Sherif M. El-Sayed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sherif M. El-Sayed has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Asmaa Moustafa
Department of Nuclear Medicine and Oncology, Faculty of Medicine, Ain Shams University, Cairo, Egypt
1 shared publication - Dina M. Abdelaziz
Radiotherapy Department, Baheya Hospital, Giza, Egypt
1 shared publication - Ehab Marouf Attalla
Medical Physics Department, National Cancer Institute, Cairo University, Cairo, Egypt
1 shared publication Ibrahim Hassan
Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt
1 shared publication- Mohamed Mahmoud Fathy
Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
1 shared publication - Reem H. El-Gebaly
Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
1 shared publication
Latest Publications
- 6 July 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (3) , 423-431
Stereotactic body radiation therapy for prostate cancer: a dosimetric comparison of IMRT and VMAT using flattening filter and flattening filter-free beams
This retrospective study was performed to evaluate plan quality and treatment delivery parameters of stereotactic body radiation therapy (SBRT) for prostate cancer. The study utilized different isocentric modulated techniques: intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using 6 MV flattening filter (FF) and 10 MV flattening filter-free beams (FFF). Fifteen retrospective prostate cancer patients were selected for this study. Sixty plans were created with an SBRT-prescribed dose of 36.25 Gy delivered in five fractions. Planning target volume (PTV) coverage, plan quality indices, doses delivered to organs at risk (OARs), and treatment delivery parameters were compared for all plans. It turned out that VMAT plans, particularly those using the FFF beam, provided superior target conformality and a steeper dose gradient as compared to IMRT plans. Additionally, VMAT plans showed better OARs sparing compared to IMRT plans. However, IMRT plans delivered a lower maximum dose to the target than VMAT plans. Importantly, the VMAT plans resulted in reduced treatment delivery parameters, including beam on time (BOT), monitor unit (MU), and modulation factor (MF), compared to IMRT plans. Furthermore, a statistically significant difference was observed in BOT and mean body dose between FF and FFF beams, with FFF beams showing superior performance. Considering all results, VMAT using 10 MV (FFF) is suggested for treating prostate cancer patients with SBRT. This offers the fastest delivery in addition to maintaining the highest plan quality.
- 6 July 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (3) , 423-431
Stereotactic body radiation therapy for prostate cancer: a dosimetric comparison of IMRT and VMAT using flattening filter and flattening filter-free beams
This retrospective study was performed to evaluate plan quality and treatment delivery parameters of stereotactic body radiation therapy (SBRT) for prostate cancer. The study utilized different isocentric modulated techniques: intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using 6 MV flattening filter (FF) and 10 MV flattening filter-free beams (FFF). Fifteen retrospective prostate cancer patients were selected for this study. Sixty plans were created with an SBRT-prescribed dose of 36.25 Gy delivered in five fractions. Planning target volume (PTV) coverage, plan quality indices, doses delivered to organs at risk (OARs), and treatment delivery parameters were compared for all plans. It turned out that VMAT plans, particularly those using the FFF beam, provided superior target conformality and a steeper dose gradient as compared to IMRT plans. Additionally, VMAT plans showed better OARs sparing compared to IMRT plans. However, IMRT plans delivered a lower maximum dose to the target than VMAT plans. Importantly, the VMAT plans resulted in reduced treatment delivery parameters, including beam on time (BOT), monitor unit (MU), and modulation factor (MF), compared to IMRT plans. Furthermore, a statistically significant difference was observed in BOT and mean body dose between FF and FFF beams, with FFF beams showing superior performance. Considering all results, VMAT using 10 MV (FFF) is suggested for treating prostate cancer patients with SBRT. This offers the fastest delivery in addition to maintaining the highest plan quality.
- Open Access
- 1 February 2023
- Published by Egyptian Knowledge Bank in Egyptian Journal of Biomedical Engineering and Biophysics
- Vol. 24 (1) , 13-30
Physical and Radiobiological Evaluation of Patient Setup Errors in the Radiotherapy Procedure for Prostate Cancer
Radiobiological and dosimetric indices related effects of patient setup errors were evaluated for prostate patients treated using volumetric modulated arc therapy technique. Materials and Methods: Ten patients were treated and evaluated during the course of treatment. Each one was treated with 2 Gy for 39 fractions. The setup verification of each patient was determined using an electronic portal imaging device for 5 fractions during the treatment course. The mean of setup errors for those 5 fractions was calculated for each patient. Dose-Volume Histograms of the planning target volume, femoral heads, bladder and rectum were generated, and the conformity index, homogeneity index, tumor control probability, and normal tissue complication probability were determined.The population random set-up errors were (3.61), (3.24), and (3.87) mm in vertical, longitudinal, and lateral directions respectively. Radiobiological indexes were evaluated witht and without inrtoduction of the random errors. In the original plan the average EUD in the VMAT plans was 77.59 Gy, and the average of TCP was 98.24%; but with the introduction of the errors, the average EUD became in the order of 60.24 Gy, while the average of TCP was in the order of 84.24%. Significant differences were observed between the two plans. The dosimetric and biological impacts were evaluated and indicated that setup errors during VMAT treatments can lead to a non-significant change of conformity and homogeneity but can lead to changes in the dose distribution influencing the target volume coverage and altering the deliver dose to the organs at risk.
- 1 February 2023
- Published by Egyptian Knowledge Bank in Egyptian Journal of Biomedical Engineering and Biophysics
- Vol. 24 (1) , 13-30
Open AccessPhysical and Radiobiological Evaluation of Patient Setup Errors in the Radiotherapy Procedure for Prostate Cancer
Radiobiological and dosimetric indices related effects of patient setup errors were evaluated for prostate patients treated using volumetric modulated arc therapy technique. Materials and Methods: Ten patients were treated and evaluated during the course of treatment. Each one was treated with 2 Gy for 39 fractions. The setup verification of each patient was determined using an electronic portal imaging device for 5 fractions during the treatment course. The mean of setup errors for those 5 fractions was calculated for each patient. Dose-Volume Histograms of the planning target volume, femoral heads, bladder and rectum were generated, and the conformity index, homogeneity index, tumor control probability, and normal tissue complication probability were determined.The population random set-up errors were (3.61), (3.24), and (3.87) mm in vertical, longitudinal, and lateral directions respectively. Radiobiological indexes were evaluated witht and without inrtoduction of the random errors. In the original plan the average EUD in the VMAT plans was 77.59 Gy, and the average of TCP was 98.24%; but with the introduction of the errors, the average EUD became in the order of 60.24 Gy, while the average of TCP was in the order of 84.24%. Significant differences were observed between the two plans. The dosimetric and biological impacts were evaluated and indicated that setup errors during VMAT treatments can lead to a non-significant change of conformity and homogeneity but can lead to changes in the dose distribution influencing the target volume coverage and altering the deliver dose to the organs at risk.