Anna Pastusiak
Research Subjects
Anna Pastusiak has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jędrzej Kociński
Department of Acoustics, Faculty of Physics and Astronomy, Adam Mickiewicz UniversityPoznań, Poland
3 shared publications - Łukasz Błasiński
Department of Acoustics, Faculty of Physics and Astronomy, Adam Mickiewicz UniversityPoznań, Poland
2 shared publications Anna Bręborowicz
Department of Pediatric Pneumonology, Allergology and Clinical Immunology, K. Jonscher Clinical Hospital, Poznań University of Medical Sciences, Szpitalna 27/33, 60-572, Poznań, Poland
1 shared publication- Anna Warzybok
Medizinische Physik, Carl von Ossietzky Universität Oldenburg
1 shared publication - Dawid Niemiec
Promity Sp. Z o.o., Ul. Wiejska 14/25, 00-490 Warszawa, Poland
1 shared publication - Honorata Hafke-Dys
Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego, Poland
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by EDP Sciences in Acta Acustica
- Vol. 10, 76
Speech intelligibility in halls with Reverberation Enhancement Systems
Speech intelligibility is one of the most important aspects of room acoustics and is commonly evaluated in relation to objective parameters such as Reverberation Time (RT), Early Decay Time (EDT), and Clarity for speech (C50). As Reverberation Enhancement Systems (RES) become more popular, the aim of this research is to investigate objective and subjective speech perception in rooms equipped with such a system. Objective parameters of room acoustics: RT, EDT, C50 and STI (Speech Transmission Index) were measured in four RES-equipped rooms. Additionally, a listening test involving 240 subjects with normal hearing was performed to assess the subjective intelligibility with the Logatome Intelligibility (LI) index. Speech stimuli convolved with a room impulse response were presented to listeners. Comparing objective (STI) and subjective (LI) intelligibility results with objective parameters of room acoustics revealed some differences compared to rooms without RES. Intelligibility in RES-equipped interiors exhibited a smaller decrease in LI with increasing RT, which might be caused by nonlinear decrement of reverberation. These findings suggest the possibility of designing spaces with extended RTs without sacrificing speech clarity and, consequently, intelligibility. The results contribute to the ongoing discourse on the relationship between objective metrics and subjective evaluations of room acoustics for speech intelligibility.
- 28 August 2026
- Published by EDP Sciences in Acta Acustica
- Vol. 10, 76
Open AccessSpeech intelligibility in halls with Reverberation Enhancement Systems
Speech intelligibility is one of the most important aspects of room acoustics and is commonly evaluated in relation to objective parameters such as Reverberation Time (RT), Early Decay Time (EDT), and Clarity for speech (C50). As Reverberation Enhancement Systems (RES) become more popular, the aim of this research is to investigate objective and subjective speech perception in rooms equipped with such a system. Objective parameters of room acoustics: RT, EDT, C50 and STI (Speech Transmission Index) were measured in four RES-equipped rooms. Additionally, a listening test involving 240 subjects with normal hearing was performed to assess the subjective intelligibility with the Logatome Intelligibility (LI) index. Speech stimuli convolved with a room impulse response were presented to listeners. Comparing objective (STI) and subjective (LI) intelligibility results with objective parameters of room acoustics revealed some differences compared to rooms without RES. Intelligibility in RES-equipped interiors exhibited a smaller decrease in LI with increasing RT, which might be caused by nonlinear decrement of reverberation. These findings suggest the possibility of designing spaces with extended RTs without sacrificing speech clarity and, consequently, intelligibility. The results contribute to the ongoing discourse on the relationship between objective metrics and subjective evaluations of room acoustics for speech intelligibility.
- 11 September 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- p. 321-329
Listening Effort in Reverberant Rooms: A Comparative Study of Subjective Perception and Objective Acoustic Metrics
Modern room acoustics employs a variety of objective measures to characterize the acoustical properties of interiors. Despite these advancements, the relationship between these parameters and subjective assessments of room acoustics remains unclear. Subjective perception, particularly listening effort (LE), plays a critical role in how individuals experience acoustic environments, even when speech intelligibility (SI) is high. This study aims to bridge the gap between objective acoustic measures and subjective listening experiences. We conducted experiments in three rooms equipped with reverberation enhancement systems, resulting in nine different acoustic settings. Objective parameters, including reverberation time (RT), early decay time (EDT), clarity (C50), and the speech transmission index (STI), were measured. Additionally, subjective SI was assessed, and LE was rated on a 7-step Likert scale by 180 volunteers with normal hearing. The analysis revealed a nonlinear relationship between LE and both RT20 and EDT (R2 = 0.6), with an even weaker correlation for LE vs. C50 (R2 = 0.46). The Pearson correlation coefficient for STI was 0.74, compared to 0.55 for SI. These findings indicate that the relationship between LE and objective parameters, as well as SI, is complex and not straightforward. Our results suggest the importance of incorporating LE into room acoustic design and evaluation. The disparity between objective measures and subjective experiences suggests that LE may be a crucial factor in accurately assessing acoustic environments. This approach sheds the light on a more holistic understanding of acoustic quality that prioritizes human perception.
- 11 September 2025
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- p. 321-329
Listening Effort in Reverberant Rooms: A Comparative Study of Subjective Perception and Objective Acoustic Metrics
Modern room acoustics employs a variety of objective measures to characterize the acoustical properties of interiors. Despite these advancements, the relationship between these parameters and subjective assessments of room acoustics remains unclear. Subjective perception, particularly listening effort (LE), plays a critical role in how individuals experience acoustic environments, even when speech intelligibility (SI) is high. This study aims to bridge the gap between objective acoustic measures and subjective listening experiences. We conducted experiments in three rooms equipped with reverberation enhancement systems, resulting in nine different acoustic settings. Objective parameters, including reverberation time (RT), early decay time (EDT), clarity (C50), and the speech transmission index (STI), were measured. Additionally, subjective SI was assessed, and LE was rated on a 7-step Likert scale by 180 volunteers with normal hearing. The analysis revealed a nonlinear relationship between LE and both RT20 and EDT (R2 = 0.6), with an even weaker correlation for LE vs. C50 (R2 = 0.46). The Pearson correlation coefficient for STI was 0.74, compared to 0.55 for SI. These findings indicate that the relationship between LE and objective parameters, as well as SI, is complex and not straightforward. Our results suggest the importance of incorporating LE into room acoustic design and evaluation. The disparity between objective measures and subjective experiences suggests that LE may be a crucial factor in accurately assessing acoustic environments. This approach sheds the light on a more holistic understanding of acoustic quality that prioritizes human perception.
- Open Access
- 31 December 2019
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- Vol. 44 (4) , 709-717
The Benefit of Binaural Hearing Among Listeners with Sensorineural Hearing Loss
The performance of binaural processing may be disturbed in the presence of hearing loss, especially of sensorineural type. To assess the impact of hearing loss on speech perception in noise regarding binaural processing, series of speech recognition measurements in controlled laboratory conditions were carried out. The spatial conditions were simulated using dummy head recordings played back on headphones. The Intelligibility Level Difference (ILD) was determined by measuring the change in the speech reception thresholds (SRT) between two configurations of a masking signal source (N) and a speech source (S), namely the S0N90 condition (where numbers stand for angles in horizontal plane) and the co-located condition (S0N0). To disentangle the head shadow effect (better ear effect) from binaural processing in the brain, the difference between binaural and monaural S0N90 condition (so-called Binaural Intelligibility Level Difference, BILD) value was calculated. Measurements were performed with a control group of normal-hearing listeners and a group of sensorineural hearing-impaired subjects. In all conditions performance of the hearing-impaired listeners was significantly lower than normal-hearing ones, resulting in higher SRT values (3 dB difference in the S0N0 configuration, 7.6 dB in S0N90 and 5 dB in monaural S0N90). The SRT improvement due to the spatial separation of target and masking signal (ILD) was also higher in the control group (8.1 dB) than in hearing-impaired listeners (3.5 dB). Moreover, a significant deterioration of the binaural processing described by BILD was found in people with sensorineural deficits. This parameter for normal-hearing listeners reached a value of 3 to 6 dB (4.6 dB on average) and decreased more than two times in the hearing-impaired group to 1.9 dB on average (with a deviation of 1.4 dB). These findings could not be explained by individual average hearing threshold (standard in audiological diagnostics) only. The outcomes indicate that there is a contribution of suprathershold deficits and it may be useful to consider binaural SRT measurements in noise in addition to the pure tone audiometry resulting in better diagnostics and hearing aid fitting.
- 31 December 2019
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- Vol. 44 (4) , 709-717
Open AccessThe Benefit of Binaural Hearing Among Listeners with Sensorineural Hearing Loss
The performance of binaural processing may be disturbed in the presence of hearing loss, especially of sensorineural type. To assess the impact of hearing loss on speech perception in noise regarding binaural processing, series of speech recognition measurements in controlled laboratory conditions were carried out. The spatial conditions were simulated using dummy head recordings played back on headphones. The Intelligibility Level Difference (ILD) was determined by measuring the change in the speech reception thresholds (SRT) between two configurations of a masking signal source (N) and a speech source (S), namely the S0N90 condition (where numbers stand for angles in horizontal plane) and the co-located condition (S0N0). To disentangle the head shadow effect (better ear effect) from binaural processing in the brain, the difference between binaural and monaural S0N90 condition (so-called Binaural Intelligibility Level Difference, BILD) value was calculated. Measurements were performed with a control group of normal-hearing listeners and a group of sensorineural hearing-impaired subjects. In all conditions performance of the hearing-impaired listeners was significantly lower than normal-hearing ones, resulting in higher SRT values (3 dB difference in the S0N0 configuration, 7.6 dB in S0N90 and 5 dB in monaural S0N90). The SRT improvement due to the spatial separation of target and masking signal (ILD) was also higher in the control group (8.1 dB) than in hearing-impaired listeners (3.5 dB). Moreover, a significant deterioration of the binaural processing described by BILD was found in people with sensorineural deficits. This parameter for normal-hearing listeners reached a value of 3 to 6 dB (4.6 dB on average) and decreased more than two times in the hearing-impaired group to 1.9 dB on average (with a deviation of 1.4 dB). These findings could not be explained by individual average hearing threshold (standard in audiological diagnostics) only. The outcomes indicate that there is a contribution of suprathershold deficits and it may be useful to consider binaural SRT measurements in noise in addition to the pure tone audiometry resulting in better diagnostics and hearing aid fitting.
- Open Access
- 29 March 2019
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 178 (6) , 883-890
Practical implementation of artificial intelligence algorithms in pulmonary auscultation examination
Lung auscultation is an important part of a physical examination. However, its biggest drawback is its subjectivity. The results depend on the experience and ability of the doctor to perceive and distinguish pathologies in sounds heard via a stethoscope. This paper investigates a new method of automatic sound analysis based on neural networks (NNs), which has been implemented in a system that uses an electronic stethoscope for capturing respiratory sounds. It allows the detection of auscultatory sounds in four classes: wheezes, rhonchi, and fine and coarse crackles. In the blind test, a group of 522 auscultatory sounds from 50 pediatric patients were presented, and the results provided by a group of doctors and an artificial intelligence (AI) algorithm developed by the authors were compared. The gathered data show that machine learning (ML)–based analysis is more efficient in detecting all four types of phenomena, which is reflected in high values of recall (also called as sensitivity) and F1-score.
- 29 March 2019
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 178 (6) , 883-890
Open AccessPractical implementation of artificial intelligence algorithms in pulmonary auscultation examination
Lung auscultation is an important part of a physical examination. However, its biggest drawback is its subjectivity. The results depend on the experience and ability of the doctor to perceive and distinguish pathologies in sounds heard via a stethoscope. This paper investigates a new method of automatic sound analysis based on neural networks (NNs), which has been implemented in a system that uses an electronic stethoscope for capturing respiratory sounds. It allows the detection of auscultatory sounds in four classes: wheezes, rhonchi, and fine and coarse crackles. In the blind test, a group of 522 auscultatory sounds from 50 pediatric patients were presented, and the results provided by a group of doctors and an artificial intelligence (AI) algorithm developed by the authors were compared. The gathered data show that machine learning (ML)–based analysis is more efficient in detecting all four types of phenomena, which is reflected in high values of recall (also called as sensitivity) and F1-score.