Chunbo Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chunbo Han has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xueping Xu
Beihang University
10 shared publications - Yi Liu
Department of Thoracic Surgery and Institute of Thoracic Oncology West China Hospital, Sichuan University Chengdu China
9 shared publications - Xuefeng Zhang
Beihang University
3 shared publications - Xin Sun
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
2 shared publications Xuefeng Zhang
1 shared publicationYi Liu
1 shared publication
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 7503906
Reverse Design of Cylindrical Uniform Magnetic Field Coils Based on Target Field Method and Its Optical Path Integration Optimization
Uniform field coils are a key factor influencing the performance and integration of SERF atomic magnetometers. To balance the requirements for high uniformity and the provision of an optical path within structural constraints, this study proposes a design method based on the target field method (TFM). This method is tailored for cylindrical radial uniform field coils and supports the integration of a central optical aperture. This method employs a Fourier series expansion to describe the surface current density on a predefined cylindrical geometry, establishes an inverse solution model by combining it with the target magnetic field distribution, and introduces Tikhonov regularization to overcome ill-posed issues during the solution process. Unlike conventional applications, this method incorporates a piecewise current density model and a central exclusion zone parameter z0. This allows for the flexible definition of current-free regions in the central area of the coil, thereby natively integrating the optical detection pathway. Using a cylindrical coil with a radius of 20 mm and a height of 50 mm as an example, two types of radial field-flattening coils were designed and fabricated: one without a central aperture and the other with a 5 mm optical aperture. Experimental results indicate that the coil without a central aperture achieved a volume fraction of 84.42% where magnetic field inhomogeneity within the target spherical region was better than 10-4, validating the effectiveness of this method in enhancing magnetic field uniformity. The design incorporating the optical aperture successfully maintained optical functionality whilst retaining relatively high uniformity. This study provides a highly reliable coil design scheme for miniaturized atomic magnetometers intended for wearable magnetoencephalography, balancing magnetic field performance with optical path integration.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 7503906
Reverse Design of Cylindrical Uniform Magnetic Field Coils Based on Target Field Method and Its Optical Path Integration Optimization
Uniform field coils are a key factor influencing the performance and integration of SERF atomic magnetometers. To balance the requirements for high uniformity and the provision of an optical path within structural constraints, this study proposes a design method based on the target field method (TFM). This method is tailored for cylindrical radial uniform field coils and supports the integration of a central optical aperture. This method employs a Fourier series expansion to describe the surface current density on a predefined cylindrical geometry, establishes an inverse solution model by combining it with the target magnetic field distribution, and introduces Tikhonov regularization to overcome ill-posed issues during the solution process. Unlike conventional applications, this method incorporates a piecewise current density model and a central exclusion zone parameter z0. This allows for the flexible definition of current-free regions in the central area of the coil, thereby natively integrating the optical detection pathway. Using a cylindrical coil with a radius of 20 mm and a height of 50 mm as an example, two types of radial field-flattening coils were designed and fabricated: one without a central aperture and the other with a 5 mm optical aperture. Experimental results indicate that the coil without a central aperture achieved a volume fraction of 84.42% where magnetic field inhomogeneity within the target spherical region was better than 10-4, validating the effectiveness of this method in enhancing magnetic field uniformity. The design incorporating the optical aperture successfully maintained optical functionality whilst retaining relatively high uniformity. This study provides a highly reliable coil design scheme for miniaturized atomic magnetometers intended for wearable magnetoencephalography, balancing magnetic field performance with optical path integration.
- 6 September 2026
- Published by Elsevier in Measurement
- Vol. 291
Design method for three-dimensional non-uniform magnetic field compensation coils in magnetic shielding room based on harmonic polynomials
- 6 September 2026
- Published by Elsevier in Measurement
- Vol. 291
Design method for three-dimensional non-uniform magnetic field compensation coils in magnetic shielding room based on harmonic polynomials
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Polynomial Fitting-Based Design Method for Nonuniform Dynamic Magnetic Field Compensation Coils
Magnetic shielding is the key technology to create a near-zero magnetic environment. Nevertheless, the inherent characteristics of passive magnetic shielding result in a residual field that is generally nonuniform and highly vulnerable to interference by environmental magnetic fields. To achieve a stable, low-remanence near-zero magnetic environment, this study proposes a design method for magnetic compensation coils capable of dynamically compensating nonuniform residual fields in the magnetic shielded room (MSR). A polynomial is defined for fitting the residual field distribution. Applying the principle of shared symmetry, the polynomial terms are grouped, leading to the design of a nonuniform magnetic compensation coil system comprising five biplanar coils. Simulations and experiments show that the proposed coils can achieve effective compensation of irregular nonuniform magnetic field distributions through adjustment of the applied current and have effective dynamic compensation performance for alternating magnetic fields within the [1, 0.01] Hz frequency band. Compared with a compensation approach relying solely on the superposition of uniform and gradient field, the proposed nonuniform coils system exhibits superior adaptability to the irregular magnetic fields. This work provides a method for the design of single-axis dynamic nonuniform magnetic compensation coils and further establishes a scalable framework for three-axis nonuniform magnetic compensation.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Polynomial Fitting-Based Design Method for Nonuniform Dynamic Magnetic Field Compensation Coils
Magnetic shielding is the key technology to create a near-zero magnetic environment. Nevertheless, the inherent characteristics of passive magnetic shielding result in a residual field that is generally nonuniform and highly vulnerable to interference by environmental magnetic fields. To achieve a stable, low-remanence near-zero magnetic environment, this study proposes a design method for magnetic compensation coils capable of dynamically compensating nonuniform residual fields in the magnetic shielded room (MSR). A polynomial is defined for fitting the residual field distribution. Applying the principle of shared symmetry, the polynomial terms are grouped, leading to the design of a nonuniform magnetic compensation coil system comprising five biplanar coils. Simulations and experiments show that the proposed coils can achieve effective compensation of irregular nonuniform magnetic field distributions through adjustment of the applied current and have effective dynamic compensation performance for alternating magnetic fields within the [1, 0.01] Hz frequency band. Compared with a compensation approach relying solely on the superposition of uniform and gradient field, the proposed nonuniform coils system exhibits superior adaptability to the irregular magnetic fields. This work provides a method for the design of single-axis dynamic nonuniform magnetic compensation coils and further establishes a scalable framework for three-axis nonuniform magnetic compensation.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
A Study of 3-D Magnetic Field Regulation Method With Dynamically Variable Multichannel Orthogonal Array Coils
To solve the problems of the traditional magnetic shielding cylinders compensation coil system, such as complex structure, large volume, and insufficient flexibility of magnetic field (MF) adjustment, this study proposes a design method of d single-layer dynamically variable multi-channel orthogonal array coils (DVM-OAC) in a spindle-shaped magnetic shielding cylinders (sMSC). It uses an array of orthogonal crossed wires on a single-layer curved grid (R and A direction). Through multi-channel independent control and dynamic current regulation, the DVM-OAC achieves precise generation and real-time compensation of three-axis (x, y, and z) uniform MF. Compared with the traditional structure of three independent Helmholtz coils stacked on top of each other, the DVM-OAC integrates the three-axis function in a single physical space, which reduces the volume by about 21.46%. The percentage of the space where the uniformity of the DVM-OAC is less than 3% reaches 3.98%, which is much larger than that of the three-axis Helmholtz coils, which is 0.82%. Experiments indicate that DVM-OAC can ensure high triaxial MF uniformity in the center region of sMSC, which is consistent with the theoretical results. This technology provides a new idea for high-precision magnetic environment regulation, which is especially suitable for wearable devices, implantable medical devices and other scenarios with stringent requirements for lightweighting and flexibility.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
A Study of 3-D Magnetic Field Regulation Method With Dynamically Variable Multichannel Orthogonal Array Coils
To solve the problems of the traditional magnetic shielding cylinders compensation coil system, such as complex structure, large volume, and insufficient flexibility of magnetic field (MF) adjustment, this study proposes a design method of d single-layer dynamically variable multi-channel orthogonal array coils (DVM-OAC) in a spindle-shaped magnetic shielding cylinders (sMSC). It uses an array of orthogonal crossed wires on a single-layer curved grid (R and A direction). Through multi-channel independent control and dynamic current regulation, the DVM-OAC achieves precise generation and real-time compensation of three-axis (x, y, and z) uniform MF. Compared with the traditional structure of three independent Helmholtz coils stacked on top of each other, the DVM-OAC integrates the three-axis function in a single physical space, which reduces the volume by about 21.46%. The percentage of the space where the uniformity of the DVM-OAC is less than 3% reaches 3.98%, which is much larger than that of the three-axis Helmholtz coils, which is 0.82%. Experiments indicate that DVM-OAC can ensure high triaxial MF uniformity in the center region of sMSC, which is consistent with the theoretical results. This technology provides a new idea for high-precision magnetic environment regulation, which is especially suitable for wearable devices, implantable medical devices and other scenarios with stringent requirements for lightweighting and flexibility.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (3) , 3823-3832
Active–Passive Coupling Analysis and Optimal Design of Internal and External Hybrid Coils in MSC
To enhance the performance of ultra-weak magnetic measurement equipment, an optimal design method for the internal and external hybrid coil (IEHC) by the improved target field method (TFM) is proposed. Firstly, an analytical model of the active-passive coupling between the magnetically shielded cylinder (MSC) and the magnetic field (MF) distribution of the IEHC is developed. Then, the established analytical model is combined with TFM to devise the coils inside and outside the MSC. Moreover, the design parameters are optimal with the differential squirrel search algorithm (DSSA). Simulations demonstrate that in large target regions, the maximum MF deviation of IEHC decreases from 38.89% (DC-IEHC) to 21.09%, representing a 45.77% improvement. In small target regions, the deviation drops from 38.89% to 3.56%, a reduction of 90.85%. Experimental validation confirms the effectiveness of the method, providing theoretical support for optimizing active magnetic compensation coils in ultra-weak magnetic measurement systems.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (3) , 3823-3832
Active–Passive Coupling Analysis and Optimal Design of Internal and External Hybrid Coils in MSC
To enhance the performance of ultra-weak magnetic measurement equipment, an optimal design method for the internal and external hybrid coil (IEHC) by the improved target field method (TFM) is proposed. Firstly, an analytical model of the active-passive coupling between the magnetically shielded cylinder (MSC) and the magnetic field (MF) distribution of the IEHC is developed. Then, the established analytical model is combined with TFM to devise the coils inside and outside the MSC. Moreover, the design parameters are optimal with the differential squirrel search algorithm (DSSA). Simulations demonstrate that in large target regions, the maximum MF deviation of IEHC decreases from 38.89% (DC-IEHC) to 21.09%, representing a 45.77% improvement. In small target regions, the deviation drops from 38.89% to 3.56%, a reduction of 90.85%. Experimental validation confirms the effectiveness of the method, providing theoretical support for optimizing active magnetic compensation coils in ultra-weak magnetic measurement systems.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Design Method of a Novel Helmet-Shaped Wearable Self-Shielding Coil
To satisfy the development of portable and miniaturized extremely weak magnetic measuring devices, a novel helmet-shaped wearable self-shielding coil (HWSC) design method is proposed in this article. An analytical calculation model of HWSC is established by the boundary element method (BEM) which achieves the optimum design of self-shielding coils with a high homogeneous magnetic field (MF). Weighting coefficients are introduced to precisely control the selection of target field points. The calculated maximum MF deviation inside the HWSC and maximum MF attenuation deviation outside are 2.28% and 16.08%, respectively, which reduces the external MF attenuation by 69.15% compared with the coil without considering coupling. The experimental results show that the maximum internal deviation and external attenuation deviation of HWSC are 2.86% and 17.84%, respectively. This approach provides new ideas for the optimal design of internal coils in the development of magnetically shielded devices toward miniaturization and portability.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Design Method of a Novel Helmet-Shaped Wearable Self-Shielding Coil
To satisfy the development of portable and miniaturized extremely weak magnetic measuring devices, a novel helmet-shaped wearable self-shielding coil (HWSC) design method is proposed in this article. An analytical calculation model of HWSC is established by the boundary element method (BEM) which achieves the optimum design of self-shielding coils with a high homogeneous magnetic field (MF). Weighting coefficients are introduced to precisely control the selection of target field points. The calculated maximum MF deviation inside the HWSC and maximum MF attenuation deviation outside are 2.28% and 16.08%, respectively, which reduces the external MF attenuation by 69.15% compared with the coil without considering coupling. The experimental results show that the maximum internal deviation and external attenuation deviation of HWSC are 2.86% and 17.84%, respectively. This approach provides new ideas for the optimal design of internal coils in the development of magnetically shielded devices toward miniaturization and portability.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14950-14959
Design of Nonuniform Static Magnetic Compensation Coils for Magnetic Shielding Room
Near-zero magnetic environment serves as a fundamental research condition for multiple scientific fields. To obtain a large-scale and high-performance near-zero magnetic environment, this paper presents a coil design method based on the boundary element method (BEM) for compensating the non-uniform static magnetic field existing in the magnetic shielding room (MSR). To achieve precise compensation of non-uniform magnetic field, BEM-based image method is introduced to eliminate the deviation by coupling between the magnetic field generated by the coil and the magnetic shielding material, and the gray wolf optimization (GWO) algorithm is employed for the optimal design of coils. The experimental results show that the coils designed by the method of this paper can effectively compensate the non-uniform magnetic field distribution within a 100 mm × 100 mm × 100 mm central area of the MSR. The range of the residual magnetic field has been reduced by 87.8%, thereby establishing an environment below 1 nT in the central area of the MSR. The proposed method will lay the foundation for the research of high-performance non-uniform magnetic compensation coils within the MSR.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14950-14959
Design of Nonuniform Static Magnetic Compensation Coils for Magnetic Shielding Room
Near-zero magnetic environment serves as a fundamental research condition for multiple scientific fields. To obtain a large-scale and high-performance near-zero magnetic environment, this paper presents a coil design method based on the boundary element method (BEM) for compensating the non-uniform static magnetic field existing in the magnetic shielding room (MSR). To achieve precise compensation of non-uniform magnetic field, BEM-based image method is introduced to eliminate the deviation by coupling between the magnetic field generated by the coil and the magnetic shielding material, and the gray wolf optimization (GWO) algorithm is employed for the optimal design of coils. The experimental results show that the coils designed by the method of this paper can effectively compensate the non-uniform magnetic field distribution within a 100 mm × 100 mm × 100 mm central area of the MSR. The range of the residual magnetic field has been reduced by 87.8%, thereby establishing an environment below 1 nT in the central area of the MSR. The proposed method will lay the foundation for the research of high-performance non-uniform magnetic compensation coils within the MSR.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Design Method of Cylindrical Self-Shielding Coils in Spindle-Shaped Magnetic Shielding Cylinders Eliminating Ferromagnetic Boundary Coupling
The uniformity of the coils is often compromised by the coupling between ferromagnetic materials and coils. The spindle-shaped magnetic shielding cylinder (sMSC) has additional benefits over the magnetic shielding cylinder (MSC). A single-layer cylindrical self-shielding coil designed by the improved target field method (TFM) that is available inside sMSC is proposed. The method dynamically regulates the internal uniformity and external self-shielding performance by assigning different weights to the internal and external field points. To reduce the dependence of the traditional TFM design on relevant factors, the hunter-prey optimization (HPO) is applied to optimize it. The modelling and experimental findings reveal that the maximum homogeneity deviations of the self-shielding coil are 0.24% and 0.28%, respectively. The self-shielded coil takes up less space in comparison to the normal non-moment Helmholtz coils. This method ensures the uniform performance of the internal magnetic field (MF) while rapidly attenuating the external MF.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Design Method of Cylindrical Self-Shielding Coils in Spindle-Shaped Magnetic Shielding Cylinders Eliminating Ferromagnetic Boundary Coupling
The uniformity of the coils is often compromised by the coupling between ferromagnetic materials and coils. The spindle-shaped magnetic shielding cylinder (sMSC) has additional benefits over the magnetic shielding cylinder (MSC). A single-layer cylindrical self-shielding coil designed by the improved target field method (TFM) that is available inside sMSC is proposed. The method dynamically regulates the internal uniformity and external self-shielding performance by assigning different weights to the internal and external field points. To reduce the dependence of the traditional TFM design on relevant factors, the hunter-prey optimization (HPO) is applied to optimize it. The modelling and experimental findings reveal that the maximum homogeneity deviations of the self-shielding coil are 0.24% and 0.28%, respectively. The self-shielded coil takes up less space in comparison to the normal non-moment Helmholtz coils. This method ensures the uniform performance of the internal magnetic field (MF) while rapidly attenuating the external MF.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Design of Cylindrical Coils Within Spindle-Shaped Magnetic Shielding Cylinders Using Conformal Mapping
The coupling effect between the active magnetic compensation coil and the ferromagnetic material in the spindle-shaped magnetic shielding cylinder (sMSC) normally leads to distortion of the target magnetic field. The existing methods for designing coils within ferromagnetic boundaries are mainly for regular magnetic shielding cylinder (MSC) and cubic magnetic shielding room (MSR); there is currently no analytical method available for designing coils within ferromagnetic boundaries for sMSC. In this article, a new method based on conformal mapping and target field method (CM-TFM) for designing high uniformity cylindrical coils within a closed sMSC is introduced. It addresses the issue of degradation in magnetic field uniformity due to the coupling of the axial uniform field coil with the magnetic shielding ferromagnetic material inside the sMSC. The simulations indicate that the maximum magnetic field deviation in the target area is reduced from 4.04% to 1.38% in the CM-TFM compared to the coil designed using the conventional target field method (TFM) without considering the coupling effect of the magnetically shielded ferromagnetic material and the coil. The overall percentage of the target area with the magnetic field deviation less than 1% is 92.59% in CM-TFM coils, compared to only 40.74% in TFM coils. The experimental results confirm the effectiveness and practicality of this design method in compensating for the residual magnetic field of sMSC. The proposed approach is essential for the implementation of near-zero magnetic field environments.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Design of Cylindrical Coils Within Spindle-Shaped Magnetic Shielding Cylinders Using Conformal Mapping
The coupling effect between the active magnetic compensation coil and the ferromagnetic material in the spindle-shaped magnetic shielding cylinder (sMSC) normally leads to distortion of the target magnetic field. The existing methods for designing coils within ferromagnetic boundaries are mainly for regular magnetic shielding cylinder (MSC) and cubic magnetic shielding room (MSR); there is currently no analytical method available for designing coils within ferromagnetic boundaries for sMSC. In this article, a new method based on conformal mapping and target field method (CM-TFM) for designing high uniformity cylindrical coils within a closed sMSC is introduced. It addresses the issue of degradation in magnetic field uniformity due to the coupling of the axial uniform field coil with the magnetic shielding ferromagnetic material inside the sMSC. The simulations indicate that the maximum magnetic field deviation in the target area is reduced from 4.04% to 1.38% in the CM-TFM compared to the coil designed using the conventional target field method (TFM) without considering the coupling effect of the magnetically shielded ferromagnetic material and the coil. The overall percentage of the target area with the magnetic field deviation less than 1% is 92.59% in CM-TFM coils, compared to only 40.74% in TFM coils. The experimental results confirm the effectiveness and practicality of this design method in compensating for the residual magnetic field of sMSC. The proposed approach is essential for the implementation of near-zero magnetic field environments.