DRDaniel Santiago Rondón

Daniel Santiago Rondón

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Santiago Rondón has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Interactive posture program: a software platform for using the realistic anthropomorphic flexible phantom family in computational dosimetry applications

    by Pasquale Alessandro Lombardo, Dabin Jérémie, Mahmoud Abdelrahman, Daniel Santiago Rondon, Filip Vanhavere, Lara Struelens

    Boundary-representation (B-Rep) computational phantoms (CPs) offer high flexibility and anatomical accuracy, making them valuable tools in dosimetry and medical imaging simulations. However, their complexity and the need for expertise in graphic modelling limit their accessibility and adoption. Moreover, most Monte Carlo (MC) particle transport codes lack native support for B-Rep geometries, requiring complex and non-automated conversion to compatible formats, further complicating their use. To address these challenges, we developed the interactive posture program (IPP), a software platform to ease the use of B-Rep phantoms. The IPP features a real-time three-dimensional (3D) graphical interface, allowing users to easily create individualised phantoms and realistic exposure scenarios. Currently, the IPP includes three flexible phantoms—Adult Male, Adult Female, and 1-year-old Female—from the realistic anthropomorphic flexible (RAF) family, which can be extensively customised using integrated morphing tools to simulate diverse anatomical variations. Additionally, the IPP provides a comprehensive library of predefined exposure scenarios and advanced geometry creation tools, which allow the creation of accurate and individualised simulations. Finally, the IPP automatically generates simulation input files compatible with the most widely used MC transport codes, significantly simplifying the use of B-Rep phantoms within dosimetry and imaging simulations.


  • Computational system for extremity dosimetry in nuclear medicine

    by Daniel Santiago Rondón, Pasquale Lombardo, Mahmoud Abdelrahman, Lara Struelens, Filip Vanhavere, Werner Schoonjans, Niki Bergans

    The goal of this research is to create a computational dosimetry system to monitor the dose received by nuclear medicine workers on their extremities. The system creates multiple Monte Carlo simulations to assess the dose received in different sections of the hands. Each simulation is created based on depth camera images of the manipulation of radioactive sources, using digital twins to represent the hands of the worker and the radiation source. The position of the hands and the source is constantly recalculated using computer vision algorithms. In this paper, we explain the different components of the computational system, assessing the possible sources of uncertainty introduced by each component. As a proof of concept, we compared the dose estimated by the computational system with real dosimeter measurements for two different scenarios. The simulated dose was, on average, 51% of the measured dose.


  • Object and person tracking systems to enable extremity dosimetry in nuclear medicine using computational methods

    by Daniel Santiago Rondón, Pasquale Lombardo, Mahmoud Abdelrahman, Lara Struelens, Filip Vanhavere, Niki Bergans

    Nuclear medicine (NM) professionals are potentially exposed to high doses of ionising radiation, particularly in the skin of the hands. Ring dosimeters are used by the workers to ensure extremity doses are kept below the legal limits. However, ring dosimeters are often susceptible to large uncertainties, so it is difficult to ensure a correct measurement using the traditional occupational monitoring methods. An alternative solution is to calculate the absorbed dose by using Monte Carlo simulations. This method could reduce the uncertainty in dose calculation if the exact positions of the worker and the radiation source are represented in these simulations. In this study we present a set of computer vision and artificial intelligence algorithms that allow us to track the exact position of unshielded syringes and the hands of NM workers. We showcase a possible hardware configuration to acquire the necessary input data for the algorithms. And finally, we assess the tracking confidence of our software. The tracking accuracy achieved for the syringe detection was 57% and for the hand detection 98%.