Evaluating the Efficacy of Shear Connectors in H Steel Sections Embedded in Concrete
This study is focusing on H steel sections embedded in concrete by evaluating various shear connectors, including headed studs, bolts, steel angles, perfobonds, and self-connected variants. This comprehensive examination of nine specimens aims to understand their load-bearing capacity, failure mechanisms, and overall performance in structural composite connections. The paper thoroughly compares and analyzes the load-slip curves, average initial shear stiffness, ultimate load, ductility, and fracture energy for these connectors. The research highlights self-connected connectors with rebars passing through flanges demonstrating substantial increases in ultimate load (41 %) in comparison to natural bond only, and maintaining ductility post-peak. Moreover, through this study it has been found that when shear studs and shear angles are designed for equivalent loads exhibit remarkably similar performance. Additionally, adding extra connectors to the web of H-sections enhances load capacity and stiffness but reduces ductility. The double shear in 10 mm diameter 8.8 bolted (with two nuts inside and outside flange) connectors raise the ultimate load but shift the curve of load slip from ductile to brittle in comparison with the same diameter studs.
- 1 March 2025
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 30 (1) , 125-134
Open AccessEvaluating the Efficacy of Shear Connectors in H Steel Sections Embedded in Concrete
This study is focusing on H steel sections embedded in concrete by evaluating various shear connectors, including headed studs, bolts, steel angles, perfobonds, and self-connected variants. This comprehensive examination of nine specimens aims to understand their load-bearing capacity, failure mechanisms, and overall performance in structural composite connections. The paper thoroughly compares and analyzes the load-slip curves, average initial shear stiffness, ultimate load, ductility, and fracture energy for these connectors. The research highlights self-connected connectors with rebars passing through flanges demonstrating substantial increases in ultimate load (41 %) in comparison to natural bond only, and maintaining ductility post-peak. Moreover, through this study it has been found that when shear studs and shear angles are designed for equivalent loads exhibit remarkably similar performance. Additionally, adding extra connectors to the web of H-sections enhances load capacity and stiffness but reduces ductility. The double shear in 10 mm diameter 8.8 bolted (with two nuts inside and outside flange) connectors raise the ultimate load but shift the curve of load slip from ductile to brittle in comparison with the same diameter studs.
- Open Access
- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Engineering
- Vol. 14 (1)
Evaluating the interaction for embedded H-steel section in normal concrete under monotonic and repeated loads
This article presents an experimental investigation into alternative strategies for enhancing the interaction of H-shaped steel sections embedded in normal reinforced concrete. Utilizing 12 push-out specimens subjected to monotonic and repeated loading, the study examines the natural bond-effecting parameters and shear transfer mechanisms facilitated by studs. Key parameters under investigation include embedded length, confinement stirrups, concrete cover, and variations in stud welding configurations, specifically welding to the flange and both the flange and web. In summary, a mathematical model for bond slip was proposed. In enhancing steel‒concrete interaction, adding 10-mm-diameter studs to both flanges and the web of the steel section is more effective than increasing the embedded depth by 67%. The second most effective method is doubling the concrete cover, followed by increasing the stirrups ratio by 40%. However, adding studs just to flanges outperforms solely increasing the stirrups ratio under repeated loading but does not match the effectiveness of other enhancement parameters. Yet notable shift from brittle to ductile behavior by introducing shear studs attached to flanges. The study also explores the influence of loading type on natural bond, noting lower values (13–18%) in ultimate load and (8–18)% in residual load capacities under repeated loading compared to monotonic loading, this drop is effectively mitigated by shear stud connections, particularly on the flange.
- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Engineering
- Vol. 14 (1)
Open AccessEvaluating the interaction for embedded H-steel section in normal concrete under monotonic and repeated loads
This article presents an experimental investigation into alternative strategies for enhancing the interaction of H-shaped steel sections embedded in normal reinforced concrete. Utilizing 12 push-out specimens subjected to monotonic and repeated loading, the study examines the natural bond-effecting parameters and shear transfer mechanisms facilitated by studs. Key parameters under investigation include embedded length, confinement stirrups, concrete cover, and variations in stud welding configurations, specifically welding to the flange and both the flange and web. In summary, a mathematical model for bond slip was proposed. In enhancing steel‒concrete interaction, adding 10-mm-diameter studs to both flanges and the web of the steel section is more effective than increasing the embedded depth by 67%. The second most effective method is doubling the concrete cover, followed by increasing the stirrups ratio by 40%. However, adding studs just to flanges outperforms solely increasing the stirrups ratio under repeated loading but does not match the effectiveness of other enhancement parameters. Yet notable shift from brittle to ductile behavior by introducing shear studs attached to flanges. The study also explores the influence of loading type on natural bond, noting lower values (13–18%) in ultimate load and (8–18)% in residual load capacities under repeated loading compared to monotonic loading, this drop is effectively mitigated by shear stud connections, particularly on the flange.