AKAnthony B. Kos
Anthony B. Kos
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anthony B. Kos has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Stephen E. Russek
National Institute of Standards and Technology (NIST) Boulder Colorado USA
2 shared publications - Hans T. Nembach
JILA, University of Colorado 1 , Boulder, Colorado 80309, USA
1 shared publication - Jacob J. Wisser
Department of Applied Physics, Stanford University 1 , Stanford, California 94305, USA
1 shared publication - Justin M. Shaw
National Institute of Standards and Technology
1 shared publication - Karl F. Stupic
National Institute of Standards and Technology, Physical Measurement Laboratory, Applied Physics Division, Boulder, CO 80305, USA
1 shared publication - Michael Tanksalvala
National Institute of Standards and Technology
1 shared publication
Latest Publications
- 20 June 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (6) , 064047
Element-specific high-bandwidth ferromagnetic resonance spectroscopy with a coherent extreme-ultraviolet source
In this paper, we apply a tabletop, ultrafast, high-harmonic generation (HHG) source to measure the element-specific ferromagnetic resonance (FMR) in ultrathin magnetic alloys and multilayers on an opaque substrate. We demonstrate a continuous-wave bandwidth up to 62 GHz, with a promise to extend it to 100 GHz or higher. This laboratory-scale instrument detects the FMR using ultrafast, extreme-ultraviolet (EUV) light, with photon energies spanning the M-edges of the most relevant magnetic elements. A radiofrequency frequency comb generator is used to produce a microwave excitation that is intrinsically synchronized to the EUV pulses with a timing jitter of 1.1 ps or better. We apply this system to measure the dynamics in a multilayer system as well as - and - alloys. Since this instrument operates in reflection mode, it is a milestone toward measuring and imaging the dynamics of the magnetic state and spin transport of active devices on arbitrary substrates on a tabletop. The higher bandwidth also enables measurements of materials with high magnetic anisotropy, as well as ferrimagnets, antiferromagnets, and short-wavelength (high-wavevector) spin waves in nanostructures or nanodevices. Furthermore, the coherence and short wavelength of the EUV will enable extending these studies using dynamic nanoscale lensless imaging techniques such as coherent diffractive imaging, ptychography, and holography.- 20 June 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (6) , 064047
Element-specific high-bandwidth ferromagnetic resonance spectroscopy with a coherent extreme-ultraviolet source
In this paper, we apply a tabletop, ultrafast, high-harmonic generation (HHG) source to measure the element-specific ferromagnetic resonance (FMR) in ultrathin magnetic alloys and multilayers on an opaque substrate. We demonstrate a continuous-wave bandwidth up to 62 GHz, with a promise to extend it to 100 GHz or higher. This laboratory-scale instrument detects the FMR using ultrafast, extreme-ultraviolet (EUV) light, with photon energies spanning the M-edges of the most relevant magnetic elements. A radiofrequency frequency comb generator is used to produce a microwave excitation that is intrinsically synchronized to the EUV pulses with a timing jitter of 1.1 ps or better. We apply this system to measure the dynamics in a multilayer system as well as - and - alloys. Since this instrument operates in reflection mode, it is a milestone toward measuring and imaging the dynamics of the magnetic state and spin transport of active devices on arbitrary substrates on a tabletop. The higher bandwidth also enables measurements of materials with high magnetic anisotropy, as well as ferrimagnets, antiferromagnets, and short-wavelength (high-wavevector) spin waves in nanostructures or nanodevices. Furthermore, the coherence and short wavelength of the EUV will enable extending these studies using dynamic nanoscale lensless imaging techniques such as coherent diffractive imaging, ptychography, and holography.- Open Access
- 21 March 2023
- Published by Elsevier in Journal of Magnetic Resonance Open
- Vol. 16-17, 100110
RF coil efficacy for efficient spin control in low field magnetic resonance experiments
- 21 March 2023
- Published by Elsevier in Journal of Magnetic Resonance Open
- Vol. 16-17, 100110
Open AccessRF coil efficacy for efficient spin control in low field magnetic resonance experiments
- 1 January 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 36 (1) , 159-165
Nanosecond magnetization reversal in high coercivity thin films
- 1 January 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 36 (1) , 159-165
Nanosecond magnetization reversal in high coercivity thin films
- 1 January 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 33 (5) , 3541-3543
High current density measurements of giant magnetoresistive spin-valves for magnetic recording and sensor applications
- 1 January 1997
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 33 (5) , 3541-3543
High current density measurements of giant magnetoresistive spin-valves for magnetic recording and sensor applications