MDMusa Dahu

Musa Dahu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Musa Dahu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Duane C. Berkompas

    Division of Neurology (MK, MM, PM, NW, NIK, AA, EE, JM), Neuroscience Institute, Spectrum Health, Grand Rapids; Michigan State University (MK, MM, PM, JPT, WM, DB, NW, NIK, AA, MD, AG, NC, JM), Grand Rapids; Department of Neurology (MK), Mayo Clinic, Rochester, MN; Division of Neurosurgery (JPT), Neuroscience Institute, Grand Rapids; and Division of Cardiology (WM, DB, MD, AG, TM, NC), Heart and Vascular Institute, Spectrum Health, Grand Rapids, MI

    2 shared publications
  • Jiangyong Min

    Department of Neurosciences, Corewell Health West and Michigan State University, Grand Rapids (J. Min, N.H.A.).

    2 shared publications
  • Muhib Khan

    Department of Neurology, Mayo Clinic; Rochester, MN, United States

    2 shared publications
  • Alfred Albano

    Department of Cardiovascular Medicine, Frederik Meijer Heart and Vascular Institute, Corewell Health West Grand Rapids Michigan USA

    1 shared publication
  • Andre Gauri

    Department of Cardiovascular Medicine, Frederik Meijer Heart and Vascular Institute, Corewell Health West Grand Rapids Michigan USA

    1 shared publication
  • Andre Gauri

    Division of Neurology (MK, MM, PM, NW, NIK, AA, EE, JM), Neuroscience Institute, Spectrum Health, Grand Rapids; Michigan State University (MK, MM, PM, JPT, WM, DB, NW, NIK, AA, MD, AG, NC, JM), Grand Rapids; Department of Neurology (MK), Mayo Clinic, Rochester, MN; Division of Neurosurgery (JPT), Neuroscience Institute, Grand Rapids; and Division of Cardiology (WM, DB, MD, AG, TM, NC), Heart and Vascular Institute, Spectrum Health, Grand Rapids, MI

    1 shared publication

Latest Publications

  • Open Access

    Conduction System Pacing With DF‐1 ICD Systems Using a Medtronic 3830 Lead: A Feasibility Study

    by Melanie Mrozek, Navjot Azad, Robert Ocomen, Mohamed El Shami, Maria Kim, Megan Rose, Jack Tietema, Ibrahim Khaleel, Alfred Albano, Jayson Baman, et al.

    Background: Patients with implantable cardioverter‐defibrillators (ICDs) who require ventricular pacing are at risk for pacing‐induced cardiomyopathy (PICM) from chronic right ventricular (RV) pacing. Conduction system pacing (CSP), particularly left bundle branch area pacing (LBBAP), offers more physiologic ventricular activation, but integration with ICD therapy remains challenging. The DF‐1 ICD connector standard provides an opportunity to incorporate a separate CSP lead while maintaining high‐voltage ICD therapy. We evaluated the feasibility of an alternative ICD configuration using a DF‐1 defibrillation lead paired with a Medtronic 3830 CSP lead connected to a dual‐chamber ICD generator. Methods: We conducted a retrospective case series of 17 consecutive patients who underwent this configuration at a single center between October 2022 and August 2025. For subgroup analyses, patients were stratified by baseline left ventricular ejection fraction (LVEF) as LVEF ≤ 50% ( n = 9) or LVEF > 50% ( n = 8). QRS duration, LVEF, left ventricular end‐systolic dimension (LVESD), tricuspid regurgitation (TR) severity, and device outcomes were assessed during follow‐up. Results: Median follow‐up was 15.0 months (IQR 6.2–19.2). The Medtronic 3830 lead was successfully implanted in all 17 patients, with confirmed LBBAP in 16 patients (94.1%) and deep septal pacing without definitive left bundle branch capture in one patient. No CSP lead revisions for mechanical or electrical failure were required. Among patients with paired measurements, LVEF increased from 41.6% ± 15.0% to 45.9% ± 14.1%, although the change was not statistically significant ( p = 0.169), while LVESD decreased from 4.33 ± 0.72 cm to 3.89 ± 0.79 cm ( p = 0.022). In paired subgroup analyses, patients with baseline LVEF ≤50% demonstrated an increase in LVEF from 31.9% ± 6.2% to 40.1% ± 14.3% ( p = 0.053) and a decrease in LVESD from 4.62 ± 0.65 cm to 4.11 ± 0.71 cm ( p = 0.048), whereas patients with baseline LVEF >50% demonstrated no significant change in either measure. QRS duration did not change significantly in either subgroup. Overall TR severity did not change significantly (Bhapkar p = 0.337), although 5 of 12 patients with paired imaging experienced at least a one‐grade increase in TR severity and no patient developed new severe TR. Two patients (11.8%) died during follow‐up, with neither death attributed to the device configuration. Conclusion: An ICD configuration using a DF‐1 defibrillation lead paired with a Medtronic 3830 CSP lead on a dual‐chamber generator was technically feasible, with successful 3830 lead implantation in all patients, confirmed LBBAP in 94.1%, and no CSP lead revisions for mechanical or electrical failure during intermediate‐term follow‐up. Patients with baseline LVEF ≤50% demonstrated numerical improvement in LVEF and a reduction in LVESD, while ventricular function remained stable in those with LVEF >50%. These exploratory findings require confirmation in larger prospective comparative studies.

  • Multidisciplinary Approach to Patent Foramen Ovale Closure for Cryptogenic Stroke

    by Muhib Khan, Malgorzata Miller, Philip Mccarthy, Jenny P. Tsai, William Merhi, Duane Berkompas, Nabil Wees, Nadeem I. Khan, Asad Ahrar, Elizabeth Evans, et al.

    Patent foramen ovale (PFO) is present in approximately 25% of adult population. The prevalence of PFO is high in patients with cryptogenic stroke suggesting paradoxical embolism. PFO closure in carefully selected patients is an effective secondary preventive strategy in these patients. We report predictors of management recommendations by the multidisciplinary Board and their impact on outcomes. Brain-Heart Board comprises vascular and interventional neurology and cardiology subspecialties (structural, electrophysiology, and cardiac imaging). Adult patients referred to the Board for consideration of PFO closure between October 2017 to March 2021 were included in this retrospective cohort analysis. Demographics, comorbid conditions, risk of paradoxical embolism (RoPE) score, event frequencies (transient ischemic attack [TIA] or stroke, intracranial hemorrhage [ICH], post-PFO closure cardiac arrhythmias), and modified Rankin Scale (mRS) at 1 year were compared between the groups (PFO closure vs medical management). Multivariable logistic regression was used to identify factors associated with management recommendation and chi-square tests to test differences in outcomes for patients according to management. Two hundred seventy patients (229 stroke; 41 TIA) were discussed by the Board for PFO closure. 119 (44.0%) patients were recommended for PFO closure of which 117 (98.3%) had evidence of ischemic infarct on imaging. In univariate analysis, age was similar (50 ± 11.9 vs 52 ± 12.8, p = 0.17), but RoPE score was higher in closure as compared with the medical management group (6 [IQR 5-7] vs 5 [IQR 4-7], p < 0.05). In multivariable analysis, TIA as the index event was an independent predictor of Board recommendation against PFO closure (OR 0.05, 95% CI 0.01-0.19, p < 0.05). Event frequency was low in both cohorts (5.9% vs 4.8%, p > 0.05) and comprised cardiac arrhythmias (6 cases of atrial fibrillation and 1 ICH in closure group; 1 TIA and 1 recurrent stroke in medical management group). Excellent functional outcome (mRS 0-1) was similar in both cohorts (66.3% vs 70.7%, p > 0.05) at 1 year. Multidisciplinary Brain-Heart Board provides a clinical practice model of collaborative care to ensure proper patient selection for PFO closure. TIA as the index event is associated with recommendation of medical management by the multidisciplinary Brain-Heart Board.


  • Left Atrial Appendage Occlusion as Escalation of Therapy for Secondary Prevention of Ischemic Stroke

    by Stephen E. Wilkinson, Marvin L. Kajy, Duane C. Berkompas, Musa I. Dahu, Jiangyong John Min, Muhib Khan