YZYongming Zhang

Yongming Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yongming Zhang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems

    by Lingqi Su, Yongming Zhang, Shanshou Li

    Fifth-generation district heating and cooling (5GDHC) systems have attracted increasing attention because they can supply heating and cooling simultaneously, enable buildings to act as thermal prosumers, and facilitate the recovery of low-grade waste heat. Because these networks operate near ambient temperature, their temperature can be modulated over a relatively wide range in both winter and summer, creating the potential to use the pipe network for both heat and cold storage. However, the economic value of using this inherent thermal capacity and the benefit of increasing it through pipe enlargement remain unclear. This study develops a dynamic thermo-hydraulic optimization framework that represents bidirectional flow, water and ground thermal states, temperature-dependent heat-pump and chiller performance, pumping electricity, and annualized system costs. A genetic algorithm is used offline to compare daily-constant and predictive network-temperature control at three pipe-capacity levels in a synthetic 5GDHC system developed using Beijing weather and tariff data. Predictive control reduced the annualized cost at all three pipe-capacity levels, with savings ranging from 0.17% to 0.52%. Reductions in monthly demand charges and active-equipment capacity costs provided most of the economic benefit, whereas the energy charge changed only slightly or increased. Increasing every pipe by one or two catalog sizes raised the network water volume by 32.1% and 69.5% and reduced pumping electricity by 51.8% and 74.0%, but increased the annualized cost by 0.14% and 0.44%, respectively. The results show that the thermal capacity already available in a 5GDHC network can provide modest operational flexibility, but enlarging pipes solely to obtain additional thermal storage did not show a substantial economic advantage in the investigated case.

  • Open Access

    A Novel Energy-Based Crack Resistance Assessment Method for Steel Fiber-Reinforced Lightweight Aggregate Concrete via Partially Restrained Ring Tests

    by Binbin Zhang, Yongming Zhang, Wenbao Wang

    Early-age cracking limits the structural use of steel fiber-reinforced lightweight aggregate concrete (SFLWAC), and robust experimental evaluation methods are still needed. This study examines the influence of steel fiber volume fractions (i.e., 0%, 0.5%, 1.0%, and 2.0%) on the cracking performance of SFLWAC through mechanical testing, autogenous shrinkage measurements, and two types of partially restrained ring tests, with and without a clapboard. The performance of three crack resistance indices is compared: the strain-based ASTM C1581 index, a stress-based area index, and a newly proposed energy-based index defined as the strain energy accumulation degree (SEAD), i.e., the ratio between the accumulated and critical strain energy density. The 28-day splitting tensile strength was improved by 77.9% and autogenous shrinkage was diminished by 30.7% as steel fiber volume content increased from 0 to 2.0%, thereby improving the resistance to shrinkage-induced cracking. In the partially restrained ring tests, SEAD decreased with increasing fiber content, and crack initiation occurred when SEAD reached an approximately constant threshold, whereas ASTM C1581 and the area index could not consistently rank mixtures when some rings cracked and others remained intact. These results demonstrate that SEAD provides a physically meaningful and unified measure of cracking risk for SFLWAC under partially restrained shrinkage and has the potential to be extended to other fiber-reinforced concretes and shrinkage-related cracking problems.

  • Open Access

    A Multi-Objective Optimized Approach to Photovoltaic-Battery Systems Constrained by Transformer Capacity for Existing Buildings

    by Jiesheng Yu, Yongming Zhang, Zhe Yan, Lie Chen, Weidong Fu

    As urban populations grow and energy demands escalate, it is increasingly challenging for existing building electrical infrastructure in densely populated areas to meet contemporary energy requirements. Traditional grid expansion methods often impose prohibitive economic costs and environmental impacts. Photovoltaic-battery (PVB) systems emerge as a sustainable alternative to enhance building energy self-sufficiency while addressing transformer capacity constraints. This study develops a multi-objective optimization methodology for PVB system configuration in retrofit applications, introducing the transmission limit ratio (TLR) metric to quantify grid interaction capacity. Taking a residential building as a case study, the constraints on configuration variables under insufficient transformer capacity are obtained through simulation. Applying the NSGA-II algorithm, optimal configurations are identified for economic and environmental scenarios. In terms of configuration, a PVB system, 0.743 PV penetration, 205 kWh battery is the best optimal configuration for an economic operation scenario, while 1.356 PV penetration and 201 kWh battery is the best for an environmental operation scenario, when the TLR is 0.8. The analysis demonstrates PV penetration’s critical role in scenario transition, while battery capacity primarily ensures system stability across TLR variations. This methodology provides practical insights for engineers in optimizing sustainable energy systems within existing infrastructure constraints, particularly relevant for high-density urban environments.


  • Open Access

    A Novel AI-Driven Multi-objective Optimization Approach for Energy System Design in Industrial Zone

    by Jiesheng Yu, Yongming Zhang, Zhe Yan, Ziqi Li

    In the context of global energy conservation and emission reduction, it is imperative to improve energy efficiency and promote sustainable development. The industry sector has consistently been a pivotal industry in implementing low-carbon practices, particularly in large industrial zones characterized by high energy consumption and carbon emissions. A focal point of research in such contexts revolves around the configuration of energy systems in industrial zone. This paper proposes a novel AI-driven multi-objective optimization approach for energy system design in industrial zone. Economy, environmental sustainability, and safety are considered as optimization objectives, and the Pareto front solution set is calculated using the NSGA-II algorithm. The optimal system design is determined based on the composite optimization objective function under different priority scenarios. This method provides valuable insights that could serve as a blueprint for energy system design in industrial zones, offering guidance towards more efficient and environmentally conscious energy configurations.

  • An allocative method of stationary and vehicle‐mounted mobile energy storage for emergency power supply in urban areas

    by Zhe Yan, Yongming Zhang, Jiesheng Yu

    Extreme climate events are on the rise, posing significant challenges to power systems, leading to blackouts and infrastructure damage. Energy storage plays a crucial role in enhancing grid resilience by providing stability, backup power, load shifting capabilities, and voltage regulation. While stationary energy storage has been widely adopted, there is growing interest in vehicle‐mounted mobile energy storage due to its mobility and flexibility. This article proposes an integrated approach that combines stationary and vehicle‐mounted mobile energy storage to optimize power system safety and stability under the conditions of limiting the total investment in both types of energy storages. The principal aim is to minimize the weighted energy not served index in the presence of fault conditions. By strategically allocating energy storage resources and dynamically dispatching stored energy, operators can ensure rapid response and effective power restoration, improving overall reliability in the face of extreme weather events.


  • Open Access

    Integrated Energy Planning for Near-Zero Carbon Emission Demonstration District in Urban Areas: A Case Study of Meishan District in Ningbo, China

    by Xiaoyan Xu, Ying Wang, Yingjun Ruan, Jian Wang, Kailiang Ge, Yongming Zhang, Haikui Jin

    Reasonable regional integrated energy planning is an important prerequisite for the construction of a Near-Zero Carbon Emission Demonstration District (NCEDD). An integrated energy planning scheme that is based on a three-step planning method with the objective of achieving an NCEDD is proposed in this paper. First, the planning objectives should be determined. After that, the planning strategies should be established. Finally, the planning approaches should be proposed according to the previously determined objectives and strategies. A case study considering the integrated energy planning of the Meishan International Near-Zero Carbon Emission Demonstration District (MINCEDD) is investigated to explain the planning method. In addition, the planning results, which are indicated as indexes, are explained, analyzed, and compared to the ones of other districts. The indexes include a proportion of renewable energy to primary energy (73% by 2030 and 108% by 2050), a proportion of renewable power to total power consumption (98% by 2030 and 111% by 2050), and CO2 emission reduction rates (70% by 2030 and 100% by 2050) and are more advanced than other districts in China. This planning scheme and method can provide a reference for the integrated energy planning of NCEDDs in developed urban areas.


  • Open Access

    A Novel Reconstruction Approach to Elevator Energy Conservation Based on a DC Micro-Grid in High-Rise Buildings

    by Yongming Zhang, Zhe Yan, Feng Yuan, Jiawei Yao, Bao Ding

    Elevators were reported to cause an important part of building energy consumption. In general, each elevator has two operation states: The load state and power regeneration state. During operation, it has the potential to save energy by using regeneration power efficiently. In existing research, a set of energy storage devices are installed for every elevator, which is highly costly. In this paper, an energy conservation approach for elevators based on a direct current (DC) micro-grid is proposed, which has better economy. Then, an innovative energy-efficient device for the elevator group is designed based on a supercapacitor with similar characteristics and lifetimes. In a high-rise building case study, the experimental test and field data collection show that the innovative approach could result in a high energy efficiency within 15.87–23.1% and 24.1–54.5%, respectively. It is expected that the proposed method and designed device could be employed practically, saving energy consumption for elevator reconstruction.


  • Open Access

    A Group Approach of Smart Hybrid Poles with Renewable Energy, Street Lighting and EV Charging Based on DC Micro-Grid

    by Jiawei Yao, Yongming Zhang, Zhe Yan, Li Li

    Energy crisis and environmental pollution have become global problems, and the increasing use of energy has caused climate change. Electric vehicle (EV) is regarded as the future of the automotive industry, because of the lesser impact on the environment than traditional vehicles. In recent years, electric vehicles have developed rapidly. However, the development of charging points and service cannot adapt to the development trend of EV. In urban areas, the distribution characteristics of street lighting and charging points are similar. Therefore, the street lighting pole with EV charging is proposed. However, due to the capacity limit of public grid, the single hybrid pole is only suitable for slow charging. This paper proposes hybrid poles group based on renewable energy, street lighting, and EV charging, which can realize fast charging and slow charging based on DC micro-grid with help of energy storage device. For studying the suitable number in a group of smart hybrid pole, the efficiency model of smart hybrid poles group is proposed. The efficiency model indicates that the group approach has better performance than the single pole, which provides a theoretical basis for practical construction.


  • Open Access

    A Hybrid Building Power Distribution System in Consideration of Supply and Demand-Side: A Short Overview and a Case Study

    by Yongming Zhang, Zhe Yan, Li Li, Jiawei Yao

    As the quantity of direct current (DC) load and wireless power transmission (WPT) devices are continuously increasing in building, in order to efficiently utilize renewable energy (which outputs DC power) such as photovoltaic (PV), especially for building integrated photovoltaic (BIPV), and regeneration energy from elevators (which also outputs DC power), a novel building power distribution system architecture is explored in consideration of the characteristics of supply and demand-side in this paper. The proposed architecture is a hybrid framework integrated with conventional alternating current (AC) power distribution system, DC power distribution and WPT system. The applied AC and DC hybrid power distribution system has higher conversion efficiency than a single AC power system, which indicates that the former is becoming an important trend of building power distribution. In addition, the results of experimental test in a case study suggest that the proposed architecture can provide fine service for efficient application of renewable energy and regeneration energy in building. The obtained results also can serve as a foundation to promote the development of building power distribution system and related practical application in building.