Christian Seifert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian Seifert has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christoph Braig
Institute for Applied Photonics eV, Rudower Chaussee 29/31, 12489 Berlin, Germany
1 shared publication - Heike Löchel
NOB Nano Optics Berlin GmbH, Krumme Straße 64, 10627 Berlin, Germany
1 shared publication - Jürgen Probst
NOB Nano Optics Berlin GmbH 4 , Krumme Straße 64, 10627 Berlin
1 shared publication - Ladislav Pina
Rigaku Innovative Technologies Europe s.r.o., Novodvorska 994, 142 21 Prague, Czech Republic
1 shared publication Thomas Krist
NOB Nano Optics Berlin GmbH, Krumme Straße 64, 10627 Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 6 June 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (4) , 690-697
Soft X-ray wavefront sensing at an ellipsoidal mirror shell
A reliable `in situ' method for wavefront sensing in the soft X-ray domain is reported, developed for the characterization of rotationally symmetric optical elements, like an ellipsoidal mirror shell. In a laboratory setup, the mirror sample is irradiated by an electron-excited (4.4 keV), micrometre-sized (∼2 µm) fluorescence source (carbonKα, 277 eV). Substantially, the three-dimensional intensity distributionI(r) is recorded by a CCD camera (2048 × 512 pixels of 13.5 µm) at two positions along the optical axis, symmetrically displaced by ±21–25% from the focus. The transport-of-intensity equation is interpreted in a geometrical sense from plane to plane and implemented as a ray tracing code, to retrieve the phase Φ(r) from the radial intensity gradient on a sub-pixel scale. For reasons of statistical reliability, five intra-/extra-focal CCD image pairs are evaluated and averaged to an annular two-dimensional map of the wavefront error {\cal W}. In units of the test wavelength (C Kα), an r.m.s. value \sigma_{\cal{W}} = ±10.9λ0and a peak-to-valley amplitude of ±31.3λ0are obtained. By means of the wavefront, the focus is first reconstructed with a result for its diameter of 38.4 µm, close to the direct experimental observation of 39.4 µm (FWHM). Secondly, figure and slope errors of the ellipsoid are characterized with an average of ±1.14 µm and ±8.8 arcsec (r.m.s.), respectively, the latter in reasonable agreement with the measured focal intensity distribution. The findings enable, amongst others, the precise alignment of axisymmetric X-ray mirrors or the design of a wavefront corrector for high-resolution X-ray science.
- 6 June 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (4) , 690-697
Open AccessSoft X-ray wavefront sensing at an ellipsoidal mirror shell
A reliable `in situ' method for wavefront sensing in the soft X-ray domain is reported, developed for the characterization of rotationally symmetric optical elements, like an ellipsoidal mirror shell. In a laboratory setup, the mirror sample is irradiated by an electron-excited (4.4 keV), micrometre-sized (∼2 µm) fluorescence source (carbonKα, 277 eV). Substantially, the three-dimensional intensity distributionI(r) is recorded by a CCD camera (2048 × 512 pixels of 13.5 µm) at two positions along the optical axis, symmetrically displaced by ±21–25% from the focus. The transport-of-intensity equation is interpreted in a geometrical sense from plane to plane and implemented as a ray tracing code, to retrieve the phase Φ(r) from the radial intensity gradient on a sub-pixel scale. For reasons of statistical reliability, five intra-/extra-focal CCD image pairs are evaluated and averaged to an annular two-dimensional map of the wavefront error {\cal W}. In units of the test wavelength (C Kα), an r.m.s. value \sigma_{\cal{W}} = ±10.9λ0and a peak-to-valley amplitude of ±31.3λ0are obtained. By means of the wavefront, the focus is first reconstructed with a result for its diameter of 38.4 µm, close to the direct experimental observation of 39.4 µm (FWHM). Secondly, figure and slope errors of the ellipsoid are characterized with an average of ±1.14 µm and ±8.8 arcsec (r.m.s.), respectively, the latter in reasonable agreement with the measured focal intensity distribution. The findings enable, amongst others, the precise alignment of axisymmetric X-ray mirrors or the design of a wavefront corrector for high-resolution X-ray science.