Chao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chao Li has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Junbo Deng
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
4 shared publications - Xulei Zhao
Xi'an Jiaotong University
3 shared publications Chao Huo
2 shared publicationsGuankun Zhao
2 shared publications- Jinghao Deng2 shared publications
- Mingjing Xu2 shared publications
Latest Publications
- Open Access
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Impact of Fast-Switching Fault Current Limiter on the Transient Recovery Voltage Characteristics of Circuit Breakers in 750 kV Power Systems
Excessive short-circuit current critically limits power grid development. The Fast-Switching Fault Current Limiter (FSFCL), a novel type of Inductive Fault Current Limiter (IFCL), can influence the Transient Recovery Voltage (TRV) characteristics across circuit breaker contacts during current interruption. This study refines the existing theoretical model of the TRV for circuit breakers by incorporating the impact of the oscillatory process in the contact voltage occurring between fault occurrence and circuit breaker interruption. The accuracy of the theoretical model was verified using a 750 kV system simulation model, while the impacts of the current-limiting inductance and parallel capacitance of both conventional IFCL and FSFCL on the TRV were investigated comparatively. The results reveal a non-monotonic relationship between the current-limiting inductance and both the TRV peak and Rate of Rise of Recovery Voltage (RRRV) in the FSFCL system, with multiple extremum points identified where these parameters are effectively mitigated to within standard specifications. Furthermore, the study shows that increasing the parallel capacitance reduces the RRRV. When the parallel capacitance exceeds 65 nF, the RRRV in the FSFCL system becomes lower than that in the conventional IFCL system. When the parallel capacitance exceeds 70 nF, the RRRV can be reduced to below 2 kV/μs.
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessImpact of Fast-Switching Fault Current Limiter on the Transient Recovery Voltage Characteristics of Circuit Breakers in 750 kV Power Systems
Excessive short-circuit current critically limits power grid development. The Fast-Switching Fault Current Limiter (FSFCL), a novel type of Inductive Fault Current Limiter (IFCL), can influence the Transient Recovery Voltage (TRV) characteristics across circuit breaker contacts during current interruption. This study refines the existing theoretical model of the TRV for circuit breakers by incorporating the impact of the oscillatory process in the contact voltage occurring between fault occurrence and circuit breaker interruption. The accuracy of the theoretical model was verified using a 750 kV system simulation model, while the impacts of the current-limiting inductance and parallel capacitance of both conventional IFCL and FSFCL on the TRV were investigated comparatively. The results reveal a non-monotonic relationship between the current-limiting inductance and both the TRV peak and Rate of Rise of Recovery Voltage (RRRV) in the FSFCL system, with multiple extremum points identified where these parameters are effectively mitigated to within standard specifications. Furthermore, the study shows that increasing the parallel capacitance reduces the RRRV. When the parallel capacitance exceeds 65 nF, the RRRV in the FSFCL system becomes lower than that in the conventional IFCL system. When the parallel capacitance exceeds 70 nF, the RRRV can be reduced to below 2 kV/μs.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Subsynchronous Stability Analysis of DFIG-Based Wind Farm Considering the Error of Current Measuring System
Although many scholars have made a comprehensive explanation of the mechanism of subsynchronous oscillation (SSO), there still exist unexplained events in actual wind farms. Therefore, from the perspective of input signal of current controller, this article proposes an equivalent model of doubly fed induction generators (DFIGs) connected to series-compensated transmission line that considers the influence of the current measuring system. The mathematical model of the current measuring system is established by a$\Gamma $ -type circuit and a$\pi $ -type circuit equivalent to the electromagnetic current transformer and the power cable, respectively. Then, the oscillation mechanism of DFIGs in critical stability is explained from the perspective of Nyquist criterion. Meanwhile, the impact regulations of the proposed current measuring system on the SSO occurrence in wind farm are verified by PSCAD and compared with field tests. Finally, the transfer characteristics of the proposed model are explored within a wide frequency range, illustrating the necessity to consider the current measuring system when analyzing the stability of SSO.- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Subsynchronous Stability Analysis of DFIG-Based Wind Farm Considering the Error of Current Measuring System
Although many scholars have made a comprehensive explanation of the mechanism of subsynchronous oscillation (SSO), there still exist unexplained events in actual wind farms. Therefore, from the perspective of input signal of current controller, this article proposes an equivalent model of doubly fed induction generators (DFIGs) connected to series-compensated transmission line that considers the influence of the current measuring system. The mathematical model of the current measuring system is established by a$\Gamma $ -type circuit and a$\pi $ -type circuit equivalent to the electromagnetic current transformer and the power cable, respectively. Then, the oscillation mechanism of DFIGs in critical stability is explained from the perspective of Nyquist criterion. Meanwhile, the impact regulations of the proposed current measuring system on the SSO occurrence in wind farm are verified by PSCAD and compared with field tests. Finally, the transfer characteristics of the proposed model are explored within a wide frequency range, illustrating the necessity to consider the current measuring system when analyzing the stability of SSO.- 25 July 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 249
Transient electric field analysis of 750 kV GIS breaker under lightning impulse delivery test
- 25 July 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 249
Transient electric field analysis of 750 kV GIS breaker under lightning impulse delivery test
- 16 May 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 247
Suppressing the Zero-missing phenomenon in 330 kV long cable transmission system equipped with shunt reactors
- 16 May 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 247
Suppressing the Zero-missing phenomenon in 330 kV long cable transmission system equipped with shunt reactors
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1583-1592
Nonlinear Traits of Leakage Current and Dynamic Actions of Surface Discharges on Ice-Covered Insulators Under DC Voltages
In order to improve the technology for predicting flashover risks of ice-covered insulators, this paper delves into the nonlinear characteristics of leakage current (LC) and the phase changes of arcing discharges. The dynamic relationship between them is analyzed quantitatively. The DC ice flashover experiment is conducted in the CIGELE artificial climate room. The dynamic characteristics of arcs during the DC ice flashover process were studied. The chaos of the LC time series is examined by estimating the maximum Lyapunov exponent ( L max ) using embedded space theory and the phase space reconstruction method. An analysis of the dynamic behavior of LC is conducted using recurrent plot (RP) technology, leading to the development of an index to quantify the regularity of the LC . A quantitative analysis of the cooperative relationship between the LC and arc length, as extracted through image processing, is performed, confirming the regular patterns of LC variation. The findings indicate that variations in the LC and arc length are effective in distinguishing between the three stages of ice flashover. L max exceeds zero at all stages, indicating the chaotic nature of the LC, which is most pronounced during the early phase of the second stage. RP technology provides a clear, dynamic visualization of icing insulator discharge behavior through graphic texture transformation. The nonlinear indexes, RR and DET, of LC demonstrate an increase alongside the development of arc discharge, indicating a growth of the regular and deterministic components of the discharge. Additionally, there is a synchronous increase in the LC and arc length, with a clear correlation exhibited during the four arc extension periods (T1-T4). As the flashover approaches, the degree of fitting between them increases significantly.
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1583-1592
Nonlinear Traits of Leakage Current and Dynamic Actions of Surface Discharges on Ice-Covered Insulators Under DC Voltages
In order to improve the technology for predicting flashover risks of ice-covered insulators, this paper delves into the nonlinear characteristics of leakage current (LC) and the phase changes of arcing discharges. The dynamic relationship between them is analyzed quantitatively. The DC ice flashover experiment is conducted in the CIGELE artificial climate room. The dynamic characteristics of arcs during the DC ice flashover process were studied. The chaos of the LC time series is examined by estimating the maximum Lyapunov exponent ( L max ) using embedded space theory and the phase space reconstruction method. An analysis of the dynamic behavior of LC is conducted using recurrent plot (RP) technology, leading to the development of an index to quantify the regularity of the LC . A quantitative analysis of the cooperative relationship between the LC and arc length, as extracted through image processing, is performed, confirming the regular patterns of LC variation. The findings indicate that variations in the LC and arc length are effective in distinguishing between the three stages of ice flashover. L max exceeds zero at all stages, indicating the chaotic nature of the LC, which is most pronounced during the early phase of the second stage. RP technology provides a clear, dynamic visualization of icing insulator discharge behavior through graphic texture transformation. The nonlinear indexes, RR and DET, of LC demonstrate an increase alongside the development of arc discharge, indicating a growth of the regular and deterministic components of the discharge. Additionally, there is a synchronous increase in the LC and arc length, with a clear correlation exhibited during the four arc extension periods (T1-T4). As the flashover approaches, the degree of fitting between them increases significantly.