Sahar Ranjbar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sahar Ranjbar has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Pennazio
Istituto Nazionale di Fisica Nucleare Sezione di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10125, Italy
4 shared publications - Piergiorgio Cerello
Istituto Nazionale di Fisica Nucleare Sezione di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10125, Italy
4 shared publications - Veronica Ferrero
Universita degli Studi di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10124, Italy
4 shared publications - Diango M. Montalvan Olivares
Università degli Studi di Torino, Via Pietro Giuria 1, Torino, Piemonte, 10125, Italy
3 shared publications - Elisa Fiorina
INFN Sezione di Torino, Torino, Italy
3 shared publications - Julius Werner
Universität zu Lübeck
3 shared publications
Latest Publications
- Open Access
- 12 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Prompt gamma timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly sensitive to beam energy and target density, which, under controlled detector positioning, enables real-time monitoring of particle range, detection of morphological changes, and support for adaptive treatment strategies. Objective: This study investigates for the first time the application of PGT in carbon ion therapy. Approach: Measurements were performed using a dedicated detection system composed of a silicon strip sensor for primary ion timing and a LaBr3(Ce) scintillator read out by a SiPM matrix for secondary radiation. Carbon ion beams with energies of 166.41, 268.86, and 398.84 MeV/u irradiated a homogeneous 30.0 cm PMMA target at CNAO (Pavia, Italy). The secondary radiation detector was positioned at four off-beam positions to assess the robustness of the PGT technique. Monte Carlo simulations based on Geant4 were conducted for all configurations to evaluate agreement and predictive capability. Main Results: A quantitative bin-by-bin comparison of experimental and simulated PGT intensities demonstrated strong agreement within the 95% confidence interval, with no incompatible bins at 166.41 MeV/u, at most 1% at 268.86 MeV/u, and up to 8% at 398.84 MeV/u, depending on detector position. Prompt gammas were identified as the dominant contribution to the detected signals, particularly for detector positions upstream with respect to the primary particle beam, minimizing signal contamination from neutrons and charged fragments. Significance: The validated experimental - simulation framework confirms the capability of the proposed PGT system to resolve energy-dependent differences and highlights its potential for detecting clinically relevant changes in the particle beam range, supporting further development toward real-time monitoring in carbon ion therapy.
- 12 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Open AccessPrompt gamma timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly sensitive to beam energy and target density, which, under controlled detector positioning, enables real-time monitoring of particle range, detection of morphological changes, and support for adaptive treatment strategies. Objective: This study investigates for the first time the application of PGT in carbon ion therapy. Approach: Measurements were performed using a dedicated detection system composed of a silicon strip sensor for primary ion timing and a LaBr3(Ce) scintillator read out by a SiPM matrix for secondary radiation. Carbon ion beams with energies of 166.41, 268.86, and 398.84 MeV/u irradiated a homogeneous 30.0 cm PMMA target at CNAO (Pavia, Italy). The secondary radiation detector was positioned at four off-beam positions to assess the robustness of the PGT technique. Monte Carlo simulations based on Geant4 were conducted for all configurations to evaluate agreement and predictive capability. Main Results: A quantitative bin-by-bin comparison of experimental and simulated PGT intensities demonstrated strong agreement within the 95% confidence interval, with no incompatible bins at 166.41 MeV/u, at most 1% at 268.86 MeV/u, and up to 8% at 398.84 MeV/u, depending on detector position. Prompt gammas were identified as the dominant contribution to the detected signals, particularly for detector positions upstream with respect to the primary particle beam, minimizing signal contamination from neutrons and charged fragments. Significance: The validated experimental - simulation framework confirms the capability of the proposed PGT system to resolve energy-dependent differences and highlights its potential for detecting clinically relevant changes in the particle beam range, supporting further development toward real-time monitoring in carbon ion therapy.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (1) , 137-143
Performance Analysis of In-Beam PET Range Verification System for Carbon Ion Beams
The Superconducting Ion Gantry (SIG) project aims to develop a reliable in vivo Range Verification System (RVS) for integration into a multi-ion gantry. The project includes researching, designing, and testing the system’s fundamental components. Based on RVS element performance, the ultimate goal is to design a full system that meets clinical requirements. Therefore, in this study, we present the performance evaluation of a small in-beam Positron Emission Tomography (PET) prototype for carbon ion irradiations. The experimental setup consists of 6 PET modules arranged in hexagonal geometry (3 vs 3 partial ring configuration), with a radius of 98 mm. Each detector block features 16×16 pixels, 3.2 mm pitch of segmented Lutetium Fine Silicate (LFS) scintillator crystals, coupled one-to-one to Silicon Photomultiplier (SiPM) matrices. Homogeneous phantoms were irradiated with two monoenergetic beams at different energies at CNAO (Italian National Center of Oncological Hadron Therapy). Data were acquired online during the irradiation. For this study, images are reconstructed from the irradiation in the pauses between beam spills (inter-spill). The performance analysis was focused on evaluating the stability of range difference estimation considering different subsets of coincidence events along the beam irradiation.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (1) , 137-143
Performance Analysis of In-Beam PET Range Verification System for Carbon Ion Beams
The Superconducting Ion Gantry (SIG) project aims to develop a reliable in vivo Range Verification System (RVS) for integration into a multi-ion gantry. The project includes researching, designing, and testing the system’s fundamental components. Based on RVS element performance, the ultimate goal is to design a full system that meets clinical requirements. Therefore, in this study, we present the performance evaluation of a small in-beam Positron Emission Tomography (PET) prototype for carbon ion irradiations. The experimental setup consists of 6 PET modules arranged in hexagonal geometry (3 vs 3 partial ring configuration), with a radius of 98 mm. Each detector block features 16×16 pixels, 3.2 mm pitch of segmented Lutetium Fine Silicate (LFS) scintillator crystals, coupled one-to-one to Silicon Photomultiplier (SiPM) matrices. Homogeneous phantoms were irradiated with two monoenergetic beams at different energies at CNAO (Italian National Center of Oncological Hadron Therapy). Data were acquired online during the irradiation. For this study, images are reconstructed from the irradiation in the pauses between beam spills (inter-spill). The performance analysis was focused on evaluating the stability of range difference estimation considering different subsets of coincidence events along the beam irradiation.
- Open Access
- 3 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
A novel detector for 4D tracking in particle therapy
- 3 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
Open AccessA novel detector for 4D tracking in particle therapy
- Open Access
- 15 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (14) , 14NT02
Stopping power and range estimations in proton therapy based on prompt gamma timing: motion models and automated parameter optimization
Objective. Particle therapy treatments are currently limited by uncertainties of the delivered dose. Verification techniques like Prompt-Gamma-Timing-based Stopping Power Estimation (PGT-SPE) may allow for reduction of safety margins in treatment planning. Approach. From Prompt-Gamma-Timing measurements, we reconstruct the spatiotemporal distribution of prompt gamma emissions, which is linked to the average motion of the primary particles. The stopping power is determined by fitting a model of the average particle motion. Here, we compare a previously published implementation of the particle motion model with an alternative formulation and present two formulations to automatically select the hyperparameters of our procedure. The performance was assessed using Monte-Carlo simulations of proton beams (60 MeV–219 MeV) impinging on a homogeneous PMMA phantom. Main results. The range was successfully determined within a standard deviation of 3 mm for proton beam energies from 70 MeV to 219 MeV. Stopping power estimates showed errors below 5% for beam energies above 160 MeV. At lower energies, the estimation performance degraded to unsatisfactory levels due to the short range of the protons. The new motion model improved the estimation performance by up to 5% for beam energies from 100 MeV to 150 MeV with mean errors ranging from 6% to 18%. The automated hyperparameter optimization matched the average error of previously reported manual selections, while significantly reducing the outliers. Significance. The data-driven hyperparameter optimization allowed for a reproducible and fast evaluation of our method. The updated motion model and evaluation at new beam energies bring us closer to applying PGT-SPE in more complex scenarios. Direct comparison of stopping power estimates between treatment planning and measurements during irradiation would offer a more direct verification than other secondary-particle-based techniques.
- 15 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (14) , 14NT02
Open AccessStopping power and range estimations in proton therapy based on prompt gamma timing: motion models and automated parameter optimization
Objective. Particle therapy treatments are currently limited by uncertainties of the delivered dose. Verification techniques like Prompt-Gamma-Timing-based Stopping Power Estimation (PGT-SPE) may allow for reduction of safety margins in treatment planning. Approach. From Prompt-Gamma-Timing measurements, we reconstruct the spatiotemporal distribution of prompt gamma emissions, which is linked to the average motion of the primary particles. The stopping power is determined by fitting a model of the average particle motion. Here, we compare a previously published implementation of the particle motion model with an alternative formulation and present two formulations to automatically select the hyperparameters of our procedure. The performance was assessed using Monte-Carlo simulations of proton beams (60 MeV–219 MeV) impinging on a homogeneous PMMA phantom. Main results. The range was successfully determined within a standard deviation of 3 mm for proton beam energies from 70 MeV to 219 MeV. Stopping power estimates showed errors below 5% for beam energies above 160 MeV. At lower energies, the estimation performance degraded to unsatisfactory levels due to the short range of the protons. The new motion model improved the estimation performance by up to 5% for beam energies from 100 MeV to 150 MeV with mean errors ranging from 6% to 18%. The automated hyperparameter optimization matched the average error of previously reported manual selections, while significantly reducing the outliers. Significance. The data-driven hyperparameter optimization allowed for a reproducible and fast evaluation of our method. The updated motion model and evaluation at new beam energies bring us closer to applying PGT-SPE in more complex scenarios. Direct comparison of stopping power estimates between treatment planning and measurements during irradiation would offer a more direct verification than other secondary-particle-based techniques.