Xingzhe Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingzhe Zhao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Feihu Zheng
Tongji University
3 shared publications - Jiachen Li
Tongji University
2 shared publications Changbing Wu
Tongji University
1 shared publication- Gilbert Teyssedre
LAPLACE, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
1 shared publication - Haotian He
Department of Electrical Engineering, Tongji University, Shanghai, China
1 shared publication
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Research on Defect Localization of Power Cables Using Compressed Sensing-Based FDR Method
Frequency Domain Reflectometry (FDR) is widely used for detecting and locating local defects in power cables. However, noise, multiple reflections, and spectral leakage can generate spurious peaks and sidelobes in the FDR spectrum, which may mislead defect localization. Moreover, FDR testing requires the collection of a large volume of data, placing high demands on on-site storage and real-time processing. This study proposes a compressed sensing (CS)-based method for defect localization in power cables. The method first preprocesses the raw signal using Variational Mode Decomposition (VMD) and windowing and performs compressed sampling with a sparse random measurement matrix, after which the signal is reconstructed and preliminarily denoised under the Discrete Fourier Transform (DFT) basis, followed by sparse reconstruction under the Chirp Z-Transform (CZT) basis to obtain a sparse representation. Simulations and field tests verify that the proposed method maintains high localization accuracy even under high compression ratios, while effectively suppressing spurious peaks and sidelobe interference.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Research on Defect Localization of Power Cables Using Compressed Sensing-Based FDR Method
Frequency Domain Reflectometry (FDR) is widely used for detecting and locating local defects in power cables. However, noise, multiple reflections, and spectral leakage can generate spurious peaks and sidelobes in the FDR spectrum, which may mislead defect localization. Moreover, FDR testing requires the collection of a large volume of data, placing high demands on on-site storage and real-time processing. This study proposes a compressed sensing (CS)-based method for defect localization in power cables. The method first preprocesses the raw signal using Variational Mode Decomposition (VMD) and windowing and performs compressed sampling with a sparse random measurement matrix, after which the signal is reconstructed and preliminarily denoised under the Discrete Fourier Transform (DFT) basis, followed by sparse reconstruction under the Chirp Z-Transform (CZT) basis to obtain a sparse representation. Simulations and field tests verify that the proposed method maintains high localization accuracy even under high compression ratios, while effectively suppressing spurious peaks and sidelobe interference.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3761-3763
Thermal Pulse Method for Space Charge Measurement in Micrometer-Thin Polyimide Films Under Ultrahigh Temperature
Thermal Pulse Method (TPM) technique, which can reach the spatial resolution of sub-micron level, exhibits significant advantages in elevated temperature for space charge measurement in micrometer-thin polymer films. With enhancements to the heating and measurement setup, the TPM—which inherently operates without the need for sensing elements—enables accurate determination of space charge and internal electric fields in 8 μm-thick polyimide (PI) films across a wide temperature range from 25 °C to 250 °C. The experimental results indicate that elevated temperatures can significantly influence charge accumulation and evolution in polyimide (PI). While charge injection is nearly symmetric between positive and negative carriers at room temperature, a dominant accumulation of negative charges is observed above 100 °C. This tendency intensifies with temperature, and at 250 °C, the resulting electric field distortion approaches 30%.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3761-3763
Thermal Pulse Method for Space Charge Measurement in Micrometer-Thin Polyimide Films Under Ultrahigh Temperature
Thermal Pulse Method (TPM) technique, which can reach the spatial resolution of sub-micron level, exhibits significant advantages in elevated temperature for space charge measurement in micrometer-thin polymer films. With enhancements to the heating and measurement setup, the TPM—which inherently operates without the need for sensing elements—enables accurate determination of space charge and internal electric fields in 8 μm-thick polyimide (PI) films across a wide temperature range from 25 °C to 250 °C. The experimental results indicate that elevated temperatures can significantly influence charge accumulation and evolution in polyimide (PI). While charge injection is nearly symmetric between positive and negative carriers at room temperature, a dominant accumulation of negative charges is observed above 100 °C. This tendency intensifies with temperature, and at 250 °C, the resulting electric field distortion approaches 30%.