Jiachen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiachen Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Feihu Zheng
Tongji University
5 shared publications - Xingzhe Zhao
Tongji University
2 shared publications Changbing Wu
Tongji University
1 shared publication- Gilbert Teyssedre
LAPLACE, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
1 shared publication Pengyue Wang
Department of Electrical Engineering, Tongji University, Shanghai, China
1 shared publication- Shijie Chen
Department of Electrical Engineering, Tongji University, Shanghai, China
1 shared publication
Latest Publications
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3761-3763
Thermal Pulse Method for Space Charge Measurement in Micrometer-Thin Polyimide Films Under Ultrahigh Temperature
Thermal Pulse Method (TPM) technique, which can reach the spatial resolution of sub-micron level, exhibits significant advantages in elevated temperature for space charge measurement in micrometer-thin polymer films. With enhancements to the heating and measurement setup, the TPM—which inherently operates without the need for sensing elements—enables accurate determination of space charge and internal electric fields in 8 μm-thick polyimide (PI) films across a wide temperature range from 25 °C to 250 °C. The experimental results indicate that elevated temperatures can significantly influence charge accumulation and evolution in polyimide (PI). While charge injection is nearly symmetric between positive and negative carriers at room temperature, a dominant accumulation of negative charges is observed above 100 °C. This tendency intensifies with temperature, and at 250 °C, the resulting electric field distortion approaches 30%.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3761-3763
Thermal Pulse Method for Space Charge Measurement in Micrometer-Thin Polyimide Films Under Ultrahigh Temperature
Thermal Pulse Method (TPM) technique, which can reach the spatial resolution of sub-micron level, exhibits significant advantages in elevated temperature for space charge measurement in micrometer-thin polymer films. With enhancements to the heating and measurement setup, the TPM—which inherently operates without the need for sensing elements—enables accurate determination of space charge and internal electric fields in 8 μm-thick polyimide (PI) films across a wide temperature range from 25 °C to 250 °C. The experimental results indicate that elevated temperatures can significantly influence charge accumulation and evolution in polyimide (PI). While charge injection is nearly symmetric between positive and negative carriers at room temperature, a dominant accumulation of negative charges is observed above 100 °C. This tendency intensifies with temperature, and at 250 °C, the resulting electric field distortion approaches 30%.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2389-2397
Relationship Between Prestress Breakdown and Space Charge in Micrometer-Thin Metalized Polymer Films
Micron-thin polymer films often endure harsh operating environments such as high electric fields and high temperatures, when utilized as insulating or capacitive media. These conditions may cause significant space charge accumulation, potentially leading to premature breakdown of the film. However, due to the limitations in space charge measurement techniques, there are few reports on the relationship between space charge accumulation and prestress breakdown in micron thin films. In this work, the relationship between the space charge and prestress failure in double-sided metallized biaxially-oriented polypropylene (BOPP) film with a thickness of 3.8 μm is investigated. Both DC prestress treatment and breakdown testing of the thin films are conducted using a ball plate electrode. The Weibull breakdown distribution illustrates the impact of prestress voltage and duration on the breakdown strength of the thin films. The residual electric field of the films, induced by space charge accumulation during prestress treatment, is measured using the thermal pulse method (TPM). The data indicates that the breakdown strength of the samples subjected to prestress treatment decreases, with the degree of decrease in breakdown strength is basically consistent with the highest residual electric field of prestress treatment in numerical values. This experimentally demonstrates that the accumulation of space charges is the direct cause of the decrease in breakdown field strength in micron thin films.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2389-2397
Relationship Between Prestress Breakdown and Space Charge in Micrometer-Thin Metalized Polymer Films
Micron-thin polymer films often endure harsh operating environments such as high electric fields and high temperatures, when utilized as insulating or capacitive media. These conditions may cause significant space charge accumulation, potentially leading to premature breakdown of the film. However, due to the limitations in space charge measurement techniques, there are few reports on the relationship between space charge accumulation and prestress breakdown in micron thin films. In this work, the relationship between the space charge and prestress failure in double-sided metallized biaxially-oriented polypropylene (BOPP) film with a thickness of 3.8 μm is investigated. Both DC prestress treatment and breakdown testing of the thin films are conducted using a ball plate electrode. The Weibull breakdown distribution illustrates the impact of prestress voltage and duration on the breakdown strength of the thin films. The residual electric field of the films, induced by space charge accumulation during prestress treatment, is measured using the thermal pulse method (TPM). The data indicates that the breakdown strength of the samples subjected to prestress treatment decreases, with the degree of decrease in breakdown strength is basically consistent with the highest residual electric field of prestress treatment in numerical values. This experimentally demonstrates that the accumulation of space charges is the direct cause of the decrease in breakdown field strength in micron thin films.