Zitao Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zitao Zhao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Lin Wen
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
3 shared publications - Bingkai Liu
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
2 shared publications - Jie Feng
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
2 shared publications - Qi Guo
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
2 shared publications - Yudong Li
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
2 shared publications - Baolong Chen
Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 13 April 2026
- Published by American Astronomical Society in The Astronomical Journal
- Vol. 171 (5) , 283
Radiation-induced Degradation and On-orbit Performance Assessment of an sCMOS Detector
Optical astronomical projects have traditionally relied on charge-coupled device (CCD) detectors. However, next-generation complementary metal-oxide-semiconductor (CMOS) technology, with advantages including high-speed readout, low dark current, and electronic shutter capability, is reshaping observational strategies and substantially improving observing efficiency. Many ground-based facilities are now transitioning from CCDs to scientific CMOS (sCMOS) detectors, yet the long-term radiation-induced performance degradation of sCMOS devices in space environments has not been systematically characterized. In this work, we irradiate a GSENSE1081BSI sCMOS detector under representative on-orbit operating conditions, including vacuum and low temperature, and continuously monitor its performance during both the irradiation and subsequent annealing phases. Based on the measured evolution of key detector parameters, we predict the corresponding on-orbit degradation of photometric signal-to-noise ratio. The predicted performance meets the requirements of the microlensing telescope of the forthcoming Earth 2.0 mission, demonstrating the suitability of this detector for space-based time-domain observations and for potential application in future space missions. Our results further provide quantitative benchmarks and practical guidance for ground-based radiation testing of sCMOS detectors and for assessing their long-term performance evolution in space.
- 13 April 2026
- Published by American Astronomical Society in The Astronomical Journal
- Vol. 171 (5) , 283
Open AccessRadiation-induced Degradation and On-orbit Performance Assessment of an sCMOS Detector
Optical astronomical projects have traditionally relied on charge-coupled device (CCD) detectors. However, next-generation complementary metal-oxide-semiconductor (CMOS) technology, with advantages including high-speed readout, low dark current, and electronic shutter capability, is reshaping observational strategies and substantially improving observing efficiency. Many ground-based facilities are now transitioning from CCDs to scientific CMOS (sCMOS) detectors, yet the long-term radiation-induced performance degradation of sCMOS devices in space environments has not been systematically characterized. In this work, we irradiate a GSENSE1081BSI sCMOS detector under representative on-orbit operating conditions, including vacuum and low temperature, and continuously monitor its performance during both the irradiation and subsequent annealing phases. Based on the measured evolution of key detector parameters, we predict the corresponding on-orbit degradation of photometric signal-to-noise ratio. The predicted performance meets the requirements of the microlensing telescope of the forthcoming Earth 2.0 mission, demonstrating the suitability of this detector for space-based time-domain observations and for potential application in future space missions. Our results further provide quantitative benchmarks and practical guidance for ground-based radiation testing of sCMOS detectors and for assessing their long-term performance evolution in space.
- Open Access
- 1 October 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (10)
Total ionization dose and electromagnetic pulse synergistic effects on low dropout linear regulator
As a power management chip widely used in various electronic systems, the low dropout regulator (LDO) plays a crucial role in the normal operation of electronic systems. Ionizing radiation and electromagnetic pulse (EMP) radiation can cause interference and damage to the LDO, posing risks to the proper functioning of electronic systems in large-scale scientific devices. In this study, through separate experimental investigations on the Total Ionizing Dose (TID) effects, EMP effects, and synergistic effect of the LDO, it was found that parameters such as the LDO output voltage decreases with increasing irradiation dose, with more severe degradation observed under grounded bias. The EMP effects mainly cause oscillations in the LDO output voltage and a slight increase in its mean value. The results of the synergistic effect experiments indicate that there is a certain synergistic interaction between the TID effects and the EMP effects. The synergistic effects lead to an increase in the amplitude of the oscillations and changes in the mean value of the output voltage.
- 1 October 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (10)
Open AccessTotal ionization dose and electromagnetic pulse synergistic effects on low dropout linear regulator
As a power management chip widely used in various electronic systems, the low dropout regulator (LDO) plays a crucial role in the normal operation of electronic systems. Ionizing radiation and electromagnetic pulse (EMP) radiation can cause interference and damage to the LDO, posing risks to the proper functioning of electronic systems in large-scale scientific devices. In this study, through separate experimental investigations on the Total Ionizing Dose (TID) effects, EMP effects, and synergistic effect of the LDO, it was found that parameters such as the LDO output voltage decreases with increasing irradiation dose, with more severe degradation observed under grounded bias. The EMP effects mainly cause oscillations in the LDO output voltage and a slight increase in its mean value. The results of the synergistic effect experiments indicate that there is a certain synergistic interaction between the TID effects and the EMP effects. The synergistic effects lead to an increase in the amplitude of the oscillations and changes in the mean value of the output voltage.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (10) , 2242-2251
Mechanisms of Dark Current Increase and Pixel Anomalies Induced by 2-GeV Ta-Irradiation in 8T-CMOS Image Sensors
The space optoelectronic imaging systems are susceptible to the impact of high-energy particle irradiation during on-orbit operations, leading to dark current increase and various types of pixel anomalies, which degrades device performance. Heavy ion and proton irradiation experiments on 8T-CMOS image sensors are conducted to investigate the characteristics of dark current distributions and hot pixels. Additionally, cold pixels are observed in 8T-image sensors. The results demonstrate that dark current increases with increasing fluence, coupled with SRIM simulations, Coulombic elastic scattering can be identified as the main cause for dark current increases due to proton and heavy ion irradiations, the value of scattering cross-sections may ultimately lead to offsets in the universal damage factor. A common exponential behavior is observed, integrating heavy ions into the existing theoretical framework, temperature dependence and annealing of exponential behavior are also discussed. Both hot pixels and cold pixels can be attributed to defects induced by particle irradiation, with the difference that the defects causing hot pixels are located near the pinned photodiode, while the defects causing cold pixels are located in a specific capacitance of the 8T-CMOS image sensor.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (10) , 2242-2251
Mechanisms of Dark Current Increase and Pixel Anomalies Induced by 2-GeV Ta-Irradiation in 8T-CMOS Image Sensors
The space optoelectronic imaging systems are susceptible to the impact of high-energy particle irradiation during on-orbit operations, leading to dark current increase and various types of pixel anomalies, which degrades device performance. Heavy ion and proton irradiation experiments on 8T-CMOS image sensors are conducted to investigate the characteristics of dark current distributions and hot pixels. Additionally, cold pixels are observed in 8T-image sensors. The results demonstrate that dark current increases with increasing fluence, coupled with SRIM simulations, Coulombic elastic scattering can be identified as the main cause for dark current increases due to proton and heavy ion irradiations, the value of scattering cross-sections may ultimately lead to offsets in the universal damage factor. A common exponential behavior is observed, integrating heavy ions into the existing theoretical framework, temperature dependence and annealing of exponential behavior are also discussed. Both hot pixels and cold pixels can be attributed to defects induced by particle irradiation, with the difference that the defects causing hot pixels are located near the pinned photodiode, while the defects causing cold pixels are located in a specific capacitance of the 8T-CMOS image sensor.