Xinhao Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xinhao Chen has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Axel Krieger
Department of Mechanical Engineering, Johns Hopkins University, Baltimore, USA
5 shared publications - Anuruddha Bhattacharjee
Johns Hopkins University, Baltimore, MD, USA
3 shared publications - Lamar O. Mair
Division of Magnetic Manipulation and Particle Research Weinberg Medical Physics, Inc. Rockville Maryland USA
3 shared publications - Suraj Raval
Department of Mechanical Engineering, University of Maryland, College Park, MD 20742, USA
3 shared publications - Yancy Diaz-Mercado
Department of Mechanical Engineering University of Maryland College Park Maryland USA
3 shared publications - Adam May
Department of Biomedical Engineering Johns Hopkins University Baltimore Maryland USA
1 shared publication
Latest Publications
- 28 September 2026
- Published by Wiley in Advanced Materials Technologies
Wireless Modular Millirobots With Magnetic Actuation for Targeted Cardiac Drug Delivery
Infective endocarditis remains difficult to treat due to limited drug accumulation at infection sites via systemic delivery and reliance on invasive, high‐risk surgery. To address this, we present a wireless, modular millirobotic system actuated by external magnetic fields for targeted cardiac drug delivery. We validate the system in vitro using an agarose heart phantom under physiologically relevant pulsatile flow and ex vivo by demonstrating tissue penetration and module undocking in excised porcine heart tissue. The system comprises two cooperative millirobots: a barbed needle module that reduces tissue penetration force by 66.7% in cardiac tissue‐mimicking gels, and a drug module capable of delivering 22 microliter liquid doses over 180 min. AI‐assisted vision guidance enables autonomous navigation with root‐mean‐square tracking errors of 0.23 and 0.26 body lengths for the needle and drug modules, respectively. The modules support on‐demand magnetic docking and undocking, achieving success rates of 100% and 93%, respectively. These results highlight the potential of modular millirobots for precise, repeatable, and minimally invasive cardiac therapies.
- 28 September 2026
- Published by Wiley in Advanced Materials Technologies
Wireless Modular Millirobots With Magnetic Actuation for Targeted Cardiac Drug Delivery
Infective endocarditis remains difficult to treat due to limited drug accumulation at infection sites via systemic delivery and reliance on invasive, high‐risk surgery. To address this, we present a wireless, modular millirobotic system actuated by external magnetic fields for targeted cardiac drug delivery. We validate the system in vitro using an agarose heart phantom under physiologically relevant pulsatile flow and ex vivo by demonstrating tissue penetration and module undocking in excised porcine heart tissue. The system comprises two cooperative millirobots: a barbed needle module that reduces tissue penetration force by 66.7% in cardiac tissue‐mimicking gels, and a drug module capable of delivering 22 microliter liquid doses over 180 min. AI‐assisted vision guidance enables autonomous navigation with root‐mean‐square tracking errors of 0.23 and 0.26 body lengths for the needle and drug modules, respectively. The modules support on‐demand magnetic docking and undocking, achieving success rates of 100% and 93%, respectively. These results highlight the potential of modular millirobots for precise, repeatable, and minimally invasive cardiac therapies.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (5) , 5978-5985
Cosmos-Surg-DVRK: World Foundation Model-Based Automated Online Evaluation of Surgical Robot Policy Learning
The rise of robot-assisted surgery and vision-language-action models has accelerated progress in autonomous surgical policies and efficient assessment strategies. However, evaluating these policies directly on physical robotic platforms such as the da Vinci Research Kit (dVRK) remains hindered by high costs, time demands, reproducibility challenges, and variability in execution. World foundation models (WFM) for physical AI offer a transformative approach to simulate complex real-world surgical tasks, such as soft tissue deformation, with a high degree of realism. This work introduces Cosmos-Surg-dVRK, a surgical finetune of the Cosmos WFM, which, together with a trained video classifier, enables fully automated online evaluation and benchmarking of surgical policies. We evaluate Cosmos-Surg-dVRK using two independent, teleoperated, real-world dVRK surgical datasets. On tabletop suture pad tasks, the automated pipeline achieves strong correlation between online rollouts in Cosmos-Surg-dVRK and policy outcomes on the real dVRK Si platform, as well as good agreement between human labelers and the V-JEPA 2-derived video classifier. Additionally, preliminary experiments using the state-of-the-art SRT-H surgical policy for ex-vivo porcine cholecystectomy tasks demonstrate promising alignment between Cosmos-Surg-dVRK and real-world dVRK evaluations, highlighting the platform's potential for more complex surgical procedures.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (5) , 5978-5985
Cosmos-Surg-DVRK: World Foundation Model-Based Automated Online Evaluation of Surgical Robot Policy Learning
The rise of robot-assisted surgery and vision-language-action models has accelerated progress in autonomous surgical policies and efficient assessment strategies. However, evaluating these policies directly on physical robotic platforms such as the da Vinci Research Kit (dVRK) remains hindered by high costs, time demands, reproducibility challenges, and variability in execution. World foundation models (WFM) for physical AI offer a transformative approach to simulate complex real-world surgical tasks, such as soft tissue deformation, with a high degree of realism. This work introduces Cosmos-Surg-dVRK, a surgical finetune of the Cosmos WFM, which, together with a trained video classifier, enables fully automated online evaluation and benchmarking of surgical policies. We evaluate Cosmos-Surg-dVRK using two independent, teleoperated, real-world dVRK surgical datasets. On tabletop suture pad tasks, the automated pipeline achieves strong correlation between online rollouts in Cosmos-Surg-dVRK and policy outcomes on the real dVRK Si platform, as well as good agreement between human labelers and the V-JEPA 2-derived video classifier. Additionally, preliminary experiments using the state-of-the-art SRT-H surgical policy for ex-vivo porcine cholecystectomy tasks demonstrate promising alignment between Cosmos-Surg-dVRK and real-world dVRK evaluations, highlighting the platform's potential for more complex surgical procedures.
- Open Access
Fluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC
Magnetic actuation enables surgical robots to navigate complex anatomical pathways while reducing tissue trauma and improving surgical precision. However, clinical deployment is limited by the challenges of controlling such systems under fluoroscopic imaging, which provides low frame rate and noisy pose feedback. This paper presents a control framework that remains accurate and stable under such conditions by combining a nonlinear model predictive control (NMPC) framework that directly outputs coil currents, an analytically differentiable magnetic field model based on Zernike polynomials, and a Kalman filter to estimate the robot state. Experimental validation is conducted with two magnetic robots in a 3D-printed fluid workspace and a spine phantom replicating drug delivery in the epidural space. Results show the proposed control method remains highly accurate when feedback is downsampled to 3 Hz with added Gaussian noise (sigma = 2 mm), mimicking clinical fluoroscopy. In the spine phantom experiments, the proposed method successfully executed a drug delivery trajectory with a root mean square (RMS) position error of 1.18 mm while maintaining safe clearance from critical anatomical boundaries.
Open AccessFluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC
Magnetic actuation enables surgical robots to navigate complex anatomical pathways while reducing tissue trauma and improving surgical precision. However, clinical deployment is limited by the challenges of controlling such systems under fluoroscopic imaging, which provides low frame rate and noisy pose feedback. This paper presents a control framework that remains accurate and stable under such conditions by combining a nonlinear model predictive control (NMPC) framework that directly outputs coil currents, an analytically differentiable magnetic field model based on Zernike polynomials, and a Kalman filter to estimate the robot state. Experimental validation is conducted with two magnetic robots in a 3D-printed fluid workspace and a spine phantom replicating drug delivery in the epidural space. Results show the proposed control method remains highly accurate when feedback is downsampled to 3 Hz with added Gaussian noise (sigma = 2 mm), mimicking clinical fluoroscopy. In the spine phantom experiments, the proposed method successfully executed a drug delivery trajectory with a root mean square (RMS) position error of 1.18 mm while maintaining safe clearance from critical anatomical boundaries.
- 28 June 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
Accuracy Analysis and Enhancement via Transformer-based Robot Calibration of the da Vinci Research Kit Si (dVRK-Si)
Autonomous robotic surgery has the potential to achieve better patient outcomes and greater efficiency than manual approaches by leveraging precise robotic motion for task execution. Unlike articulated robots, tendon-driven surgical robots suffer from lower motion precision due to the hysteresis and friction inherent in their cable-pulley design. These nonlinear mechanical effects complicate precise end-effector control, posing challenges to autonomous task performance and safety concerns. In this paper, we present a calibration workflow using machine learning models to enhance the positioning accuracy of a tendon-driven surgical robot, evaluated on the real da Vinci Research Kit Si (dVRK-Si). An accuracy analysis was carried out for the dVRK-Si and a transformer-based model was trained to compensate for the nonlinear effects of the system, enhancing system positioning accuracy. The calibrated system was evaluated on trajectory-following tasks in Cartesian space, demonstrating 51.37% and 45.87% reduction in position and orientation errors. Additionally, we tested the models’ transferability with two uncalibrated surgical instruments and reported accuracy improvements over the first-generation dVRK-Classic.
- 28 June 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
Accuracy Analysis and Enhancement via Transformer-based Robot Calibration of the da Vinci Research Kit Si (dVRK-Si)
Autonomous robotic surgery has the potential to achieve better patient outcomes and greater efficiency than manual approaches by leveraging precise robotic motion for task execution. Unlike articulated robots, tendon-driven surgical robots suffer from lower motion precision due to the hysteresis and friction inherent in their cable-pulley design. These nonlinear mechanical effects complicate precise end-effector control, posing challenges to autonomous task performance and safety concerns. In this paper, we present a calibration workflow using machine learning models to enhance the positioning accuracy of a tendon-driven surgical robot, evaluated on the real da Vinci Research Kit Si (dVRK-Si). An accuracy analysis was carried out for the dVRK-Si and a transformer-based model was trained to compensate for the nonlinear effects of the system, enhancing system positioning accuracy. The calibrated system was evaluated on trajectory-following tasks in Cartesian space, demonstrating 51.37% and 45.87% reduction in position and orientation errors. Additionally, we tested the models’ transferability with two uncalibrated surgical instruments and reported accuracy improvements over the first-generation dVRK-Classic.
- 27 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
Mitigating Singularities in Control of Magnetic Capsule Endoscopes Using a Novel Nested Electromagnetic Coil System
Magnetic actuation systems that utilize external electromagnetic coils present a promising approach for controlling untethered small-scale robots, notably in medical applications. However, these systems frequently experience actuation singularities at which robotic control over the agent is lost or severely diminished. Such singularities may lead to excessively large current or rapid current changes that significantly affect the robots’ stability in specific areas of the workspace. In order to effectively mitigate these actuation singularities, this paper introduces a closed-loop control method using a novel nested electromagnetic coil system, leveraging finite element analysis-based magnetic field data and a novel controller combining a singularity solver and optimal current control method. The electromagnetic system has 12 coils nested in four coil units, each having three concentric coils with different outer radius, surrounding a central workspace. We call the 12-coil system Variable Outer Radius Individually Addressable Coil Stacks (VORIACS). Here, we experimentally evaluate the method for closed-loop trajectory tracking of a soft magnetic capsule endoscope (PillCam™) and a permanent magnet robot inside the VORIACS system at different magnetic field orientations. The results demonstrate that the VORIACS system with a singularity solver reduces root mean square (RMS) position tracking errors of the PillCam™by 46% to 50% and orientation tracking errors by 41% to 42% compared to a standard 4-coil system. Moreover, the system can achieve a notable 60.73% reduction in RMS position error, with sub-millimeter precision control when controlling the permanent magnet robot. We further manipulate the PillCam™for tracking a medical application-inspired complex trajectory, showcasing the system’s potential in precise control of magnetic devices for medical use.
- 27 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
Mitigating Singularities in Control of Magnetic Capsule Endoscopes Using a Novel Nested Electromagnetic Coil System
Magnetic actuation systems that utilize external electromagnetic coils present a promising approach for controlling untethered small-scale robots, notably in medical applications. However, these systems frequently experience actuation singularities at which robotic control over the agent is lost or severely diminished. Such singularities may lead to excessively large current or rapid current changes that significantly affect the robots’ stability in specific areas of the workspace. In order to effectively mitigate these actuation singularities, this paper introduces a closed-loop control method using a novel nested electromagnetic coil system, leveraging finite element analysis-based magnetic field data and a novel controller combining a singularity solver and optimal current control method. The electromagnetic system has 12 coils nested in four coil units, each having three concentric coils with different outer radius, surrounding a central workspace. We call the 12-coil system Variable Outer Radius Individually Addressable Coil Stacks (VORIACS). Here, we experimentally evaluate the method for closed-loop trajectory tracking of a soft magnetic capsule endoscope (PillCam™) and a permanent magnet robot inside the VORIACS system at different magnetic field orientations. The results demonstrate that the VORIACS system with a singularity solver reduces root mean square (RMS) position tracking errors of the PillCam™by 46% to 50% and orientation tracking errors by 41% to 42% compared to a standard 4-coil system. Moreover, the system can achieve a notable 60.73% reduction in RMS position error, with sub-millimeter precision control when controlling the permanent magnet robot. We further manipulate the PillCam™for tracking a medical application-inspired complex trajectory, showcasing the system’s potential in precise control of magnetic devices for medical use.
- 19 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (5) , 5438-5450
Flexible Accelerated-Wound-Healing Antibacterial Hydrogel-Nanofiber Scaffold for Intelligent Wearable Health Monitoring
Flexible epidermal sensors hold significant potential in personalized healthcare and multifunctional electronic skins. Nonetheless, achieving both robust sensing performance and efficient antibacterial protection, especially in medical paradigms involving electrophysiological signals for wound healing and intelligent health monitoring, remains a substantial challenge. Herein, we introduce a novel flexible accelerated-wound-healing biomaterial based on a hydrogel-nanofiber scaffold (HNFS) via electrostatic spinning and gel cross-linking. We effectively engineer a multifunctional tissue nanoengineered skin scaffold for wound treatment and health monitoring. Key features of HNFS include high tensile strength (24.06 MPa) and elasticity (214.67%), flexibility, biodegradability, and antibacterial properties, enabling assembly into versatile sensors for monitoring human motion and electrophysiological signals. Moreover, in vitro and in vivo experiments demonstrate that HNFS significantly enhances cell proliferation and skin wound healing, provide a comprehensive therapeutic strategy for smart sensing and tissue repair, and guide the development of high-performance "wound healing-health monitoring" bioelectronic skin scaffolds. Therefore, this study provides insights into crafting flexible and repairable skin sensors, holding potential for multifunctional health diagnostics and intelligent medical applications in intelligent wearable health monitoring and next-generation artificial skin fields.
- 19 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (5) , 5438-5450
Flexible Accelerated-Wound-Healing Antibacterial Hydrogel-Nanofiber Scaffold for Intelligent Wearable Health Monitoring
Flexible epidermal sensors hold significant potential in personalized healthcare and multifunctional electronic skins. Nonetheless, achieving both robust sensing performance and efficient antibacterial protection, especially in medical paradigms involving electrophysiological signals for wound healing and intelligent health monitoring, remains a substantial challenge. Herein, we introduce a novel flexible accelerated-wound-healing biomaterial based on a hydrogel-nanofiber scaffold (HNFS) via electrostatic spinning and gel cross-linking. We effectively engineer a multifunctional tissue nanoengineered skin scaffold for wound treatment and health monitoring. Key features of HNFS include high tensile strength (24.06 MPa) and elasticity (214.67%), flexibility, biodegradability, and antibacterial properties, enabling assembly into versatile sensors for monitoring human motion and electrophysiological signals. Moreover, in vitro and in vivo experiments demonstrate that HNFS significantly enhances cell proliferation and skin wound healing, provide a comprehensive therapeutic strategy for smart sensing and tissue repair, and guide the development of high-performance "wound healing-health monitoring" bioelectronic skin scaffolds. Therefore, this study provides insights into crafting flexible and repairable skin sensors, holding potential for multifunctional health diagnostics and intelligent medical applications in intelligent wearable health monitoring and next-generation artificial skin fields.
- Open Access
- 18 September 2021
- Published by Atlantis Press SARL
- p. 248-254
Digital Marketing Transition for Luxury Industry Under the New Coronavirus Epidemic - The Case of Burberry
- 18 September 2021
- Published by Atlantis Press SARL
- p. 248-254
Open AccessDigital Marketing Transition for Luxury Industry Under the New Coronavirus Epidemic - The Case of Burberry