YZYudi Zhang

Yudi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yudi Zhang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Displacement Estimation of Structures With Flag‐Shaped Hysteresis Loops

    by Yudi Zhang, Gregory A. MacRae, Geoffrey W. Rodgers, Shahab Ramhormozian, Charles Clifton, Masoumeh Farshbaf

    Time‐history analyses were conducted on single‐degree‐of‐freedom (SDOF) systems with flag‐shaped hysteresis loops using a far‐field ground motion suite to estimate peak displacements, Δ p , and equivalent deformation cycles, N c , associated with cumulative displacement demands. The varied parameters included loop dissipation parameters β (0.1 to 1), strength‐reduction factors R (2 to 8), positive post‐yield stiffness ratios r (0 to 0.9), structural periods T (0.2 s to 3.5 s), period‐to‐earthquake‐record‐duration ratios T / D (0.014 to 0.25), and viscous damping models. Empirical equations were proposed for the mean Δ p and N c . A comparison was made with responses of a three‐storey rocking structure with tension‐only friction dissipators (TOFDs). Using T / D instead of T improved displacement predictability for short‐period structures and gave similar accuracy for longer‐period structures. The greatest Δ p occurred in low‐dissipation structures with β = 0.1, r = 0.0, R = 8, and T / D = 0.014. Conventional displacement estimation methods may underpredict Δ p . The largest N c occurred for r = 0.9, β = 0.1, R = 8, and T / D = 0.014. Conservative equations were proposed for Δ p considering β , R , and T / D with r = 0.0, giving a coefficient of determination R 2 of 0.89. For N c , using r = 0.3 as a practical upper‐bound representative of common structures, conservative equations were proposed with R 2 of 0.91. The mean Δ p and cumulative TOFD displacement of the rocking structure subjected to the ground motion suite were similar to those from SDOF systems with matching β , R , r , and T . The empirical equations provided conservative predictions for the rocking‐structure responses.

  • Full‐Scale Shaking‐Table Evaluation of a Controlled Multiple‐Rocking‐Column System for Low‐Damage Seismic Performance

    by Yu‐Ao Lin, Zhenduo Yan, Hong‐Tai Zhang, Rui Zhang, Yudi Zhang, Ping Xiang, Xianzhong Zhao, Gregory A. MacRae, G. Charles Clifton, Geoffery Rodgers, et al.

    The growing demand for rapid post‐earthquake functional recovery and minimal structural damage has promoted the development of low‐damage seismic design strategies. Controlled rocking systems have emerged as an effective seismic structural solution for enhancing seismic resilience. To provide experimental evidence for the development of resilient steel structures, this study presents a full‐scale Controlled Multiple‐Rocking‐Column System (CMRCS) developed as part of the RObust BUilding SysTem (ROBUST) project. The system comprises two exterior controlled multiple‐rocking‐column frames and a central low‐damage secondary frame. The secondary frame carries the gravity loads assigned to Grid 2 and provides supplemental lateral resistance. Low‐damage rocking joints are installed at both ends of the rocking columns at each storey. Under frequently occurring earthquakes (FOEs), the CMRCS is designed to behave similarly to a conventional moment‐resisting steel frame, while the multiple‐rocking mechanism is intended to be activated at higher seismic intensities. Full‐scale shaking‐table tests were conducted on a 3‐storey steel frame specimen subjected to ground motions with peak ground accelerations (PGAs) ranging from 0.055 g to 0.62 g. The test results demonstrated that the structure exhibited satisfactory seismic performance, characterized by negligible residual drifts and no visible damage throughout the test sequence. Moreover, the proposed system also satisfied the immediate occupancy performance objective even under very rare earthquake‐level excitation (PGA of 0.62 g), thereby confirming the effectiveness, robustness and seismic resilience of the proposed system.

  • Top Cited Papers

    Shaking Table Behaviour of a Full‐Scale Three Storey Steel Rocking Structure With Tension‐Only Frictional Dissipators

    by Yudi Zhang, Gregory A. MacRae, Geoffrey W. Rodgers, Liangjiu Jia, Kiran Rangwani, Zhenduo Yan, Zheng Luo, Rajesh Shrestha, Aasish Tiwari, Yuao Lin, et al.

    A full‐scale three‐storey one‐bay‐by‐two‐bay steel rocking structure designed for the RObust BUilding SysTem (ROBUST) project consists of a central gravity frame (GF) and two exterior rocking frames (RFs) in the loading direction. Energy dissipation is provided by tension‐only friction dissipators and by moment connections in the beams extending from the central GF, which have the effect of partially restraining RF uplift. These beams, which span perpendicular to the loading direction, have nominally pinned connections adjacent to the exterior RFs and moment connections at the interface with the central GF. The moment connections on the two sides of the GF have different connection details with similar moment‐rotation loading characteristics but different unloading behaviour. Tests on the friction connection component of the tension‐only dissipators indicated that the sliding force varied during piecewise monotonic elongation. Shaking table tests with peak table accelerations up to 0.6 g exhibited RF uplift and showed the structure fully self‐centred with almost no damage. Despite similar loading characteristics, differences in unloading behaviour of the connections in the transverse beams on each side of the central GF caused significant floor plan torsion, and north and south RF peak absolute roof drifts of 0.92% and 0.42%, respectively. Three‐dimensional finite element model results matched the experimental behaviour well for the maximum applied shaking intensity. A parametric study using the experimental ground motion record showed roof displacements increased 54% due to the moment connection unloading difference, but this average value decreased to <8% considering multiple ground motion records.


  • Self-centering Rocking Steel Frame with Central Shear Key Design Considerations and Frame Seismic Performance

    by Yudi Zhang, Geoff Rodgers, Gregory A. MacRae, Liangjiu Jia, Kiran Rangwani, Zhenduo Yan, Yu’aO Lin, Wenhao Sun, G. Charles Clifton, Pierre Quenneville, et al.