Yanxing Suo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanxing Suo has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Yang Zhao
School of Integrated Circuits, Shanghai Jiao Tong University, Shanghai, China
7 shared publications - Qiao Cai
Shanghai Jiao Tong University
5 shared publications - Yongfu Li
Shanghai Jiao Tong University
4 shared publications - Guoxing Wang
Shanghai Jiao Tong University
3 shared publications - Xinzi Xu
Shanghai Jiao Tong University,Department of Micro/Nano Electrorics,Shanghai,China
3 shared publications - Guanghua Qian
Shanghai Jiao Tong University
2 shared publications
Latest Publications
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (5) , 908-919
A 0.48$^{\circ}$ Phase Error 91.1 dB SNR Bioimpedance Measurement IC for Monitoring Cardiopulmonary Diseases
This article presents a low-power and low phase error bioimpedance (BioZ) measurement IC designed for monitoring cardiopulmonary diseases. To compensate for the phase shift introduced along the signal path by current generator (CG), electrodes and sensor analog front-end (AFE), a novel phase shift calibration logic is proposed. Utilizing this calibration logic, a single-channel in-phase demodulation-based impedance measurement scheme is developed. A noise shaping pseudo-sine wave CG with data-weighted averaging (DWA) is used to minimize modulation harmonics. Fabricated in a 0.18μm CMOS process, the chip occupies 0.73mm2 and consumes between 52.7 to 97.5μA current from a 1.8V supply. The CG achieves 74.1dB SFDR and –70dB THD at 15.5kHz with a 50μApk stimulation current. The chip achieves $2 \text{m} \Omega / \sqrt{} Hz$ input-referred impedance noise at 1Hz, 91.1dB SNR (BW=4Hz), $36 \text{k} \Omega$ input range and less than 0.48° phase error (0–90°, 1–20kHz). On-body BioZ experiments using a 4-electrode configuration demonstrate clear recordings of Impedance Cardiography (ICG) and respiration signals.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (5) , 908-919
A 0.48$^{\circ}$ Phase Error 91.1 dB SNR Bioimpedance Measurement IC for Monitoring Cardiopulmonary Diseases
This article presents a low-power and low phase error bioimpedance (BioZ) measurement IC designed for monitoring cardiopulmonary diseases. To compensate for the phase shift introduced along the signal path by current generator (CG), electrodes and sensor analog front-end (AFE), a novel phase shift calibration logic is proposed. Utilizing this calibration logic, a single-channel in-phase demodulation-based impedance measurement scheme is developed. A noise shaping pseudo-sine wave CG with data-weighted averaging (DWA) is used to minimize modulation harmonics. Fabricated in a 0.18μm CMOS process, the chip occupies 0.73mm2 and consumes between 52.7 to 97.5μA current from a 1.8V supply. The CG achieves 74.1dB SFDR and –70dB THD at 15.5kHz with a 50μApk stimulation current. The chip achieves $2 \text{m} \Omega / \sqrt{} Hz$ input-referred impedance noise at 1Hz, 91.1dB SNR (BW=4Hz), $36 \text{k} \Omega$ input range and less than 0.48° phase error (0–90°, 1–20kHz). On-body BioZ experiments using a 4-electrode configuration demonstrate clear recordings of Impedance Cardiography (ICG) and respiration signals.
- 6 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1160-1174
Artifact-Tolerant Electrophysiological Sensor Interface With 3.6V/1.8V DM/CM Input Range and 52.3mV pp /${\mu}$s Recovery Using Asynchronous Signal Folding
In the practical implementations of wearable sensors, motion artifacts with large amplitudes often cause signal chain saturation, significantly degrading biopotential signal integrity. Similarly, rapid stimulation artifacts are inevitable during closed-loop brain stimulation therapy, posing additional challenges for real-time signal acquisition. To address motion and stimulation artifacts with amplitudes reaching hundreds of mV while minimizing information loss, a sensor interface with high input range and fast artifacts recovery capability is essential. This paper presents a continuous-time track-and-zoom (CT-TAZ) technique designed to handle large artifacts events without saturation. The proposed system achieves a 3.6V/1.8V differential-mode/common-mode full-scale input range. Fabricated in a 180nm CMOS process, the prototype chip occupies an area of 0.694mm2 and consumes 12/32.6/51.6μW for recordings without/with single-end/ with differential rail-to-rail artifacts. The system demonstrates an average artifacts recovery time of 65.3 μs under 3.6V stimulation artifacts, achieving an average artifacts recovery speed of 52.3mVpp/μs, which is 2.25× larger input range and 3× faster recovery compared to the state-of-the-art.
- 6 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1160-1174
Artifact-Tolerant Electrophysiological Sensor Interface With 3.6V/1.8V DM/CM Input Range and 52.3mV pp /${\mu}$s Recovery Using Asynchronous Signal Folding
In the practical implementations of wearable sensors, motion artifacts with large amplitudes often cause signal chain saturation, significantly degrading biopotential signal integrity. Similarly, rapid stimulation artifacts are inevitable during closed-loop brain stimulation therapy, posing additional challenges for real-time signal acquisition. To address motion and stimulation artifacts with amplitudes reaching hundreds of mV while minimizing information loss, a sensor interface with high input range and fast artifacts recovery capability is essential. This paper presents a continuous-time track-and-zoom (CT-TAZ) technique designed to handle large artifacts events without saturation. The proposed system achieves a 3.6V/1.8V differential-mode/common-mode full-scale input range. Fabricated in a 180nm CMOS process, the prototype chip occupies an area of 0.694mm2 and consumes 12/32.6/51.6μW for recordings without/with single-end/ with differential rail-to-rail artifacts. The system demonstrates an average artifacts recovery time of 65.3 μs under 3.6V stimulation artifacts, achieving an average artifacts recovery speed of 52.3mVpp/μs, which is 2.25× larger input range and 3× faster recovery compared to the state-of-the-art.
- Open Access
- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Integrated Circuits and Systems
- Vol. 1 (4) , 239-246
A Multi-Channel 133-dB DR PPG/ECG SoC for Smart Wearable Devices
Real-time monitoring of multimodal vital signs including electrocardiography (ECG) and photoplethysmography (PPG) on wearable devices are attracting increasing interests. Motion artifacts, ambient light interference and sensor-skin contact variability affect signal quality significantly, demanding a multi-channel sensor interface chip with high dynamic range yet low power. A PPG/ECG interface chip is proposed for robust signal optimization. Time-division multiplexing, ambient double sampling and DC current compensation together enhance the dynamic range. Fabricated in a 0.18μm process, the chip features a 5.63-pArms direct digitized input-referred noise for PPG readout and 365-nVrms for ECG. A cross-scale dynamic range of 133dB is achieved, providing saturation-free usage for sport wearable devices such as smart watches and rings.
- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Integrated Circuits and Systems
- Vol. 1 (4) , 239-246
Open AccessA Multi-Channel 133-dB DR PPG/ECG SoC for Smart Wearable Devices
Real-time monitoring of multimodal vital signs including electrocardiography (ECG) and photoplethysmography (PPG) on wearable devices are attracting increasing interests. Motion artifacts, ambient light interference and sensor-skin contact variability affect signal quality significantly, demanding a multi-channel sensor interface chip with high dynamic range yet low power. A PPG/ECG interface chip is proposed for robust signal optimization. Time-division multiplexing, ambient double sampling and DC current compensation together enhance the dynamic range. Fabricated in a 0.18μm process, the chip features a 5.63-pArms direct digitized input-referred noise for PPG readout and 365-nVrms for ECG. A cross-scale dynamic range of 133dB is achieved, providing saturation-free usage for sport wearable devices such as smart watches and rings.
- Open Access
- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Integrated Circuits and Systems
- Vol. 1 (4) , 215-226
Wearable Sensors for Vital Signs: A Review of 20 Years and Future Directions
This paper presents a comprehensive review of the advancements of wearables over 20 years and explores future directions in the field. The review focuses on the evolving needs, innovation solutions, and technological progress of these sensors. We categorize the existing literature into key themes, highlighting significant advancements, challenges and future prospects in wearable sensor technology.
- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Integrated Circuits and Systems
- Vol. 1 (4) , 215-226
Open AccessWearable Sensors for Vital Signs: A Review of 20 Years and Future Directions
This paper presents a comprehensive review of the advancements of wearables over 20 years and explores future directions in the field. The review focuses on the evolving needs, innovation solutions, and technological progress of these sensors. We categorize the existing literature into key themes, highlighting significant advancements, challenges and future prospects in wearable sensor technology.
- Open Access
High‐density implantable neural electrodes and chips for massive neural recordings
High‐density neural recordings with superior spatiotemporal resolution powerfully unveil cellular‐scale neural communication, showing great promise in neural science, translational medicine, and clinical applications. To achieve such, many design and fabrication innovations enhanced the electrode, chip, or both for biocompatibility improvement, electrical performance upgrade, and size miniaturization, offering several thousands of recording sites. However, an enormous gap exists along the trajectory toward billions of recording sites for brain scale resolution, posing many more design challenges. This review tries to find possible insight into mitigating the gap by discussing the latest progress in high‐density electrodes and chips for neural recordings. It emphasizes the design, fabrication, bonding techniques, and in vivo performance optimization of high‐density electrodes. It discusses the promising opportunities for circuit‐level and architecture‐level multi‐channel chip design innovations. We expect that joint effort and close collaboration between high‐density electrodes and chips will pave the way to high‐resolution neural recording tools supporting cutting‐edge neuroscience discoveries and applications.
Open AccessHigh‐density implantable neural electrodes and chips for massive neural recordings
High‐density neural recordings with superior spatiotemporal resolution powerfully unveil cellular‐scale neural communication, showing great promise in neural science, translational medicine, and clinical applications. To achieve such, many design and fabrication innovations enhanced the electrode, chip, or both for biocompatibility improvement, electrical performance upgrade, and size miniaturization, offering several thousands of recording sites. However, an enormous gap exists along the trajectory toward billions of recording sites for brain scale resolution, posing many more design challenges. This review tries to find possible insight into mitigating the gap by discussing the latest progress in high‐density electrodes and chips for neural recordings. It emphasizes the design, fabrication, bonding techniques, and in vivo performance optimization of high‐density electrodes. It discusses the promising opportunities for circuit‐level and architecture‐level multi‐channel chip design innovations. We expect that joint effort and close collaboration between high‐density electrodes and chips will pave the way to high‐resolution neural recording tools supporting cutting‐edge neuroscience discoveries and applications.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
An Adaptive BPSK Modulated Wireless Inductive Link for Implantable Devices
Binary phase shift-keying (BPSK) modulation shows great potential for wireless data and power transmission via single inductive link. Conventional BPSK modulation suffers from the inefficiency of wasting modulation cycles on bits that remain unchanged. An adaptive BPSK (A-BPSK) encoding-decoding mechanism is proposed in this paper to encode the unchanged bits with merely one carrier cycle, greatly enhancing the transmission capacity. Applying on a Class-E inductive link, an A-BPSK wireless transmission chipset is implemented in a 0.18μm BCD process. At a 13.56MHz carrier, post-layout simulation shows a minimum and maximum data rates of 3.87Mbps and 13.56Mbps, respectively. Statistically, the average data rate can be 6.02Mbps showing 2X over speed up.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
An Adaptive BPSK Modulated Wireless Inductive Link for Implantable Devices
Binary phase shift-keying (BPSK) modulation shows great potential for wireless data and power transmission via single inductive link. Conventional BPSK modulation suffers from the inefficiency of wasting modulation cycles on bits that remain unchanged. An adaptive BPSK (A-BPSK) encoding-decoding mechanism is proposed in this paper to encode the unchanged bits with merely one carrier cycle, greatly enhancing the transmission capacity. Applying on a Class-E inductive link, an A-BPSK wireless transmission chipset is implemented in a 0.18μm BCD process. At a 13.56MHz carrier, post-layout simulation shows a minimum and maximum data rates of 3.87Mbps and 13.56Mbps, respectively. Statistically, the average data rate can be 6.02Mbps showing 2X over speed up.