Amperometric Biosensor for Hypoxanthine Based on Immobilized Xanthine Oxidase on Iron (III)Meso‐tetraphenylporphyrin Nanoparticles Modified Glassy Carbon Electrode
- 11 February 2008
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 41 (3) , 456-468
Abstract
The preparation and performance of hypoxanthine (Hx) electrochemical biosensor, which was based on iron (III) meso‐tetraphenylporphyrin (FeTPP) nanoparticles (NPs), is reported in this work. FeTPP NPs prepared by mixing solvent techniques with diameters ca. 25~45 nm and were used as a mediator. The XOD/FeTPPNP/GC electrode exhibited good amperometric signal for Hx. Based on the consumption of dissolved oxygen during the oxidation process of Hx catalyzed by the immobilized XOD, the biosensor could detect the concentration of Hx up to 0.34 mM with a detection limit of 1.0 µM. The usefulness of this biosensor for the analysis of real sample was also demonstrated by determining Hx in rat brain dialysate coupled with microdialysis.Keywords
This publication has 30 references indexed in Scilit:
- Amperometric sensor for glucose based on electrochemically polymerized tetraruthenated nickel-porphyrinAnalytica Chimica Acta, 2005
- Contractile responses in spontaneously diabetic mice: I. Involvement of superoxide anion in enhanced contractile response of aorta to norepinephrine in C57BL/KsJ(db/db) miceGeneral Pharmacology: The Vascular System, 2000
- Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized on a CuPtCl6 chemically modified electrode and liquid chromatography electrochemical detectionAnalytica Chimica Acta, 2000
- Molecular Assembly of Manganese Fluorinated Mesoporphyrin Monolayer on a Gold ElectrodeChemistry Letters, 2000
- Biosensor for detection of hypoxanthine based on xanthine oxidase immobilized on chemically modified carbon paste electrodeAnalytica Chimica Acta, 2000
- Microfabricated On-Line Sensor for Continuous Monitoring of l-GlutamateAnalytical Sciences, 1998
- Development of a bienzymic graphite–Teflon composite electrode for the determination of hypoxanthine in fishThe Analyst, 1998
- The nature of .pi.-.pi. interactionsJournal of the American Chemical Society, 1990
- Amperometric Determination of Hypoxanthine and Inosine by Use of Enzyme Sensors Based on a Clark-Type Hydrogen Peroxide or Oxygen ElectrodeAnalytical Letters, 1990
- Rotating-ring-disk analysis of iron tetra(N-methylpyridyl)porphyrin in electrocatalysis of oxygenAnalytical Chemistry, 1979