CV specimens. In addition, CC and CV showed comparable micro-hardness (p > 0.05). A significant difference in flexural strength was observed among the study groups (p < 0.05). CC and 3D showed comparable strength outcomes (p > 0.05), although CV specimens showed significantly lower (p < 0.05) strength compared to CC and 3D samples. The 3D-printed provisional restorative resins showed flexural strength and micro-hardness comparable to CAD-CAM fabricated specimens, and surface micro-roughness for printed specimens was considerably higher compared to CAD-CAM and conventional fabrication techniques.


  • Open Access

    Influence of TiO2 and ZrO2 Nanoparticles on Adhesive Bond Strength and Viscosity of Dentin Polymer: A Physical and Chemical Evaluation

    by Samar Al-Saleh, Abdullah Alateeq, Abdulaziz H. Alshaya, Amal S. Al-Qahtani, Huda I. Tulbah, Mashael Binhasan, Sara Shabib, Imran Farooq, Fahim Vohra, Tariq Abduljabbar

    The present study aimed to formulate an experimental adhesive (EA) and reinforce it with 5 wt.% titanium dioxide (TiO2) or zirconium oxide (ZrO2) to yield 5% TiO2 and 5% ZrO2 adhesives, respectively, and then analyze the impact of this reinforcement on various mechanical properties of the adhesives. The EA contained a blend of monomers such as bisphenol A glycol dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA), 2-hydroxyethyl methacrylate (HEMA), and ethyl 4-dimethylamino benzoate and camphorquinone. The EA included ethyl 4-dimethylamino benzoate and camphorquinone photo-initiators, and diphenyliodonium hexafluorophosphate (DPIHP) was also included to act as an electron initiator. The TiO2 and ZrO2 nanoparticles were incorporated into the EA post-synthesis. To characterize the filler nanoparticles, scanning electron microscopy (SEM) and line-energy dispersive X-ray (EDX) spectroscopy were performed. The adhesives were characterized by analyzing their rheological properties, shear-bond strength (SBS), and interfacial failure types. Further, the resin–dentin interface was also analyzed via SEM. The TiO2 nanoparticles were spherically shaped on the SEM micrographs, while the ZrO2 nanoparticles were seen as non-uniformly shaped agglomerates. The EDX mapping demonstrated the presence of Ti and oxygen for TiO2 and Zr and oxygen for the ZrO2 nanoparticles. Both 5% TiO2 and 5% ZrO2 adhesives revealed decreased viscosity as compared with the EA. The 5% TiO2 adhesive demonstrated higher SBS values for both non-thermocycled (NTC) and thermocycled samples (NTC: 25.35 ± 1.53, TC: 23.89 ± 1.95 MPa), followed by the 5% ZrO2 adhesive group (NTC: 23.10 ± 2.22, TC: 20.72 ± 1.32 MPa). The bulk of the failures (>70%) were of adhesive type in all groups. The SEM analysis of the resin–dentin interface revealed the development of a hybrid layer and resin tags (of variable depth) for the EA and 5% TiO2 groups. However, for the 5% ZrO2 group, the hybrid layer and resin tag establishment appeared compromised. Reinforcement of the EA with TiO2 or ZrO2 caused an increase in the adhesive’s SBS (with the 5% TiO2 group demonstrating the highest values) in comparison with the EA (without nanoparticles). However, both nanoparticle-containing adhesives revealed decreased viscosity compared with the EA (without nanoparticles). Further studies investigating the impact of diverse filler concentrations on the properties of adhesives are suggested.


  • A comparative evaluation of the effect of phototherapy of fiber post on its bond strength to dental composite

    by Amal Saeed Al-Qahtani, Sahar Asaad AlZain, Eman Mohammed AlHamdan, Huda Ismail Tulbah, Hana Mohammed Al Alsheikh, Mustafa Naseem, Fahim Vohra