Xiao‐Hua Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xiao‐Hua Li has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Hong Min
Department of Chemistry , East China Normal University , Shanghai, China
1 shared publication- Litong Jin
Department of Chemistry, East China Normal University, Shanghai 200062, PR China
1 shared publication Yue‐Zhong Xian
Department of Chemistry , East China Normal University , Shanghai, China
1 shared publicationZong‐Hong Xie
Department of Chemistry , East China Normal University , Shanghai, China
1 shared publication
Latest Publications
- 11 February 2008
- Published by Taylor & Francis in Analytical Letters
- Vol. 41 (3) , 456-468
Amperometric Biosensor for Hypoxanthine Based on Immobilized Xanthine Oxidase on Iron (III)Meso‐tetraphenylporphyrin Nanoparticles Modified Glassy Carbon Electrode
The preparation and performance of hypoxanthine (Hx) electrochemical biosensor, which was based on iron (III) meso‐tetraphenylporphyrin (FeTPP) nanoparticles (NPs), is reported in this work. FeTPP NPs prepared by mixing solvent techniques with diameters ca. 25~45 nm and were used as a mediator. The XOD/FeTPPNP/GC electrode exhibited good amperometric signal for Hx. Based on the consumption of dissolved oxygen during the oxidation process of Hx catalyzed by the immobilized XOD, the biosensor could detect the concentration of Hx up to 0.34 mM with a detection limit of 1.0 µM. The usefulness of this biosensor for the analysis of real sample was also demonstrated by determining Hx in rat brain dialysate coupled with microdialysis.
- 11 February 2008
- Published by Taylor & Francis in Analytical Letters
- Vol. 41 (3) , 456-468
Amperometric Biosensor for Hypoxanthine Based on Immobilized Xanthine Oxidase on Iron (III)Meso‐tetraphenylporphyrin Nanoparticles Modified Glassy Carbon Electrode
The preparation and performance of hypoxanthine (Hx) electrochemical biosensor, which was based on iron (III) meso‐tetraphenylporphyrin (FeTPP) nanoparticles (NPs), is reported in this work. FeTPP NPs prepared by mixing solvent techniques with diameters ca. 25~45 nm and were used as a mediator. The XOD/FeTPPNP/GC electrode exhibited good amperometric signal for Hx. Based on the consumption of dissolved oxygen during the oxidation process of Hx catalyzed by the immobilized XOD, the biosensor could detect the concentration of Hx up to 0.34 mM with a detection limit of 1.0 µM. The usefulness of this biosensor for the analysis of real sample was also demonstrated by determining Hx in rat brain dialysate coupled with microdialysis.