Zongjin Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zongjin Ren has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Jun Zhang
School of Mechanical Engineering, Dalian University of Technology, Dalian, China
5 shared publications- Jun Zhang
Dalian University of Technology
5 shared publications - Wei Liu
Dalian University of Technology
5 shared publications Zhenyuan Jia
School of Mechanical Engineering, Dalian University of Technology, Dalian, China
5 shared publications- Jin Wang
Dalian University of Technology
4 shared publications - Xinyang Li
School of Mechanical Engineering, Dalian University of Technology (DUT), Dalian, China
3 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (5) , 5854-5863
Optimization and Performance Improvement of Multisensor Piezoelectric Balance Assembly Method Based on a Complex Super-Statical Determinate Structure
Multisensor piezoelectric balances are increasingly used in wind tunnel tests requiring high dynamic performance, due to their flexible structure, easy fabrication, high stiffness, and excellent dynamic performance. However, superimposed manufacturing and assembly errors degrade their force-measuring performance. To address this issue, this article proposes a novel assembly method for such balances based on a complex statically indeterminate structure. The method controls the preload of connecting bolts using a digital torque wrench and optimizes sensor height via three approaches, leveraging coordinate measuring machine data and copper sheets’ high plasticity. Mechanical and mathematical models were established, followed by simulations to analyze error impacts, and a six-component force calibration system was built for static/dynamic tests. Results show that placing copper sheets on sensors’ top/bottom (with uniform bolt preload) significantly reduces force imbalance; top-placed sheets improve static performance. Natural frequency tests confirm no negative impact on dynamic performance, verifying the method’s effectiveness and feasibility.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (5) , 5854-5863
Optimization and Performance Improvement of Multisensor Piezoelectric Balance Assembly Method Based on a Complex Super-Statical Determinate Structure
Multisensor piezoelectric balances are increasingly used in wind tunnel tests requiring high dynamic performance, due to their flexible structure, easy fabrication, high stiffness, and excellent dynamic performance. However, superimposed manufacturing and assembly errors degrade their force-measuring performance. To address this issue, this article proposes a novel assembly method for such balances based on a complex statically indeterminate structure. The method controls the preload of connecting bolts using a digital torque wrench and optimizes sensor height via three approaches, leveraging coordinate measuring machine data and copper sheets’ high plasticity. Mechanical and mathematical models were established, followed by simulations to analyze error impacts, and a six-component force calibration system was built for static/dynamic tests. Results show that placing copper sheets on sensors’ top/bottom (with uniform bolt preload) significantly reduces force imbalance; top-placed sheets improve static performance. Natural frequency tests confirm no negative impact on dynamic performance, verifying the method’s effectiveness and feasibility.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 11679-11687
Design and Performance Research of a Spindle-Integrated Rotational Piezoelectric Testing System for Upset Force Measurement During Welding Processes
Accurate monitoring of high-frequency upset force during friction stir welding (FSW) is a critical step for optimizing welding process parameters and ensuring joint quality. However, traditional platform-type force gauges cannot measure the upset force in the bobbin tool friction stir welding (BT-FSW) process, which poses a technical challenge. To resolve this issue, a high-frequency spindle-integrated rotational piezoelectric testing system (SIR-PTS) mounted on the equipment spindle was designed. This system uses piezoelectric sensors as measuring elements and comprises a force gauge, a built-in signal conditioning circuit, and monitoring software. First, a theoretical mechanical model under rotational conditions was established to determine the dimensional parameters of the piezoelectric quartz wafers. Subsequently, ANSYS finite element simulation was utilized to analyze the static structural characteristics and dynamic response of the testing system. Meanwhile, a modular hardware circuit integrating charge conversion, filtering, and wireless transmission functions was developed. A series of verification experiments were conducted to evaluate the system performance. The experimental results demonstrate that the system exhibits a static linearity error of 0.64% and a repeatability error of 0.34%. Its main-direction natural frequency is 2082.52 Hz, which meets the requirements of high-frequency dynamic testing. These results confirm that the system can realize high-precision, real-time dynamic monitoring of upset force in BT-FSW processes.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 11679-11687
Design and Performance Research of a Spindle-Integrated Rotational Piezoelectric Testing System for Upset Force Measurement During Welding Processes
Accurate monitoring of high-frequency upset force during friction stir welding (FSW) is a critical step for optimizing welding process parameters and ensuring joint quality. However, traditional platform-type force gauges cannot measure the upset force in the bobbin tool friction stir welding (BT-FSW) process, which poses a technical challenge. To resolve this issue, a high-frequency spindle-integrated rotational piezoelectric testing system (SIR-PTS) mounted on the equipment spindle was designed. This system uses piezoelectric sensors as measuring elements and comprises a force gauge, a built-in signal conditioning circuit, and monitoring software. First, a theoretical mechanical model under rotational conditions was established to determine the dimensional parameters of the piezoelectric quartz wafers. Subsequently, ANSYS finite element simulation was utilized to analyze the static structural characteristics and dynamic response of the testing system. Meanwhile, a modular hardware circuit integrating charge conversion, filtering, and wireless transmission functions was developed. A series of verification experiments were conducted to evaluate the system performance. The experimental results demonstrate that the system exhibits a static linearity error of 0.64% and a repeatability error of 0.34%. Its main-direction natural frequency is 2082.52 Hz, which meets the requirements of high-frequency dynamic testing. These results confirm that the system can realize high-precision, real-time dynamic monitoring of upset force in BT-FSW processes.
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (1) , 896-905
Design and Calibration of a Large-Sized and High-Stiffness Wind Tunnel Test Dynamometer Composed of Dual Multipoint Distributed Force-Measuring Units
Wind tunnel tests are crucial for evaluating aerospace vehicle performance during development. However, existing force measurement systems struggle with large-scale, high-load test models. This study proposes a large, high-stiffness wind tunnel dynamometer using dual multipoint distributed force-measurement units. A mechanical model based on point-support theory was established to derive input-output force/torque relationships, enabling calculation of structural dimensions and sensor ranges. A 3-D simulation model validated the system’s structural strength through static analysis. Independent calibration of each unit ensured reliable force measurement, reducing errors. A custom six-dimensional calibration device was designed, verified via finite element analysis, and used for unidirectional force calibration and dynamic testing. The dynamometer achieved static performance meeting design specifications (linearity error ≤0.3% for forces, ≤0.6% for torques; repeatability error ≤1% ), with a maximum linearity error of 0.335% . Decoupling compensation further enhanced six-dimensional force/torque measurement accuracies to 0.086% –1.627%, demonstrating up to 92.65% improvement. Experiments confirmed the model’s theoretical validity, simulation accuracy, and applicability to large-scale, high-load, and high-frequency scenarios. This solution addresses critical gaps in modern wind tunnel testing for large aircraft models.
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (1) , 896-905
Design and Calibration of a Large-Sized and High-Stiffness Wind Tunnel Test Dynamometer Composed of Dual Multipoint Distributed Force-Measuring Units
Wind tunnel tests are crucial for evaluating aerospace vehicle performance during development. However, existing force measurement systems struggle with large-scale, high-load test models. This study proposes a large, high-stiffness wind tunnel dynamometer using dual multipoint distributed force-measurement units. A mechanical model based on point-support theory was established to derive input-output force/torque relationships, enabling calculation of structural dimensions and sensor ranges. A 3-D simulation model validated the system’s structural strength through static analysis. Independent calibration of each unit ensured reliable force measurement, reducing errors. A custom six-dimensional calibration device was designed, verified via finite element analysis, and used for unidirectional force calibration and dynamic testing. The dynamometer achieved static performance meeting design specifications (linearity error ≤0.3% for forces, ≤0.6% for torques; repeatability error ≤1% ), with a maximum linearity error of 0.335% . Decoupling compensation further enhanced six-dimensional force/torque measurement accuracies to 0.086% –1.627%, demonstrating up to 92.65% improvement. Experiments confirmed the model’s theoretical validity, simulation accuracy, and applicability to large-scale, high-load, and high-frequency scenarios. This solution addresses critical gaps in modern wind tunnel testing for large aircraft models.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error
The rotor system is a crucial component in the design and manufacture of helicopters. The accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this article presents a rotor balance based on the piezoelectric measurement principle for precise the measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Second, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error
The rotor system is a crucial component in the design and manufacture of helicopters. The accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this article presents a rotor balance based on the piezoelectric measurement principle for precise the measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Second, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.
- 20 November 2022
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 46 (1) , 53-62
Development of the piezoelectric dynamometer for brittle material drilling
When processing deep and small holes in optical glass with a diamond core drill, the cutting force is minimal and very variable. It is challenging to measure the cutting force because of the high cutting frequency and small value of the cutting operation. In this study, a piezoelectric three-component dynamometer with excellent axial sensitivity is developed based on the measuring properties of quartz wafers and characteristics of cutting forces during processing. The dynamometer’s four sensors are positioned vertically, which could increase the dynamometer’s axial sensitivity. The dynamometer’s calibration studies were conducted in both static and dynamic modes. The output consists of the dynamometer was verified using a multi-point loading experiment. According to the experimental findings, the dynamometer’s linearity error and repeatability error are both less than 0.5%. Less than 1.6% and 2.9%, respectively, are found in the output error and crosstalk of multi-point loading experiment. The frequency of nature is higher than 1500 Hz. An experiment measuring cutting force was completed lastly. The findings of the experiment confirm the viability of the dynamometer by demonstrating that it performs well and can identify changes in cutting force caused by two distinct cutting tools when operating under various conditions.
- 20 November 2022
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 46 (1) , 53-62
Development of the piezoelectric dynamometer for brittle material drilling
When processing deep and small holes in optical glass with a diamond core drill, the cutting force is minimal and very variable. It is challenging to measure the cutting force because of the high cutting frequency and small value of the cutting operation. In this study, a piezoelectric three-component dynamometer with excellent axial sensitivity is developed based on the measuring properties of quartz wafers and characteristics of cutting forces during processing. The dynamometer’s four sensors are positioned vertically, which could increase the dynamometer’s axial sensitivity. The dynamometer’s calibration studies were conducted in both static and dynamic modes. The output consists of the dynamometer was verified using a multi-point loading experiment. According to the experimental findings, the dynamometer’s linearity error and repeatability error are both less than 0.5%. Less than 1.6% and 2.9%, respectively, are found in the output error and crosstalk of multi-point loading experiment. The frequency of nature is higher than 1500 Hz. An experiment measuring cutting force was completed lastly. The findings of the experiment confirm the viability of the dynamometer by demonstrating that it performs well and can identify changes in cutting force caused by two distinct cutting tools when operating under various conditions.
- Open Access
- 4 May 2022
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 14 (5)
A positioning error compensation method for multiple degrees of freedom robot arm based on the measured and target position error
A novel positioning error compensation method (PECM) based on the measured and target position error for multiple degrees of freedom (DOF) robot arm control is proposed, which is used to improve positioning accuracy of multiple-DOF robot arm end-effector in accurate positioning applications such as in the medical and mechanical fields. Based on the idea of PID to increase adaptiveness and robustness of the method, a positioning compensation model between the measured and target position error tracked by an optical tracking system and compensated joint angle is derived with inverse kinematic model. Based on error analysis of the compensation model regarding geometry errors, the proportional joint angle compensated coefficient deduced from Jaccobian matrix of the error is proposed and identified with position error data. Calibration experiments for position conversion matrix and positioning accuracy verification experiments are conducted consisting of an optical tracking system and a robot arm. The results of positioning accuracy verification experiments show that the average resultant positioning error in three directions reduces from 1.89 mm (before compensation, model based on Denavit-Hartenberg (DH)), 0.39 mm (model based on modified Denavit-Hartenberg (MDH) with Levenberg-Marquardt (LM)) to 0.34 mm (decreasing 82%, 15%), which demonstrates the efficiency and robustness of the method.
- 4 May 2022
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 14 (5)
Open AccessA positioning error compensation method for multiple degrees of freedom robot arm based on the measured and target position error
A novel positioning error compensation method (PECM) based on the measured and target position error for multiple degrees of freedom (DOF) robot arm control is proposed, which is used to improve positioning accuracy of multiple-DOF robot arm end-effector in accurate positioning applications such as in the medical and mechanical fields. Based on the idea of PID to increase adaptiveness and robustness of the method, a positioning compensation model between the measured and target position error tracked by an optical tracking system and compensated joint angle is derived with inverse kinematic model. Based on error analysis of the compensation model regarding geometry errors, the proportional joint angle compensated coefficient deduced from Jaccobian matrix of the error is proposed and identified with position error data. Calibration experiments for position conversion matrix and positioning accuracy verification experiments are conducted consisting of an optical tracking system and a robot arm. The results of positioning accuracy verification experiments show that the average resultant positioning error in three directions reduces from 1.89 mm (before compensation, model based on Denavit-Hartenberg (DH)), 0.39 mm (model based on modified Denavit-Hartenberg (MDH) with Levenberg-Marquardt (LM)) to 0.34 mm (decreasing 82%, 15%), which demonstrates the efficiency and robustness of the method.
- 15 May 2020
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 20 (3) , 760-768
High-accuracy calibration method based on piezoelectric dynamometer for large vector force
High-accuracy measurement for vector force is essential in the process of industrial manufacture and control. Piezoelectric sensor has the characteristics of high frequency and stiffness, great dynamic response and resistance to harsh conditions, which are widely used to measure vector force. To solve the problem that vector force calibration device (VFCD) is difficult to comprehensively calibrate vector force test system (VFTS), a multi-station calibration method is proposed. Taking the six degree-of-freedom of vertical large VFCD as an example, mechanical model of vector force is established after matching output voltage and force value of piezoelectric dynamometer. Multi-station deflection calibration experiment is performed, and a fitting circle method is proposed to fit vector force parameters of multi-station under different step-force loadings. Finally, the results show that error of multi-station vector force calibration is less than 2%, which proves rationality of the calibration method. The error of fitting radius obtained by fitting circle method is less than 3.4%, which further verifies reliability of the calibration method, and provides a guarantee for VFTS to accurately measure vector force.
- 15 May 2020
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 20 (3) , 760-768
High-accuracy calibration method based on piezoelectric dynamometer for large vector force
High-accuracy measurement for vector force is essential in the process of industrial manufacture and control. Piezoelectric sensor has the characteristics of high frequency and stiffness, great dynamic response and resistance to harsh conditions, which are widely used to measure vector force. To solve the problem that vector force calibration device (VFCD) is difficult to comprehensively calibrate vector force test system (VFTS), a multi-station calibration method is proposed. Taking the six degree-of-freedom of vertical large VFCD as an example, mechanical model of vector force is established after matching output voltage and force value of piezoelectric dynamometer. Multi-station deflection calibration experiment is performed, and a fitting circle method is proposed to fit vector force parameters of multi-station under different step-force loadings. Finally, the results show that error of multi-station vector force calibration is less than 2%, which proves rationality of the calibration method. The error of fitting radius obtained by fitting circle method is less than 3.4%, which further verifies reliability of the calibration method, and provides a guarantee for VFTS to accurately measure vector force.
- 5 April 2020
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 20 (3) , 769-780
Research on effect of seed crystal on piezoelectric effect characteristics in quartz wafer
A multi-component measurement system centred on piezoelectric force sensor is an important mechanical measurement device, in which the piezoelectric sensor is mainly composed of force-sensitive components. The force-electric conversion performance of quartz wafer containing seed crystal and quartz crystal wafers is the main issue of the research in this paper. In the way of microscopic imaging and X-ray diffraction spectrum analysis, based on macroscopic physical properties of crystals, the theoretical basis of piezoelectric effects and the Neumann principle of elastic mechanics, both kinds of crystals have the same matrix of positive piezoelectric effects. Through static and continuous loading tests on quartz wafer containing seed crystal and ordinary quartz wafer, the maximum deviation of the electric charge, respectively, generated by X0° and Y0°cut type seed crystal wafers and ordinary quartz wafer in the static test under the same vector force loading is finally obtained, both seed-containing wafer and ordinary quartz wafer have excellent linearity. In continuous loading test, seed-containing wafer also has good continuous loading performance and can maintain a stable charge output under quasi-static input. Therefore, it is concluded that seed crystal wafers can also be used for actual testing.
- 5 April 2020
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 20 (3) , 769-780
Research on effect of seed crystal on piezoelectric effect characteristics in quartz wafer
A multi-component measurement system centred on piezoelectric force sensor is an important mechanical measurement device, in which the piezoelectric sensor is mainly composed of force-sensitive components. The force-electric conversion performance of quartz wafer containing seed crystal and quartz crystal wafers is the main issue of the research in this paper. In the way of microscopic imaging and X-ray diffraction spectrum analysis, based on macroscopic physical properties of crystals, the theoretical basis of piezoelectric effects and the Neumann principle of elastic mechanics, both kinds of crystals have the same matrix of positive piezoelectric effects. Through static and continuous loading tests on quartz wafer containing seed crystal and ordinary quartz wafer, the maximum deviation of the electric charge, respectively, generated by X0° and Y0°cut type seed crystal wafers and ordinary quartz wafer in the static test under the same vector force loading is finally obtained, both seed-containing wafer and ordinary quartz wafer have excellent linearity. In continuous loading test, seed-containing wafer also has good continuous loading performance and can maintain a stable charge output under quasi-static input. Therefore, it is concluded that seed crystal wafers can also be used for actual testing.
- 10 October 2019
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 142 (1)
A High-Accuracy Calibration Method Using Sensor Sensitivity Difference for Piezoelectric Dynamometer
High-accuracy measurement of force affects real-time control and process adjustment of industrial production. Piezoelectric sensor can be applied to measure force with the characteristics of high frequency and stiffness, great dynamic response and resistance to harsh conditions. As an important part of test, calibration determines sensitivity coefficient which directly affects test accuracy. To improve the calibration accuracy of offset loading force for multisensor piezoelectric dynamometer, a novel calibration method using sensor sensitivity difference is proposed in this paper. The calibration experiments of four sensors are performed to obtain the axial sensitivities and the force-to-electricity conversion coefficients. The multiple loading-point (MLP) calibration experiments of dynamometer are carried out, and the calibration results prove that the sensitivity difference of four sensors is the main reason affecting the calibration accuracy. The sensitivity difference calibration method (SDCM) is applied to the MLP calibration experiments, and the results show that the average resultant force deviations are reduced from 418.79 N (8.38% full scare (FS) to 24.16 N (0.61% FS) under a loading force of 5000 N, which proves high accuracy and reliability of SDCM. The calibration method will provide guidance for improving the calibration accuracy of dynamometer.
- 10 October 2019
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 142 (1)
A High-Accuracy Calibration Method Using Sensor Sensitivity Difference for Piezoelectric Dynamometer
High-accuracy measurement of force affects real-time control and process adjustment of industrial production. Piezoelectric sensor can be applied to measure force with the characteristics of high frequency and stiffness, great dynamic response and resistance to harsh conditions. As an important part of test, calibration determines sensitivity coefficient which directly affects test accuracy. To improve the calibration accuracy of offset loading force for multisensor piezoelectric dynamometer, a novel calibration method using sensor sensitivity difference is proposed in this paper. The calibration experiments of four sensors are performed to obtain the axial sensitivities and the force-to-electricity conversion coefficients. The multiple loading-point (MLP) calibration experiments of dynamometer are carried out, and the calibration results prove that the sensitivity difference of four sensors is the main reason affecting the calibration accuracy. The sensitivity difference calibration method (SDCM) is applied to the MLP calibration experiments, and the results show that the average resultant force deviations are reduced from 418.79 N (8.38% full scare (FS) to 24.16 N (0.61% FS) under a loading force of 5000 N, which proves high accuracy and reliability of SDCM. The calibration method will provide guidance for improving the calibration accuracy of dynamometer.
- 29 July 2019
- Published by Springer Nature in Experimental Techniques
- Vol. 44 (1) , 85-98
Rotation Calibration Method for Thrust Based on Force Error Analysis
- 29 July 2019
- Published by Springer Nature in Experimental Techniques
- Vol. 44 (1) , 85-98
Rotation Calibration Method for Thrust Based on Force Error Analysis