Iden Kurtaliaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Iden Kurtaliaj has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- David Ju
NSF Science and Technology Center for Engineering Mechanobiology, Saint Louis, USA
1 shared publication - Donghwan Yoon
Sibley School of Mechanical and Aerospace Engineering Cornell University Ithaca New York USA
1 shared publication Ethan D. Hoppe
NSF Science and Technology Center for Engineering Mechanobiology, Washington University in St. Louis, St. Louis, MO 63130, USA
1 shared publication- Guy M. Genin
NSF Science and Technology Center for Engineering Mechanobiology, Washington University in St. Louis, MO, USA
1 shared publication - Jacob A. Sandler
NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA
1 shared publication - Lester Jeshua Smith
Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA
1 shared publication
Latest Publications
- Open Access
- 28 June 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (26) , eadl5270
Python tooth–inspired fixation device for enhanced rotator cuff repair
Rotator cuff repair surgeries fail frequently, with 20 to 94% of the 600,000 repairs performed annually in the United States resulting in retearing of the rotator cuff. The most common cause of failure is sutures tearing through tendons at grasping points. To address this issue, we drew inspiration from the specialized teeth of snakes of the Pythonoidea superfamily, which grasp soft tissues without tearing. To apply this nondamaging gripping approach to the surgical repair of tendon, we developed and optimized a python tooth–inspired device as an adjunct to current rotator cuff suture repair and found that it nearly doubled repair strength. Integrated simulations, 3D printing, and ex vivo experiments revealed a relationship between tooth shape and grasping mechanics, enabling optimization of the clinically relevant device that substantially enhances rotator cuff repair by distributing stresses over the attachment footprint. This approach suggests an alternative to traditional suturing paradigms and may reduce the risk of tendon retearing after rotator cuff repair.
- 28 June 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (26) , eadl5270
Open AccessPython tooth–inspired fixation device for enhanced rotator cuff repair
Rotator cuff repair surgeries fail frequently, with 20 to 94% of the 600,000 repairs performed annually in the United States resulting in retearing of the rotator cuff. The most common cause of failure is sutures tearing through tendons at grasping points. To address this issue, we drew inspiration from the specialized teeth of snakes of the Pythonoidea superfamily, which grasp soft tissues without tearing. To apply this nondamaging gripping approach to the surgical repair of tendon, we developed and optimized a python tooth–inspired device as an adjunct to current rotator cuff suture repair and found that it nearly doubled repair strength. Integrated simulations, 3D printing, and ex vivo experiments revealed a relationship between tooth shape and grasping mechanics, enabling optimization of the clinically relevant device that substantially enhances rotator cuff repair by distributing stresses over the attachment footprint. This approach suggests an alternative to traditional suturing paradigms and may reduce the risk of tendon retearing after rotator cuff repair.