MOMohammed Farhan Ojaimi

Mohammed Farhan Ojaimi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammed Farhan Ojaimi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bond Performance of the Slurry Infiltrated Fiber Concrete Overlay on Normal Strength Concrete Substrate

    by Mohammed F. Ojaimi, David A.M. Jawad, Abdullah A. Al-Hussein

    Many concrete structures require strengthening or repair and a significant method of strengthening the Reinforced Concrete (RC) members is to add a concrete jacket. A type of concrete known as Slurry-Infiltrated Fiber Concrete (SIFCON) has come into use. SIFCON is a unique form of Fiber-Reinforced Concrete (FRC) known for its superior mechanical properties. The effectiveness of upgrading the RC members through jacketing depends on several factors, the most important of which is the bond performance between the substrate and overlay layers. This study examined how various factors influence the bonding performance between the SIFCON overlay and the Normal Strength Concrete (NSC) substrate. The research investigated the effects of surface preparation methods, types of bonding agents, and steel fiber geometry. Three tests were conducted to evaluate the bond strength: the Slant Shear Test (SST), Tensile Bond Test (TBT), and Flexural Bond Test (FBT). The surface preparation methods ranked from best to worst as follows: Grinding (G), Sandblasting (S), and Diamond Cutting (DC). The increase in the bond strength depended on the type of bonding agent and the surface preparation method. When the failure mode changed from Bond Interface (BI) to both BI and Weaker Concrete (BI-WC) or from BI-WC to WC, the increase was noticeable. If the failure mode shifted directly from BI to WC, the growth was significant. However, if the failure mode remained the same, the increase was minimal.


  • Open Access

    Influence of Concrete Compressive Strength on CFRP Strengthening and Repairing of RC Two‐Way Slabs

    by Mohammed F. Ojaimi, Meyyada Y. Alabdulhady, Kadhim Z. Naser

    In this research, the feasibility of strengthening and repairing two‐way reinforced concrete slabs and the effect of compressive strength on the properties of strengthened and repaired slabs using CFRP sheets were studied. The experimental program includes testing twelve samples. Four samples served as control panels, while four samples were strengthened using CFRP sheets to study the effect of carbon sheets on the ultimate load capacity. Also, the four pretested control panels were also taken and rerepaired using CFRP sheets and retested for the purpose of evaluating their properties after repair. The ultimate load capacity, energy dissipation capacity, initial stiffness, and failure pattern were explained by the experimental results obtained. The experimental results revealed that the use of CFRP strips led to an improvement in the average ultimate loading capacity by 16.2% and 6.45% for the strengthening and repairing system, respectively. Also, the utilization of the CFRP strips as a strengthening system significantly improved the stiffness and the cracking load of RC two‐way slabs. It was also noted that the ultimate loading capacity was proportionally related to the concrete strength for strengthened slabs with an increase of 23.3% for slabs with the highest concrete strength (C: 70).


  • Open Access

    Shear and Flexural Behavior of Flat Slabs Casted with Polyolefin Fiber-Reinforced Concrete

    by Abdulnasser M. Abbas, Haleem K. Hussain, Mohammed Farhan Ojaimi

    This paper presents the influence of polyolefin fiber on the flexural and shear attitude on the flat slabs. Three slab sets (80 cm × 80 cm) were tested, each with a thickness of 10 cm. In the first set (S1), the effect of fiber content on the flexural behavior of the flat slab was considered. Therefore, four slab specimens were cast, one of which was considered as a control specimen with no fiber content, while the other three included fibers at 0.5, 1, and 1.5 percent of the total concrete volume. The second series of experiments studied the flexural behavior of flat slabs (S2) with an opening of 15 cm × 15 cm. The first specimen contained nil polyolefin, while the second included 1% polyolefin. In the third set (S3), consideration was taken for 0 and 1% of Polyolefin to realize the shear behavior of the flat slab. The increase in polyolefin fiber content from 0 to 1.5% (for slab set 1) will decrease the deflection from 4.5 mm to 2.3 mm, with an average of 3.58 mm, which is close to the deflection of a 1% polyolefin fiber specimen. Three dimensional models for the tested slabs were simulated numerically via ABAQUS software program. The ratio of the maximum deflection between the experimental and the numerical outcomes were varied with a range of 1.01 to 1.28, with an average of 1.14.


  • Open Access

    Fiber-Type Influence on the Flexural Behavior of RC Two-Way Slabs with an Opening

    by Haleem K. Hussain, Abdulnasser M. Abbas, Mohammed Farhan Ojaimi

    Combining fiber with concrete mixes has become essential and its widespread use improves the strength of structural concrete elements. This research conducted an experiment into the structural performance of flat slabs with and without a square opening using four types of fiber (hooked-end, straight, corrugated steel fiber and polyolefin fiber) to gain a better understanding of how the variance of fiber type and shape effects the flexural behaviors of two-way slabs. The test program involved (a) testing the properties of hardened concrete, such as compressive properties, modulus of rupture and splitting tensile strength, and (b) testing the flexural behavior of two-way slabs. Ten slabs were divided into five pairs, including two specimens used as reference specimens (with and without openings), and eight other specimens with different types of fibers. Results revealed that the existing fiber in concrete improved the mechanical properties of hardened concrete mix, and the compressive strength test showed higher improvement in specimens with hooked and straight steel fiber. The flexural behavior of reinforced concrete slab was significantly enhanced, and the flexural strength capacity was especially improved for the slabs strengthened with hooked-end and corrugated steel fiber. Polyolefin fiber showed a slight enhancement of mechanical properties and good improvement in flexural capacity. Generally, the highest increments in compressive strength and modulus of rupture were 24.8%, 20% and 11%, and the ultimate load-carrying capacity of slabs was 39%, 13% and 19% for specimens with steel hooked, steel corrugated and polyolefin fibers, respectively, compared with control specimens.


  • Open Access

    Destructive and nondestructive tests formulation for concrete containing polyolefin fibers

    by Ihab S. Saleh, Muthana Sh. Mahdi, Mohammed F. Ojaimi

    Polyolefin fiber is a new type of fiber that was used in concrete to improve some of the poor properties of concrete including; tensile strength, ductility, and fracture energy. In this research, the contribution of Polyolefin fiber in improving the properties of hardened concrete was examined by adding polyolefin fibers to mix with different fiber content. The polypropylene fibers were added as a ratio of 0.5, 0.75, 1.0, 1.5, and 2% of concrete volume. Destructive and non-destructive tests were carried out: slump, compression, splitting, and bending, Schmidt Hammer, and ultrasonic pulse velocity tests. The results showed that, as the polyolefin fiber content increases, the workability of concrete reduces dramatically. The experimental findings demonstrate that the concrete tensile strength and ductility were improved by a small improvement in overall compressive strength. The results show that the compressive strength increased gradually with the increase in fiber content of up to 1.5%, and then, the compressive strength starts to decrease. However, the tensile strength increases continuously with the fiber content increasing. A good relationship was obtained between the destructive and nondestructive tests.


  • Open Access

    Structural behavior of two-way slabs cast with different fiber types and contents

    by Mohammed Farhan Ojaimi, Malik K. Eb. Altaee, Nooralhuda Sami Aljabbri

    This paper presents an experimental investigation on the effects of incorporating Stainless-Steel Fibers (SSF) on the flexural behavior of reinforced concrete two-way slabs. For this deal, three types of steel fiber (straight, hooked, and corrugated steel fiber) are used. Each type of steel fiber was added in four different volume fractions. Each steel fiber shape was added separately by proportions (0, 0.5, 1, 1.5) % of the total concrete volume. Subsequently, ten 800 × 800 mm × 100 reinforced concrete slabs (three slabs for each type of fibers, one for each proportion, and the remaining one slab was the control) were cast and subjected to flexural tests. The effect of type and amount of SSF on flexural behavior of two-way slabs were studied. That, where 0.5% of steel fibers was added, the straight fibers were acknowledged in comparison to the others whereas the improvement to the stiffness was better and the ultimate load increased by 22.58%. At 1% of steel fibers, the ultimate load increased by (35, 43, and 29) % for straight, hooked, and corrugated fibers respectively which at this addition ratio the hooked fibers were the notable contributor as opposed to other types, and this observation was apparent in improving splitting and flexure strength for hardened concrete. Adding 1.5% of steel fibers to the concrete degrade the workability severely by (83-92)% for all types of steel fibers in parallel with little improvement on slabs behavior is contrary to 1% ratio, thus, the 1% is the recommended addition.