Xu Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xu Tian has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Niclas Roxhed
Department of Intelligent Systems, KTH Royal Institute of Technology, Stockholm, Sweden
4 shared publications Göran Stemme
Department of Micro and Nanosystems, School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, Stockholm 100 44, Sweden
3 shared publicationsHanie Kavand
2 shared publications- Joachim Oberhammer
KTH Royal Institute of Technology
2 shared publications Martin Köhler
2 shared publicationsPer-Olof Berggren
2 shared publications
Latest Publications
- Open Access
Microscopic Neuromodulation with Locally Enhanced Electric Field
Implantable neural stimulation devices play an important role in fundamental neuroscience research, clinical applications, and emerging technologies such as neuroprosthetics and brain–machine interfaces, with increasing demand for spatially precise neuromodulation at cellular and circuit levels. Microelectrode-based electrical stimulation relies on charge injection into neural tissue, where irreversible electrochemical reactions at the electrode–electrolyte interface may lead to electrode degradation and tissue damage. Although microscale magnetic stimulation provides an alternative, it typically requires sophisticated microcoil architectures and complex fabrication processes. In this work, we introduce a novel neural stimulation mechanism based on localized electric field enhancement. The proposed device employs an electrically insulated sharp metallic tip to concentrate the electric field and generate localized displacement currents capable of activating nearby neurons. Finite element simulations were performed to investigate the underlying stimulation mechanism and establish design guidelines for device fabrication. MEMS-based neural probes were subsequently fabricated and experimentally evaluated through in vivo animal studies, with neuronal activation observed at distances of less than 200 µm from the probe tip using two-photon imaging. By avoiding Faradaic charge transfer at the tissue interface while offering high spatial localization, orientation selectivity, and a compact device architecture, the proposed approach provides a promising alternative to existing stimulation technologies for chronic and high-density neural interfaces.
Open AccessMicroscopic Neuromodulation with Locally Enhanced Electric Field
Implantable neural stimulation devices play an important role in fundamental neuroscience research, clinical applications, and emerging technologies such as neuroprosthetics and brain–machine interfaces, with increasing demand for spatially precise neuromodulation at cellular and circuit levels. Microelectrode-based electrical stimulation relies on charge injection into neural tissue, where irreversible electrochemical reactions at the electrode–electrolyte interface may lead to electrode degradation and tissue damage. Although microscale magnetic stimulation provides an alternative, it typically requires sophisticated microcoil architectures and complex fabrication processes. In this work, we introduce a novel neural stimulation mechanism based on localized electric field enhancement. The proposed device employs an electrically insulated sharp metallic tip to concentrate the electric field and generate localized displacement currents capable of activating nearby neurons. Finite element simulations were performed to investigate the underlying stimulation mechanism and establish design guidelines for device fabrication. MEMS-based neural probes were subsequently fabricated and experimentally evaluated through in vivo animal studies, with neuronal activation observed at distances of less than 200 µm from the probe tip using two-photon imaging. By avoiding Faradaic charge transfer at the tissue interface while offering high spatial localization, orientation selectivity, and a compact device architecture, the proposed approach provides a promising alternative to existing stimulation technologies for chronic and high-density neural interfaces.
- Open Access
- 4 November 2026
- Published by Elsevier in Microelectronic Engineering
- Vol. 308
Metallization-induced residual stress control in large-span SOI MEMS structures for sub-terahertz waveguide switching
- 4 November 2026
- Published by Elsevier in Microelectronic Engineering
- Vol. 308
Open AccessMetallization-induced residual stress control in large-span SOI MEMS structures for sub-terahertz waveguide switching
- Open Access
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (8) , 1956-1966
Comparative Study of DRIE-Based Fabrication Strategies for Silicon-Micromachined Subterahertz Waveguide Components
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (8) , 1956-1966
Open AccessComparative Study of DRIE-Based Fabrication Strategies for Silicon-Micromachined Subterahertz Waveguide Components
- Open Access
MEMS-Based Ultrasonic Energy Harvesting Platform Enabling Sustained In Vivo Operation of Implantable Microdevices
Implantable microdevices capable of autonomous operation over extended lifetimes are promising enablers for minimally invasive diagnostics and therapy. Microelectromechanical systems (MEMS)-based piezoelectric ultrasonic energy harvesters (PUEH) have emerged as a compelling approach for powering implantable microdevices, where both miniaturization and efficient wireless energy transfer are essential. Here, we present a highly miniaturized (5 × 5 × 5 mm³) ultrasonic energy-harvesting platform enabling sustained in vivo operation of implantable microdevices. The platform integrates a MEMS-PUEH, a high-efficiency power management system, an energy storage element, and representative functional electronics. We first investigate the effect of backside cavity boundary conditions on MEMS-PUEH performance and show that a sealed air-filled chamber significantly outperforms an open water-filled cavity, yielding a 46% increase in root-mean-square output voltage and a 117% increase in average output power across a 2 kΩ resistive load under identical incident acoustic intensity at the respective optimal operating frequencies. We then demonstrate system-level integration and characterization. In a tissue-mimicking phantom, under an incident acoustic intensity of approximately 257 mW/cm 2 , the device charges an 11.5 mF supercapacitor, a 5 µAh solid-state microbattery, and a 100 µF capacitor to their nominal voltages in less than 5 min, 3 min, and 20 s, respectively. Finally, in vivo validation demonstrates fully autonomous operation of representative functional electronics following ultrasonic charging of the onboard energy storage element. These results establish a highly miniaturized and fully integrated ultrasonic energy-harvesting platform that advances MEMS-based power solutions for implantable biomedical microdevices.
Open AccessMEMS-Based Ultrasonic Energy Harvesting Platform Enabling Sustained In Vivo Operation of Implantable Microdevices
Implantable microdevices capable of autonomous operation over extended lifetimes are promising enablers for minimally invasive diagnostics and therapy. Microelectromechanical systems (MEMS)-based piezoelectric ultrasonic energy harvesters (PUEH) have emerged as a compelling approach for powering implantable microdevices, where both miniaturization and efficient wireless energy transfer are essential. Here, we present a highly miniaturized (5 × 5 × 5 mm³) ultrasonic energy-harvesting platform enabling sustained in vivo operation of implantable microdevices. The platform integrates a MEMS-PUEH, a high-efficiency power management system, an energy storage element, and representative functional electronics. We first investigate the effect of backside cavity boundary conditions on MEMS-PUEH performance and show that a sealed air-filled chamber significantly outperforms an open water-filled cavity, yielding a 46% increase in root-mean-square output voltage and a 117% increase in average output power across a 2 kΩ resistive load under identical incident acoustic intensity at the respective optimal operating frequencies. We then demonstrate system-level integration and characterization. In a tissue-mimicking phantom, under an incident acoustic intensity of approximately 257 mW/cm 2 , the device charges an 11.5 mF supercapacitor, a 5 µAh solid-state microbattery, and a 100 µF capacitor to their nominal voltages in less than 5 min, 3 min, and 20 s, respectively. Finally, in vivo validation demonstrates fully autonomous operation of representative functional electronics following ultrasonic charging of the onboard energy storage element. These results establish a highly miniaturized and fully integrated ultrasonic energy-harvesting platform that advances MEMS-based power solutions for implantable biomedical microdevices.
- Open Access
Millimeter-scale implantable device for continuous in vivo tracking of tumor growth via fluorescence sensing
- Open Access
- 12 November 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-14
Integrated microoptical system for continuous fluorescence monitoring of microtissues
Microphysiological systems (MPS) are advanced in vitro platforms engineered to replicate in vivo conditions for studying human biology, disease mechanisms, and drug responses with greater physiological relevance. Fluorescence sensing is widely used as a functional readout in MPS due to its high sensitivity, selectivity, and stability. However, conventional fluorescence sensing systems often rely on bulky instrumentation with limited integration, which restricts continuous in situ monitoring, scalable high-throughput analysis, and spatially resolved investigation in multi-organ-on-a-chip models. To address these limitations, we present a highly miniaturized, fully integrated optical system with a 1 mm² footprint, enabling continuous in situ fluorescence monitoring of three-dimensional microtissues in close proximity. The system integrates microscale illumination and sensing units for fluorescence excitation and selective detection, an optical element for guided light propagation, and a microcage for mechanical confinement of microtissues. To demonstrate its capabilities, we integrated the miniaturized optical system with an MPS-relevant platform to monitor fluorescence signals in transgenic mouse pancreatic islets expressing genetically encoded calcium indicators. The integrated platform enables real-time, continuous monitoring of islet responses to potassium chloride stimulation and tracking of calcium oscillations for over two hours, providing valuable information about the functional status of the pancreatic islets. Our work enhances the analytical capabilities of MPS through the integration of miniaturized on-chip quantitative assessment tools, enabling precise, in situ, and continuous monitoring of biological activities in close proximity.
- 12 November 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-14
Open AccessIntegrated microoptical system for continuous fluorescence monitoring of microtissues
Microphysiological systems (MPS) are advanced in vitro platforms engineered to replicate in vivo conditions for studying human biology, disease mechanisms, and drug responses with greater physiological relevance. Fluorescence sensing is widely used as a functional readout in MPS due to its high sensitivity, selectivity, and stability. However, conventional fluorescence sensing systems often rely on bulky instrumentation with limited integration, which restricts continuous in situ monitoring, scalable high-throughput analysis, and spatially resolved investigation in multi-organ-on-a-chip models. To address these limitations, we present a highly miniaturized, fully integrated optical system with a 1 mm² footprint, enabling continuous in situ fluorescence monitoring of three-dimensional microtissues in close proximity. The system integrates microscale illumination and sensing units for fluorescence excitation and selective detection, an optical element for guided light propagation, and a microcage for mechanical confinement of microtissues. To demonstrate its capabilities, we integrated the miniaturized optical system with an MPS-relevant platform to monitor fluorescence signals in transgenic mouse pancreatic islets expressing genetically encoded calcium indicators. The integrated platform enables real-time, continuous monitoring of islet responses to potassium chloride stimulation and tracking of calcium oscillations for over two hours, providing valuable information about the functional status of the pancreatic islets. Our work enhances the analytical capabilities of MPS through the integration of miniaturized on-chip quantitative assessment tools, enabling precise, in situ, and continuous monitoring of biological activities in close proximity.
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (5) , 524-531
Low-Temperature Fabrication of Millimeter-Scale MEMS-Based Piezoelectric Ultrasonic Energy Harvesters for Medical Implants
MEMS-based piezoelectric ultrasonic energy harvesters (PUEH) have become one of the most promising options for replacing or transferring energy to batteries in medical implants, where device miniaturization and power optimization are needed. Among the most commonly used piezoelectric materials in PUEH, lead zirconate titanate (PZT) is widely acknowledged for its excellent piezoelectric properties, good stability, and low cost. However, the performance of PZT degrades when the processing temperature approaches and exceeds half of its Curie temperature (T $_{\mathrm{c}})$ , limiting its application. Here, we demonstrate a highly miniaturized, low-temperature fabricated MEMS-based PUEH with an effective ultrasound harvesting area of 0.79 mm $^{2}$ and an effective device volume of 0.35 mm $^{3}$ . The low-temperature adhesive epoxy bonding ensures the temperature throughout the entire fabrication process remains below 85 $^{\circ}$ C, which preserves the properties of the integrated piezoelectric material to the greatest extent. This allows the use of bulk PZT-5H, a material that possesses superior piezoelectric properties, but has a relatively low T $_{\mathrm{c,}}$ to enhance device performance. Our device outputs a root-mean-square (RMS) voltage of 0.62 V and an RMS power of 0.19 mW on a 2 k $\Omega $ resistive load at an optimum operating frequency of 200 kHz, with a reception distance of 20 mm in water and input acoustic power intensity of 178 mW/cm $^{2}$ . The proposed design and fabrication technique enable our device to achieve the smallest effective size among the reported MEMS-based PUEH while still being capable of powering up numerous implantable medical devices and being compatible with various commercially available power management units. 2024-0081
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (5) , 524-531
Low-Temperature Fabrication of Millimeter-Scale MEMS-Based Piezoelectric Ultrasonic Energy Harvesters for Medical Implants
MEMS-based piezoelectric ultrasonic energy harvesters (PUEH) have become one of the most promising options for replacing or transferring energy to batteries in medical implants, where device miniaturization and power optimization are needed. Among the most commonly used piezoelectric materials in PUEH, lead zirconate titanate (PZT) is widely acknowledged for its excellent piezoelectric properties, good stability, and low cost. However, the performance of PZT degrades when the processing temperature approaches and exceeds half of its Curie temperature (T $_{\mathrm{c}})$ , limiting its application. Here, we demonstrate a highly miniaturized, low-temperature fabricated MEMS-based PUEH with an effective ultrasound harvesting area of 0.79 mm $^{2}$ and an effective device volume of 0.35 mm $^{3}$ . The low-temperature adhesive epoxy bonding ensures the temperature throughout the entire fabrication process remains below 85 $^{\circ}$ C, which preserves the properties of the integrated piezoelectric material to the greatest extent. This allows the use of bulk PZT-5H, a material that possesses superior piezoelectric properties, but has a relatively low T $_{\mathrm{c,}}$ to enhance device performance. Our device outputs a root-mean-square (RMS) voltage of 0.62 V and an RMS power of 0.19 mW on a 2 k $\Omega $ resistive load at an optimum operating frequency of 200 kHz, with a reception distance of 20 mm in water and input acoustic power intensity of 178 mW/cm $^{2}$ . The proposed design and fabrication technique enable our device to achieve the smallest effective size among the reported MEMS-based PUEH while still being capable of powering up numerous implantable medical devices and being compatible with various commercially available power management units. 2024-0081