Naixuan Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naixuan Zhu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Daozhuo Jiang
College of Electrical Engineering Zhejiang University Hangzhou People's Republic of China
2 shared publications- Pengfei Hu
School of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications Chongxi Jiang
Hangzhou Power Supply Company of State Grid Zhejiang Electric Power Co. Ltd. Hangzhou People's Republic of China
1 shared publication- Siqi Liu
College of Electrical Engineering Zhejiang University Hangzhou People's Republic of China
1 shared publication Yanxue Yu
College of Electrical Engineering Zhejiang University Hangzhou People's Republic of China
1 shared publicationYiqiao Liang
School of Information & Electrical Engineering Zhejiang University City College Hangzhou Zhejiang Province People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 2 September 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2416-2429
Comparative analysis and optimal allocation of virtual inertia from grid‐forming and grid‐following controlled ESSs
A broad consensus of neutralizing the carbon dioxide emissions facilitates the transition to the renewable energy power system. Meanwhile, the concerns about the volatility of renewable energies are growing as the rotational inertia of power system becomes inadequate. To maintain the frequency stability of power system, some studies for configuring inertia energy storage systems (ESSs) are carried out, mainly focusing on the allocation of virtual inertia from grid‐forming ESS. In contrast, the allocation of virtual inertia from grid‐following ESS has not been well elaborated and the differences in virtual inertia provided by these two modes are yet to be revealed. Based on ‐norm and Kron reduction, firstly, the state‐space model of post‐disturbance system is established, together with the transient performance evaluation. Then the inertia characteristics of both grid‐forming and grid‐following devices are formulated, followed by the unified gradient descent optimization method for allocating virtual inertia. A modified IEEE 39‐bus system and its time‐domain simulations help in the verification of the contribution of this paper. Through the comparative analysis of corresponding optimal results, the conclusions from two aspects are drawn: in terms of transient frequency support, the grid‐forming devices can provide no less than better inertia support; with the higher power capacity and similar energy capacity, the grid‐forming devices can relieve the response pressure of other generators by approximately .
- 2 September 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2416-2429
Open AccessComparative analysis and optimal allocation of virtual inertia from grid‐forming and grid‐following controlled ESSs
A broad consensus of neutralizing the carbon dioxide emissions facilitates the transition to the renewable energy power system. Meanwhile, the concerns about the volatility of renewable energies are growing as the rotational inertia of power system becomes inadequate. To maintain the frequency stability of power system, some studies for configuring inertia energy storage systems (ESSs) are carried out, mainly focusing on the allocation of virtual inertia from grid‐forming ESS. In contrast, the allocation of virtual inertia from grid‐following ESS has not been well elaborated and the differences in virtual inertia provided by these two modes are yet to be revealed. Based on ‐norm and Kron reduction, firstly, the state‐space model of post‐disturbance system is established, together with the transient performance evaluation. Then the inertia characteristics of both grid‐forming and grid‐following devices are formulated, followed by the unified gradient descent optimization method for allocating virtual inertia. A modified IEEE 39‐bus system and its time‐domain simulations help in the verification of the contribution of this paper. Through the comparative analysis of corresponding optimal results, the conclusions from two aspects are drawn: in terms of transient frequency support, the grid‐forming devices can provide no less than better inertia support; with the higher power capacity and similar energy capacity, the grid‐forming devices can relieve the response pressure of other generators by approximately .
- Open Access
- 23 September 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 16 (2) , 305-318
Emergency reserve constrained optimal allocation of energy storage in a novel honeycomb‐like microgrid cluster with volatile renewable energy resources
With the increasing penetration of large‐scale distributed renewable energies, the electricity distribution network is growing more complex with challenges brought by the intermittency and uncertainty of renewable energies. Microgrid (MG), one of feasible solutions to integrating renewable energies, has shortages because of limited capacity. Therefore, MG cluster (MGC) was proposed as an improved solution. To efficiently and friendly integrate renewable energies, a novel honeycomb‐like MG cluster (H‐MGC) is proposed in this paper. Considering the uncertainty of renewable energies, a robust optimisation method of the siting and sizing of energy storage system (ESS) constrained by emergency reserve is proposed. Combining the column‐and‐constraint generation algorithm and big‐M method, the proposed optimisation model is decomposed into mixed integer second‐order cone programming master problem and sub‐problems, which are alternately solved. Based on the optimal results of study case, the siting and sizing results of ESS are analysed, as well as the operating characteristics of H‐MGC. Compared to existing MGC system, the proposed H‐MGC has a more flexible operation mode. The related costs of ESS are reduced, and the operational life is relatively extended, under the condition that the emergency reserve of system is satisfied.
- 23 September 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 16 (2) , 305-318
Open AccessEmergency reserve constrained optimal allocation of energy storage in a novel honeycomb‐like microgrid cluster with volatile renewable energy resources
With the increasing penetration of large‐scale distributed renewable energies, the electricity distribution network is growing more complex with challenges brought by the intermittency and uncertainty of renewable energies. Microgrid (MG), one of feasible solutions to integrating renewable energies, has shortages because of limited capacity. Therefore, MG cluster (MGC) was proposed as an improved solution. To efficiently and friendly integrate renewable energies, a novel honeycomb‐like MG cluster (H‐MGC) is proposed in this paper. Considering the uncertainty of renewable energies, a robust optimisation method of the siting and sizing of energy storage system (ESS) constrained by emergency reserve is proposed. Combining the column‐and‐constraint generation algorithm and big‐M method, the proposed optimisation model is decomposed into mixed integer second‐order cone programming master problem and sub‐problems, which are alternately solved. Based on the optimal results of study case, the siting and sizing results of ESS are analysed, as well as the operating characteristics of H‐MGC. Compared to existing MGC system, the proposed H‐MGC has a more flexible operation mode. The related costs of ESS are reduced, and the operational life is relatively extended, under the condition that the emergency reserve of system is satisfied.