Jędrzej Kociński
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jędrzej Kociński has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Anna Pastusiak
Department of Acoustics, Faculty of Physics and Astronomy, Adam Mickiewicz University
3 shared publications - Łukasz Błasiński
Department of Acoustics, Faculty of Physics and Astronomy, Adam Mickiewicz UniversityPoznań, Poland
3 shared publications - Dawid Niemiec
Promity Sp. Z o.o., Ul. Wiejska 14/25, 00-490 Warszawa, Poland
2 shared publications Edward Ozimek
Institute of Acoustics Faculty of Physics Adam Mickiewicz University Umultowska 85 61-614 Poznań Poland
2 shared publications- Adam Biniakowski
StethoMe Sp. z o.o., Poznań, Poland
1 shared publication Adam Maciaszek
Department of Acoustics, Faculty of Physics, Adam Mickiewicz University in Poznań, Poznań, Poland
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by EDP Sciences in Acta Acustica
- Vol. 10, 76
Speech intelligibility in halls with Reverberation Enhancement Systems
Speech intelligibility is one of the most important aspects of room acoustics and is commonly evaluated in relation to objective parameters such as Reverberation Time (RT), Early Decay Time (EDT), and Clarity for speech (C50). As Reverberation Enhancement Systems (RES) become more popular, the aim of this research is to investigate objective and subjective speech perception in rooms equipped with such a system. Objective parameters of room acoustics: RT, EDT, C50 and STI (Speech Transmission Index) were measured in four RES-equipped rooms. Additionally, a listening test involving 240 subjects with normal hearing was performed to assess the subjective intelligibility with the Logatome Intelligibility (LI) index. Speech stimuli convolved with a room impulse response were presented to listeners. Comparing objective (STI) and subjective (LI) intelligibility results with objective parameters of room acoustics revealed some differences compared to rooms without RES. Intelligibility in RES-equipped interiors exhibited a smaller decrease in LI with increasing RT, which might be caused by nonlinear decrement of reverberation. These findings suggest the possibility of designing spaces with extended RTs without sacrificing speech clarity and, consequently, intelligibility. The results contribute to the ongoing discourse on the relationship between objective metrics and subjective evaluations of room acoustics for speech intelligibility.
- 28 August 2026
- Published by EDP Sciences in Acta Acustica
- Vol. 10, 76
Open AccessSpeech intelligibility in halls with Reverberation Enhancement Systems
Speech intelligibility is one of the most important aspects of room acoustics and is commonly evaluated in relation to objective parameters such as Reverberation Time (RT), Early Decay Time (EDT), and Clarity for speech (C50). As Reverberation Enhancement Systems (RES) become more popular, the aim of this research is to investigate objective and subjective speech perception in rooms equipped with such a system. Objective parameters of room acoustics: RT, EDT, C50 and STI (Speech Transmission Index) were measured in four RES-equipped rooms. Additionally, a listening test involving 240 subjects with normal hearing was performed to assess the subjective intelligibility with the Logatome Intelligibility (LI) index. Speech stimuli convolved with a room impulse response were presented to listeners. Comparing objective (STI) and subjective (LI) intelligibility results with objective parameters of room acoustics revealed some differences compared to rooms without RES. Intelligibility in RES-equipped interiors exhibited a smaller decrease in LI with increasing RT, which might be caused by nonlinear decrement of reverberation. These findings suggest the possibility of designing spaces with extended RTs without sacrificing speech clarity and, consequently, intelligibility. The results contribute to the ongoing discourse on the relationship between objective metrics and subjective evaluations of room acoustics for speech intelligibility.
- 11 September 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- p. 321-329
Listening Effort in Reverberant Rooms: A Comparative Study of Subjective Perception and Objective Acoustic Metrics
Modern room acoustics employs a variety of objective measures to characterize the acoustical properties of interiors. Despite these advancements, the relationship between these parameters and subjective assessments of room acoustics remains unclear. Subjective perception, particularly listening effort (LE), plays a critical role in how individuals experience acoustic environments, even when speech intelligibility (SI) is high. This study aims to bridge the gap between objective acoustic measures and subjective listening experiences. We conducted experiments in three rooms equipped with reverberation enhancement systems, resulting in nine different acoustic settings. Objective parameters, including reverberation time (RT), early decay time (EDT), clarity (C50), and the speech transmission index (STI), were measured. Additionally, subjective SI was assessed, and LE was rated on a 7-step Likert scale by 180 volunteers with normal hearing. The analysis revealed a nonlinear relationship between LE and both RT20 and EDT (R2 = 0.6), with an even weaker correlation for LE vs. C50 (R2 = 0.46). The Pearson correlation coefficient for STI was 0.74, compared to 0.55 for SI. These findings indicate that the relationship between LE and objective parameters, as well as SI, is complex and not straightforward. Our results suggest the importance of incorporating LE into room acoustic design and evaluation. The disparity between objective measures and subjective experiences suggests that LE may be a crucial factor in accurately assessing acoustic environments. This approach sheds the light on a more holistic understanding of acoustic quality that prioritizes human perception.
- 11 September 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- p. 321-329
Listening Effort in Reverberant Rooms: A Comparative Study of Subjective Perception and Objective Acoustic Metrics
Modern room acoustics employs a variety of objective measures to characterize the acoustical properties of interiors. Despite these advancements, the relationship between these parameters and subjective assessments of room acoustics remains unclear. Subjective perception, particularly listening effort (LE), plays a critical role in how individuals experience acoustic environments, even when speech intelligibility (SI) is high. This study aims to bridge the gap between objective acoustic measures and subjective listening experiences. We conducted experiments in three rooms equipped with reverberation enhancement systems, resulting in nine different acoustic settings. Objective parameters, including reverberation time (RT), early decay time (EDT), clarity (C50), and the speech transmission index (STI), were measured. Additionally, subjective SI was assessed, and LE was rated on a 7-step Likert scale by 180 volunteers with normal hearing. The analysis revealed a nonlinear relationship between LE and both RT20 and EDT (R2 = 0.6), with an even weaker correlation for LE vs. C50 (R2 = 0.46). The Pearson correlation coefficient for STI was 0.74, compared to 0.55 for SI. These findings indicate that the relationship between LE and objective parameters, as well as SI, is complex and not straightforward. Our results suggest the importance of incorporating LE into room acoustic design and evaluation. The disparity between objective measures and subjective experiences suggests that LE may be a crucial factor in accurately assessing acoustic environments. This approach sheds the light on a more holistic understanding of acoustic quality that prioritizes human perception.
- Open Access
- 21 February 2025
- Published by Emerald Publishing in Central European Management Journal
- Vol. ahead-of-p (ahead-of-p)
Integration of knowledge and technology in the co-production of AI-based solutions for the healthcare sector
Purpose: This article aims to explain how organizations create and integrate medical knowledge to develop AI-based medical solutions. The study resulted from a discussion on value co-production with digital technologies and the capabilities needed for it.Design/methodology/approach: The study explores the case of value co-production with the digitalization of traditional medical stethoscopes. It considers integrated resources to create AI-based medical solutions, actors engaged in co-production and activities related mainly to knowledge embodiment.Findings: This article presents operand and operant resources integration when AI is implemented in innovative medical solutions. Furthermore, it shows which activities are undertaken for value co-production and what roles actors from various fields play in resource integration.Originality/value: Our article discusses the integration of knowledge and the role of knowledge embodiment among resource integration in value co-production when working on AI.
- 21 February 2025
- Published by Emerald Publishing in Central European Management Journal
- Vol. ahead-of-p (ahead-of-p)
Open AccessIntegration of knowledge and technology in the co-production of AI-based solutions for the healthcare sector
Purpose: This article aims to explain how organizations create and integrate medical knowledge to develop AI-based medical solutions. The study resulted from a discussion on value co-production with digital technologies and the capabilities needed for it.Design/methodology/approach: The study explores the case of value co-production with the digitalization of traditional medical stethoscopes. It considers integrated resources to create AI-based medical solutions, actors engaged in co-production and activities related mainly to knowledge embodiment.Findings: This article presents operand and operant resources integration when AI is implemented in innovative medical solutions. Furthermore, it shows which activities are undertaken for value co-production and what roles actors from various fields play in resource integration.Originality/value: Our article discusses the integration of knowledge and the role of knowledge embodiment among resource integration in value co-production when working on AI.
- 18 February 2025
- Published by Elsevier in Journal of Cystic Fibrosis
- Vol. 24 (2) , 390-397
AI-facilitated home monitoring for cystic fibrosis exacerbations across pediatric and adult populations
- 18 February 2025
- Published by Elsevier in Journal of Cystic Fibrosis
- Vol. 24 (2) , 390-397
AI-facilitated home monitoring for cystic fibrosis exacerbations across pediatric and adult populations
- 1 July 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (1) , 450-462
Perception of reverberation length in rooms with reverberation enhancement systems
This study examined the perception of reverberation length in rooms equipped with a reverberation enhancement system (RES). In the past, many acousticians have studied the correlation between subjective reverberation ratings and objective criteria in concert halls; the effect of RES on these ratings has not been thoroughly investigated. The decay of acoustic energy in rooms with RES has double-slope characteristics, which is different from most impulse responses recorded in rooms without such a system. The study showed a difference in the evaluation of perceived stop-chord and running reverberation length. The results also suggest that not only the initial part, but also the latter part of the impulse response should be considered when evaluating the perception of reverberation length. These findings contribute to a better understanding of the relationship between subjective perception and objective measures of reverberation length and provide insight into the perceptual evaluation of acoustic environments.
- 1 July 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (1) , 450-462
Perception of reverberation length in rooms with reverberation enhancement systems
This study examined the perception of reverberation length in rooms equipped with a reverberation enhancement system (RES). In the past, many acousticians have studied the correlation between subjective reverberation ratings and objective criteria in concert halls; the effect of RES on these ratings has not been thoroughly investigated. The decay of acoustic energy in rooms with RES has double-slope characteristics, which is different from most impulse responses recorded in rooms without such a system. The study showed a difference in the evaluation of perceived stop-chord and running reverberation length. The results also suggest that not only the initial part, but also the latter part of the impulse response should be considered when evaluating the perception of reverberation length. These findings contribute to a better understanding of the relationship between subjective perception and objective measures of reverberation length and provide insight into the perceptual evaluation of acoustic environments.
- Open Access
- 11 November 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Artificial Intelligence Approach to the Monitoring of Respiratory Sounds in Asthmatic Patients
Background: Effective and reliable monitoring of asthma at home is a relevant factor that may reduce the need to consult a doctor in person.Aim: We analyzed the possibility to determine intensities of pathological breath phenomena based on artificial intelligence (AI) analysis of sounds recorded during standard stethoscope auscultation.Methods: The evaluation set comprising 1,043 auscultation examinations (9,319 recordings) was collected from 899 patients. Examinations were assigned to one of four groups: asthma with and without abnormal sounds (AA and AN, respectively), no-asthma with and without abnormal sounds (NA and NN, respectively). Presence of abnormal sounds was evaluated by a panel of 3 physicians that were blinded to the AI predictions. AI was trained on an independent set of 9,847 recordings to determine intensity scores (indexes) of wheezes, rhonchi, fine and coarse crackles and their combinations: continuous phenomena (wheezes + rhonchi) and all phenomena. The pair-comparison of groups of examinations based on Area Under ROC-Curve (AUC) was used to evaluate the performance of each index in discrimination between groups.Results: Best performance in separation between AA and AN was observed with Continuous Phenomena Index (AUC 0.94) while for NN and NA. All Phenomena Index (AUC 0.91) showed the best performance. AA showed slightly higher prevalence of wheezes compared to NA.Conclusions: The results showed a high efficiency of the AI to discriminate between the asthma patients with normal and abnormal sounds, thus this approach has a great potential and can be used to monitor asthma symptoms at home.
- 11 November 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Open AccessArtificial Intelligence Approach to the Monitoring of Respiratory Sounds in Asthmatic Patients
Background: Effective and reliable monitoring of asthma at home is a relevant factor that may reduce the need to consult a doctor in person.Aim: We analyzed the possibility to determine intensities of pathological breath phenomena based on artificial intelligence (AI) analysis of sounds recorded during standard stethoscope auscultation.Methods: The evaluation set comprising 1,043 auscultation examinations (9,319 recordings) was collected from 899 patients. Examinations were assigned to one of four groups: asthma with and without abnormal sounds (AA and AN, respectively), no-asthma with and without abnormal sounds (NA and NN, respectively). Presence of abnormal sounds was evaluated by a panel of 3 physicians that were blinded to the AI predictions. AI was trained on an independent set of 9,847 recordings to determine intensity scores (indexes) of wheezes, rhonchi, fine and coarse crackles and their combinations: continuous phenomena (wheezes + rhonchi) and all phenomena. The pair-comparison of groups of examinations based on Area Under ROC-Curve (AUC) was used to evaluate the performance of each index in discrimination between groups.Results: Best performance in separation between AA and AN was observed with Continuous Phenomena Index (AUC 0.94) while for NN and NA. All Phenomena Index (AUC 0.91) showed the best performance. AA showed slightly higher prevalence of wheezes compared to NA.Conclusions: The results showed a high efficiency of the AI to discriminate between the asthma patients with normal and abnormal sounds, thus this approach has a great potential and can be used to monitor asthma symptoms at home.
- Open Access
- 31 December 2019
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- Vol. 44 (4) , 709-717
The Benefit of Binaural Hearing Among Listeners with Sensorineural Hearing Loss
The performance of binaural processing may be disturbed in the presence of hearing loss, especially of sensorineural type. To assess the impact of hearing loss on speech perception in noise regarding binaural processing, series of speech recognition measurements in controlled laboratory conditions were carried out. The spatial conditions were simulated using dummy head recordings played back on headphones. The Intelligibility Level Difference (ILD) was determined by measuring the change in the speech reception thresholds (SRT) between two configurations of a masking signal source (N) and a speech source (S), namely the S0N90 condition (where numbers stand for angles in horizontal plane) and the co-located condition (S0N0). To disentangle the head shadow effect (better ear effect) from binaural processing in the brain, the difference between binaural and monaural S0N90 condition (so-called Binaural Intelligibility Level Difference, BILD) value was calculated. Measurements were performed with a control group of normal-hearing listeners and a group of sensorineural hearing-impaired subjects. In all conditions performance of the hearing-impaired listeners was significantly lower than normal-hearing ones, resulting in higher SRT values (3 dB difference in the S0N0 configuration, 7.6 dB in S0N90 and 5 dB in monaural S0N90). The SRT improvement due to the spatial separation of target and masking signal (ILD) was also higher in the control group (8.1 dB) than in hearing-impaired listeners (3.5 dB). Moreover, a significant deterioration of the binaural processing described by BILD was found in people with sensorineural deficits. This parameter for normal-hearing listeners reached a value of 3 to 6 dB (4.6 dB on average) and decreased more than two times in the hearing-impaired group to 1.9 dB on average (with a deviation of 1.4 dB). These findings could not be explained by individual average hearing threshold (standard in audiological diagnostics) only. The outcomes indicate that there is a contribution of suprathershold deficits and it may be useful to consider binaural SRT measurements in noise in addition to the pure tone audiometry resulting in better diagnostics and hearing aid fitting.
- 31 December 2019
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- Vol. 44 (4) , 709-717
Open AccessThe Benefit of Binaural Hearing Among Listeners with Sensorineural Hearing Loss
The performance of binaural processing may be disturbed in the presence of hearing loss, especially of sensorineural type. To assess the impact of hearing loss on speech perception in noise regarding binaural processing, series of speech recognition measurements in controlled laboratory conditions were carried out. The spatial conditions were simulated using dummy head recordings played back on headphones. The Intelligibility Level Difference (ILD) was determined by measuring the change in the speech reception thresholds (SRT) between two configurations of a masking signal source (N) and a speech source (S), namely the S0N90 condition (where numbers stand for angles in horizontal plane) and the co-located condition (S0N0). To disentangle the head shadow effect (better ear effect) from binaural processing in the brain, the difference between binaural and monaural S0N90 condition (so-called Binaural Intelligibility Level Difference, BILD) value was calculated. Measurements were performed with a control group of normal-hearing listeners and a group of sensorineural hearing-impaired subjects. In all conditions performance of the hearing-impaired listeners was significantly lower than normal-hearing ones, resulting in higher SRT values (3 dB difference in the S0N0 configuration, 7.6 dB in S0N90 and 5 dB in monaural S0N90). The SRT improvement due to the spatial separation of target and masking signal (ILD) was also higher in the control group (8.1 dB) than in hearing-impaired listeners (3.5 dB). Moreover, a significant deterioration of the binaural processing described by BILD was found in people with sensorineural deficits. This parameter for normal-hearing listeners reached a value of 3 to 6 dB (4.6 dB on average) and decreased more than two times in the hearing-impaired group to 1.9 dB on average (with a deviation of 1.4 dB). These findings could not be explained by individual average hearing threshold (standard in audiological diagnostics) only. The outcomes indicate that there is a contribution of suprathershold deficits and it may be useful to consider binaural SRT measurements in noise in addition to the pure tone audiometry resulting in better diagnostics and hearing aid fitting.
- Open Access
- 26 September 2017
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 42 (3) , 385-394
Logatome and Sentence Recognition Related to Acoustic Parameters of Enclosures
The paper deals with relationship between speech recognition and objective parameters of enclosures. Six enclosures were chosen: a church, an assembly hall of a music school, two courtrooms of different volumes, a typical auditorium and a university concert hall. Dirac 4.1 software was used to record impulse responses (IRs) in the chosen measurement points of each enclosure. On this base, the following objective parameters of the enclosure were determined: Reverberation Time (RT), Early Decay Time (EDT), Weighted Clarity (C50) and Speech Transmission Index (STI). A convolution of the IRs with logatome tests and the Polish Sentence Test (PST) was made. Logatome recognition and speech reception threshold (SRT - i.e., SNR yielding 50% speech recognition) were evaluated and their dependence on the objective parameters were determined. Generally a linear relationship between logatome or SRT and RT or EDT was found. However, speech recognition was nonlinearly related (according to psychometric function) to STI values. The most sensitive range of the logatome and sentence recognition relative to STI changes corresponded to the middle range of STI values. Below and above this range, logatome and sentence recognition were much less dependent of STI changes.
- 26 September 2017
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 42 (3) , 385-394
Open AccessLogatome and Sentence Recognition Related to Acoustic Parameters of Enclosures
The paper deals with relationship between speech recognition and objective parameters of enclosures. Six enclosures were chosen: a church, an assembly hall of a music school, two courtrooms of different volumes, a typical auditorium and a university concert hall. Dirac 4.1 software was used to record impulse responses (IRs) in the chosen measurement points of each enclosure. On this base, the following objective parameters of the enclosure were determined: Reverberation Time (RT), Early Decay Time (EDT), Weighted Clarity (C50) and Speech Transmission Index (STI). A convolution of the IRs with logatome tests and the Polish Sentence Test (PST) was made. Logatome recognition and speech reception threshold (SRT - i.e., SNR yielding 50% speech recognition) were evaluated and their dependence on the objective parameters were determined. Generally a linear relationship between logatome or SRT and RT or EDT was found. However, speech recognition was nonlinearly related (according to psychometric function) to STI values. The most sensitive range of the logatome and sentence recognition relative to STI changes corresponded to the middle range of STI values. Below and above this range, logatome and sentence recognition were much less dependent of STI changes.
- 1 December 2016
- Published by Elsevier in Applied Acoustics
- Vol. 113, 58-63
Time-compressed speech intelligibility in different reverberant conditions
- 1 December 2016
- Published by Elsevier in Applied Acoustics
- Vol. 113, 58-63
Time-compressed speech intelligibility in different reverberant conditions
- Open Access
- 1 June 2016
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 41 (2) , 255-264
Speech Recognition in an Enclosure with a Long Reverberation Time
The aim of this work was to measure subjective speech intelligibility in an enclosure with a long reverberation time and comparison of these results with objective parameters. Impulse Responses (IRs) were first determined with a dummy head in different measurement points of the enclosure. The following objective parameters were calculated with Dirac 4.1 software: Reverberation Time (RT), Early Decay Time (EDT), weighted Clarity (C50) and Speech Transmission Index (STI). For the chosen measurement points, a convolution of the IRs with the Polish Sentence Test (PST) and logatome tests was made. PST was presented at a background of a babble noise and speech reception threshold - SRT (i.e. SNR yielding 50% speech intelligibility) for those points were evaluated. A relationship of the sentence and logatome recognition vs. STI was determined. It was found that the final SRT data are well correlated with speech transmission index (STI), and can be expressed by a psychometric function. The difference between SRT determined in condition without reverberation and in reverberation conditions appeared to be a good measure of the effect of reverberation on speech intelligibility in a room. In addition, speech intelligibility, with and without use of the sound amplification system installed in the enclosure, was compared.
- 1 June 2016
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 41 (2) , 255-264
Open AccessSpeech Recognition in an Enclosure with a Long Reverberation Time
The aim of this work was to measure subjective speech intelligibility in an enclosure with a long reverberation time and comparison of these results with objective parameters. Impulse Responses (IRs) were first determined with a dummy head in different measurement points of the enclosure. The following objective parameters were calculated with Dirac 4.1 software: Reverberation Time (RT), Early Decay Time (EDT), weighted Clarity (C50) and Speech Transmission Index (STI). For the chosen measurement points, a convolution of the IRs with the Polish Sentence Test (PST) and logatome tests was made. PST was presented at a background of a babble noise and speech reception threshold - SRT (i.e. SNR yielding 50% speech intelligibility) for those points were evaluated. A relationship of the sentence and logatome recognition vs. STI was determined. It was found that the final SRT data are well correlated with speech transmission index (STI), and can be expressed by a psychometric function. The difference between SRT determined in condition without reverberation and in reverberation conditions appeared to be a good measure of the effect of reverberation on speech intelligibility in a room. In addition, speech intelligibility, with and without use of the sound amplification system installed in the enclosure, was compared.