Nurgül Çetin Tuncer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nurgül Çetin Tuncer has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Çağatay Barutçugil
Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
6 shared publications - Ayşe Dündar
Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University
3 shared publications - Nilay Bayraktar
Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
3 shared publications - Sergen Özdemir
Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
2 shared publications - Ayşegül Hezer
Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
1 shared publication - Deniz Tayfun
Private Clinic
1 shared publication
Latest Publications
- Open Access
- 14 November 2026
- Published by Springer Nature in BMC Oral Health
Optical behavior of permanent 3D-printed and CAD/CAM restorative materials after different polishing and aging conditions
- 14 November 2026
- Published by Springer Nature in BMC Oral Health
Open AccessOptical behavior of permanent 3D-printed and CAD/CAM restorative materials after different polishing and aging conditions
- Open Access
- 3 June 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Comparative Evaluation of the Effect of Different Polishing Systems on Surface Roughness of Permanent 3D ‐Printed Resins and a CAD / CAM Restorative Material
Objective: This study evaluated the effects of polishing systems, staining solutions, and aging time on the surface roughness of Computer‐aided design and computer‐aided manufacturing (CAD/CAM) and three‐dimensional (3D)‐printed permanent restorative materials. Methods: Three 3D‐printed resins (VarseoSmile Crown plus (VSC), Saremco PrintCrowntec (SC), Formlabs Permanent Crown (FC)) and one CAD/CAM block (GB) were included ( n = 150; n = 10/group). CAD/CAM specimens were sectioned from blocks, while 3D‐printed specimens were fabricated using DLP and SLA printers. Each material was divided into five subgroups: control (unpolished), Sof‐Lex (PS1), Composoft (PS2), Diacomp Plus TWIST (PS3), and Lucida DiaShine (PS4). Surface roughness (Ra) was measured before and after polishing and after storage in distilled water, coffee, and red wine for 24 h, 1 week, and 1 month. Data were analyzed using two‐way ANOVA and Tukey HSD tests ( α = 0.05). Results: Polishing significantly reduced surface roughness in all materials initially. Over time, Ra values increased, particularly in coffee and red wine. Control groups showed higher roughness than polished specimens. PS1 and PS3 generally yielded smoother surfaces, whereas PS2 often resulted in higher Ra values. Conclusion: Polishing improves surface smoothness; however, staining solutions and aging increase roughness, indicating that both polishing protocols and storage conditions affect material stability. Clinical Significance: Surface roughness of restorative materials is influenced by polishing protocols, material type, and exposure to staining beverages. Appropriate polishing procedures result in smoother surfaces; however, surface degradation occurs following exposure to commonly consumed beverages such as coffee and red wine. These findings highlight the importance of selecting effective polishing systems and considering the long‐term effects of dietary habits when using 3D‐printed and CAD/CAM restorative materials.
- 3 June 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessComparative Evaluation of the Effect of Different Polishing Systems on Surface Roughness of Permanent 3D ‐Printed Resins and a CAD / CAM Restorative Material
Objective: This study evaluated the effects of polishing systems, staining solutions, and aging time on the surface roughness of Computer‐aided design and computer‐aided manufacturing (CAD/CAM) and three‐dimensional (3D)‐printed permanent restorative materials. Methods: Three 3D‐printed resins (VarseoSmile Crown plus (VSC), Saremco PrintCrowntec (SC), Formlabs Permanent Crown (FC)) and one CAD/CAM block (GB) were included ( n = 150; n = 10/group). CAD/CAM specimens were sectioned from blocks, while 3D‐printed specimens were fabricated using DLP and SLA printers. Each material was divided into five subgroups: control (unpolished), Sof‐Lex (PS1), Composoft (PS2), Diacomp Plus TWIST (PS3), and Lucida DiaShine (PS4). Surface roughness (Ra) was measured before and after polishing and after storage in distilled water, coffee, and red wine for 24 h, 1 week, and 1 month. Data were analyzed using two‐way ANOVA and Tukey HSD tests ( α = 0.05). Results: Polishing significantly reduced surface roughness in all materials initially. Over time, Ra values increased, particularly in coffee and red wine. Control groups showed higher roughness than polished specimens. PS1 and PS3 generally yielded smoother surfaces, whereas PS2 often resulted in higher Ra values. Conclusion: Polishing improves surface smoothness; however, staining solutions and aging increase roughness, indicating that both polishing protocols and storage conditions affect material stability. Clinical Significance: Surface roughness of restorative materials is influenced by polishing protocols, material type, and exposure to staining beverages. Appropriate polishing procedures result in smoother surfaces; however, surface degradation occurs following exposure to commonly consumed beverages such as coffee and red wine. These findings highlight the importance of selecting effective polishing systems and considering the long‐term effects of dietary habits when using 3D‐printed and CAD/CAM restorative materials.
- 27 March 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 16 (1) , 181-189
Effect of Expiry Date on the Degree of Conversion, Microhardness, Depth of Cure, Water Absorption and Color Stability of Resin Composite
Objectives: To evaluate the degree of conversion, microhardness, curing depth, water absorption and color stability of expired and non-expired resin composite materials.Methods: Five different resin-based materials, Ceram.X Spheretec One (CRX), Beautiful II (BEA), SonicFill 2 (SCF), GrandioSo Heavy Flow (GSF) and SDR, with and without expiry dates, were used in the study. The degree of conversion was analyzed using ATR-FTIR spectrometer. For microhardness measurement, Vickers hardness test device was used. Microhardness of the RBCs was measured at 0.5 mm intervals starting from the top surface towards the bottom layer for depth cure measurement. Samples were immersed in water for water sorption analysis and in red wine and coffee for one week for color stability analysis. Statistical analysis was performed using one-way ANOVA, independent sample t-test, Tukey HSD test, Kruskal-Wallis, Mann-Whitney U test.Results: Only in the BEA group did expired samples show a lower degree of conversion and microhardness (bottom/top) than non-expired samples (p
- 27 March 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 16 (1) , 181-189
Effect of Expiry Date on the Degree of Conversion, Microhardness, Depth of Cure, Water Absorption and Color Stability of Resin Composite
Objectives: To evaluate the degree of conversion, microhardness, curing depth, water absorption and color stability of expired and non-expired resin composite materials.Methods: Five different resin-based materials, Ceram.X Spheretec One (CRX), Beautiful II (BEA), SonicFill 2 (SCF), GrandioSo Heavy Flow (GSF) and SDR, with and without expiry dates, were used in the study. The degree of conversion was analyzed using ATR-FTIR spectrometer. For microhardness measurement, Vickers hardness test device was used. Microhardness of the RBCs was measured at 0.5 mm intervals starting from the top surface towards the bottom layer for depth cure measurement. Samples were immersed in water for water sorption analysis and in red wine and coffee for one week for color stability analysis. Statistical analysis was performed using one-way ANOVA, independent sample t-test, Tukey HSD test, Kruskal-Wallis, Mann-Whitney U test.Results: Only in the BEA group did expired samples show a lower degree of conversion and microhardness (bottom/top) than non-expired samples (p
- Open Access
- 29 March 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (7) , 1920-1929
Evaluation of Polymerization Shrinkage, Microhardness, and Depth of Cure of Different Types of Bulk‐Fill Composites
Objectives: This study aimed to quantify polymerization shrinkage, microhardness, and depth of cure of different types of bulk‐fill composites. Methods: Six bulk‐fill composites were tested: SonicFill 2 (SCF), VisCalor (VVC), Admira Fusion x‐tra (AFX), Filtek Bulk Fill (FBF), Fill‐Up! (FUP) and GrandioSO Heavy Flow (GHF). Sixty teeth were divided into twelve groups ( n = 5) according to the composite and the irradiation level applied (standard or high). Each tooth was subjected to three scans using a micro‐computed tomography device. The microhardness of the composite specimens was measured using a Vickers hardness tester. Depth of cure analysis was performed by measuring the microhardness of the composites at 0.5 mm intervals from the top surface to the bottom surface. Results: The highest volumetric shrinkage was found in the AFX group when polymerized at standard irradiance. After curing, the AFX group showed the highest void ratio. Increasing irradiance significantly increased volumetric shrinkage and void ratio only in the SCF group ( p < 0.05). GHF achieved the maximum microhardness value of 80% at the lowest curing depth of 2.9 mm, while VVC, AFX, and SCF showed a curing depth of more than 5 mm ( p < 0.05). Conclusions: The high irradiance caused the most significant volumetric shrinkage and void ratio in the SCF group. Only the FUP and GHF groups were unable to achieve the desired curing depth of 4 mm. Clinical Relevance: Irradiance, material types, and thickness are important factors in the polymerization of composites.
- 29 March 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (7) , 1920-1929
Open AccessEvaluation of Polymerization Shrinkage, Microhardness, and Depth of Cure of Different Types of Bulk‐Fill Composites
Objectives: This study aimed to quantify polymerization shrinkage, microhardness, and depth of cure of different types of bulk‐fill composites. Methods: Six bulk‐fill composites were tested: SonicFill 2 (SCF), VisCalor (VVC), Admira Fusion x‐tra (AFX), Filtek Bulk Fill (FBF), Fill‐Up! (FUP) and GrandioSO Heavy Flow (GHF). Sixty teeth were divided into twelve groups ( n = 5) according to the composite and the irradiation level applied (standard or high). Each tooth was subjected to three scans using a micro‐computed tomography device. The microhardness of the composite specimens was measured using a Vickers hardness tester. Depth of cure analysis was performed by measuring the microhardness of the composites at 0.5 mm intervals from the top surface to the bottom surface. Results: The highest volumetric shrinkage was found in the AFX group when polymerized at standard irradiance. After curing, the AFX group showed the highest void ratio. Increasing irradiance significantly increased volumetric shrinkage and void ratio only in the SCF group ( p < 0.05). GHF achieved the maximum microhardness value of 80% at the lowest curing depth of 2.9 mm, while VVC, AFX, and SCF showed a curing depth of more than 5 mm ( p < 0.05). Conclusions: The high irradiance caused the most significant volumetric shrinkage and void ratio in the SCF group. Only the FUP and GHF groups were unable to achieve the desired curing depth of 4 mm. Clinical Relevance: Irradiance, material types, and thickness are important factors in the polymerization of composites.
- Open Access
- 1 January 2024
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 66 (3) , 157-162
Bacterial adhesion and surface properties of computer-aided design-computer-aided manufacturing restorative materials
Purpose: This study aimed to evaluate the surface properties and bacterial adhesion of computer-aided design-computer-aided manufacturing (CAD-CAM) restorative materials.Methods: Four CAD-CAM resin-based blocks (Vita Enamic, Shofu block HC, Cerasmart [CS] and Lava Ultimate [LU]) and a leucite-reinforced glass ceramic block (IPS Empress CAD) were used in the present study. Specimens prepared with dimensions of 10 × 10 × 1 mm were polished. Surface characteristics were assessed with hydrophobicity and surface free energy (SFE) analysis. Surface roughness was measured using a profilometer, and elemental and topographic evaluations were performed with SEM-EDX analysis. After being kept in artificial saliva for 1 h, Streptococcus mutans (S. mutans) and Streptococcus mitis (S. mitis) were incubated separately in 5% CO2 atmosphere at 37°C for 24 h. The adhered bacteria were counted as ×108 CFU/mL.Results: Surface roughness, contact angle and SFE measurement values were found to be in the range of 0.144-0.264 Ra, 28.362°-70.074° and 39.65-63.62 mN/m, respectively. The highest adhered amount of S. mutans was found in CS and the lowest in LU, while there was no significant difference between the amounts of adhered S. mitis.Conclusion: Despite differences in the surface properties of the materials used for the study, the materials exhibited identical properties with respect to bacterial adhesion.
- 1 January 2024
- Published by Nihon University School of Dentistry in Journal of Oral Science
- Vol. 66 (3) , 157-162
Open AccessBacterial adhesion and surface properties of computer-aided design-computer-aided manufacturing restorative materials
Purpose: This study aimed to evaluate the surface properties and bacterial adhesion of computer-aided design-computer-aided manufacturing (CAD-CAM) restorative materials.Methods: Four CAD-CAM resin-based blocks (Vita Enamic, Shofu block HC, Cerasmart [CS] and Lava Ultimate [LU]) and a leucite-reinforced glass ceramic block (IPS Empress CAD) were used in the present study. Specimens prepared with dimensions of 10 × 10 × 1 mm were polished. Surface characteristics were assessed with hydrophobicity and surface free energy (SFE) analysis. Surface roughness was measured using a profilometer, and elemental and topographic evaluations were performed with SEM-EDX analysis. After being kept in artificial saliva for 1 h, Streptococcus mutans (S. mutans) and Streptococcus mitis (S. mitis) were incubated separately in 5% CO2 atmosphere at 37°C for 24 h. The adhered bacteria were counted as ×108 CFU/mL.Results: Surface roughness, contact angle and SFE measurement values were found to be in the range of 0.144-0.264 Ra, 28.362°-70.074° and 39.65-63.62 mN/m, respectively. The highest adhered amount of S. mutans was found in CS and the lowest in LU, while there was no significant difference between the amounts of adhered S. mitis.Conclusion: Despite differences in the surface properties of the materials used for the study, the materials exhibited identical properties with respect to bacterial adhesion.