Asif Raza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Asif Raza has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Tariq Yasin
Department of Chemistry Pakistan Institute of Engineering and Applied Sciences (PIEAS) Islamabad Pakistan
5 shared publications - Amara Nasir
Department of Physics The University of Lahore Lahore Pakistan
2 shared publications Hafiz Zain Ul Aabidin
Department of Chemical Engineering, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, Pakistan
2 shared publications- Mehwish Tahir
Department of Chemistry, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
2 shared publications Muhammad Inam Ul Hassan
Department of Chemical Engineering, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, Pakistan
2 shared publicationsMuhammad Zubair Rahim
Department of Chemical Engineering, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, Pakistan
2 shared publications
Latest Publications
- Open Access
- 20 October 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (5) , 647-662
K-carrageenan fabricated γ-irradiated graphene oxide hydrogel: A versatile anticancer nanodrug carrier system
In this study, gamma-irradiated graphene oxide was incorporated into novel pH-responsive hydrogels. The biopolymer kappa carrageenan was blended with polyvinyl alcohol in a silane crosslinked biopolymer, and the effect of gamma irradiation dosage was studied. Nonhazardous tetraethoxysilane (TEOS) was used as a crosslinker. The hydrogels were characterized with chemical and thermal analysis, scanning electron microscopy, and structural analysis using a variety of analytical tools. The swelling behavior of fabricated hydrogels was assessed in various solution media. As the pH of the media increased, the swelling ratio of hydrogels decreased. All fabricated hydrogels had a high swelling ratio at acidic and neutral pH levels, with a decrease in swelling observed at basic pH. The pH-sensitive response at pH 7 make these hydrogels of potential use for controlled injectable-based drug delivery. Hydrogels with the highest swelling percentage were successfully loaded with letrozole (LTZ) to investigate the release mechanism. The drug release test was conducted in PBS and it showed that hydrogel released the LTZ in a regulated manner up to 99% in 4 h. These findings suggest that the hydrogels could serve as intelligent, responsive materials for controlled drug delivery and other biomedical applications at physiological pH.
- 20 October 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (5) , 647-662
Open AccessK-carrageenan fabricated γ-irradiated graphene oxide hydrogel: A versatile anticancer nanodrug carrier system
In this study, gamma-irradiated graphene oxide was incorporated into novel pH-responsive hydrogels. The biopolymer kappa carrageenan was blended with polyvinyl alcohol in a silane crosslinked biopolymer, and the effect of gamma irradiation dosage was studied. Nonhazardous tetraethoxysilane (TEOS) was used as a crosslinker. The hydrogels were characterized with chemical and thermal analysis, scanning electron microscopy, and structural analysis using a variety of analytical tools. The swelling behavior of fabricated hydrogels was assessed in various solution media. As the pH of the media increased, the swelling ratio of hydrogels decreased. All fabricated hydrogels had a high swelling ratio at acidic and neutral pH levels, with a decrease in swelling observed at basic pH. The pH-sensitive response at pH 7 make these hydrogels of potential use for controlled injectable-based drug delivery. Hydrogels with the highest swelling percentage were successfully loaded with letrozole (LTZ) to investigate the release mechanism. The drug release test was conducted in PBS and it showed that hydrogel released the LTZ in a regulated manner up to 99% in 4 h. These findings suggest that the hydrogels could serve as intelligent, responsive materials for controlled drug delivery and other biomedical applications at physiological pH.
- Open Access
- 18 August 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (4) , 460-469
Dielectric and mechanical properties of polyaniline-grafted sepiolite loaded PVC nanocomposites
Conducting polymers exhibit interesting dielectric properties due to their unique conjugated π-electron backbone. The objective of this study was to examine the dielectric properties of nanocomposites containing a conducting nanohybrid (NH) as a filler. Polyaniline was grafted onto sepiolite by in situ emulsion graft polymerization to synthesize a conducting NH. This NH was blended with poly(vinyl chloride) (PVC) using a melt blending technique. Nanocomposites with variable amounts of nanofiller were prepared and characterized. Fourier-transform infrared (FT-IR) spectra of the NH composites show strong interactions between their individual components. The addition of the nanofiller into PVC increased its thermomechanical properties. Dielectric loss factor and permittivity increased with nanofiller content and decreased frequency, exhibiting strong interfacial polarization in the low frequency range. Incorporation of the nanofiller into the PVC matrix increased conductivity up to 7.9 × 10−7 S/cm and substantially decreased impedance. The results demonstrate the potential of the nanocomposite for electromagnetic interference shielding, biomedical applications, biosensing, and environmental sensing.
- 18 August 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (4) , 460-469
Open AccessDielectric and mechanical properties of polyaniline-grafted sepiolite loaded PVC nanocomposites
Conducting polymers exhibit interesting dielectric properties due to their unique conjugated π-electron backbone. The objective of this study was to examine the dielectric properties of nanocomposites containing a conducting nanohybrid (NH) as a filler. Polyaniline was grafted onto sepiolite by in situ emulsion graft polymerization to synthesize a conducting NH. This NH was blended with poly(vinyl chloride) (PVC) using a melt blending technique. Nanocomposites with variable amounts of nanofiller were prepared and characterized. Fourier-transform infrared (FT-IR) spectra of the NH composites show strong interactions between their individual components. The addition of the nanofiller into PVC increased its thermomechanical properties. Dielectric loss factor and permittivity increased with nanofiller content and decreased frequency, exhibiting strong interfacial polarization in the low frequency range. Incorporation of the nanofiller into the PVC matrix increased conductivity up to 7.9 × 10−7 S/cm and substantially decreased impedance. The results demonstrate the potential of the nanocomposite for electromagnetic interference shielding, biomedical applications, biosensing, and environmental sensing.
- Open Access
- 17 February 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (1) , 89-102
Masking of iron and other interferences during the spectrophotometric analysis of aluminum from soil samples using Alizarin Red S
In whole-rock geochemical analysis, the quantification of aluminum in geological samples is performed using differentanalytical techniques including UV-Vis spectrophotometry. During the spectrophotometric analysis of aluminum utilizing AlizarinRed S, iron causes significant interference, leading to inaccurate measurements of the amount of aluminum in the sample. In caseswhere leached or processed samples contain titanium, interference is also observed. However, appropriate masking agents can removethese interferences. In this study, various masking agents including Tiron, oxalic acid, ascorbic acid, and thioglycolic acid were utilizedfor the masking of iron. Among these masking agents, ascorbic acid proved to be the best candidate for masking iron. A simple andefficient method was then developed for the masking of iron with the optimization of parameters including concentration of ascorbicacid and reaction time. With this technique, 2 mL of ascorbic acid (10%) can mask iron at up to 3000 ppm in aliquots. Moreover,titanium interference is not observed with this method when the titanium concentration in the aliquot is below 100 ppm. This methodwas subsequently applied to geological samples and the results were compared to those of atomic absorption spectroscopy. Most samplescan easily be analyzed for aluminum by utilizing this masking technique and circumventing interference problems.
- 17 February 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (1) , 89-102
Open AccessMasking of iron and other interferences during the spectrophotometric analysis of aluminum from soil samples using Alizarin Red S
In whole-rock geochemical analysis, the quantification of aluminum in geological samples is performed using differentanalytical techniques including UV-Vis spectrophotometry. During the spectrophotometric analysis of aluminum utilizing AlizarinRed S, iron causes significant interference, leading to inaccurate measurements of the amount of aluminum in the sample. In caseswhere leached or processed samples contain titanium, interference is also observed. However, appropriate masking agents can removethese interferences. In this study, various masking agents including Tiron, oxalic acid, ascorbic acid, and thioglycolic acid were utilizedfor the masking of iron. Among these masking agents, ascorbic acid proved to be the best candidate for masking iron. A simple andefficient method was then developed for the masking of iron with the optimization of parameters including concentration of ascorbicacid and reaction time. With this technique, 2 mL of ascorbic acid (10%) can mask iron at up to 3000 ppm in aliquots. Moreover,titanium interference is not observed with this method when the titanium concentration in the aliquot is below 100 ppm. This methodwas subsequently applied to geological samples and the results were compared to those of atomic absorption spectroscopy. Most samplescan easily be analyzed for aluminum by utilizing this masking technique and circumventing interference problems.
- 1 January 2025
- Published by Tech Science Press in Journal of Polymer Materials
- Vol. 42 (1) , 141-150
Removal of Iron from Leached Geological Samples Using Polypropylene Waste Amidoxime-Based Radiation Grafted Adsorbent
Geological samples often contain significant amounts of iron, which, although not typically the target element, can substantially interfere with the analysis of other elements of interest. To mitigate these interferences, amidoxime-based radiation grafted adsorbents have been identified as effective for iron removal. In this study, an amidoxime-functionalized, radiation-grafted adsorbent synthesized from polypropylene waste (PPw-g-AO-10) was employed to remove iron from leached geological samples. The adsorption process was systematically optimized by investigating the effects of pH, contact time, adsorbent dosage, and initial ferric ion concentration. Under optimal conditions—pH 1.4, a contact time of 90 min, and an initial ferric ion concentration of 4500 mg/L—the adsorbent exhibited a maximum iron adsorption capacity of 269.02 mg/g. After optimizing the critical adsorption parameters, the adsorbent was applied to the leached geological samples, achieving a 91% removal of the iron content. The adsorbent was regenerated through two consecutive cycles using 0.2 N HNO3, achieving a regeneration efficiency of 65%. These findings confirm the efficacy of the synthesized PPw-g-AO-10 as a cost-effective and eco-friendly adsorbent for successfully removing iron from leached geological matrices while maintaining a reasonable degree of reusability.
- 1 January 2025
- Published by Tech Science Press in Journal of Polymer Materials
- Vol. 42 (1) , 141-150
Removal of Iron from Leached Geological Samples Using Polypropylene Waste Amidoxime-Based Radiation Grafted Adsorbent
Geological samples often contain significant amounts of iron, which, although not typically the target element, can substantially interfere with the analysis of other elements of interest. To mitigate these interferences, amidoxime-based radiation grafted adsorbents have been identified as effective for iron removal. In this study, an amidoxime-functionalized, radiation-grafted adsorbent synthesized from polypropylene waste (PPw-g-AO-10) was employed to remove iron from leached geological samples. The adsorption process was systematically optimized by investigating the effects of pH, contact time, adsorbent dosage, and initial ferric ion concentration. Under optimal conditions—pH 1.4, a contact time of 90 min, and an initial ferric ion concentration of 4500 mg/L—the adsorbent exhibited a maximum iron adsorption capacity of 269.02 mg/g. After optimizing the critical adsorption parameters, the adsorbent was applied to the leached geological samples, achieving a 91% removal of the iron content. The adsorbent was regenerated through two consecutive cycles using 0.2 N HNO3, achieving a regeneration efficiency of 65%. These findings confirm the efficacy of the synthesized PPw-g-AO-10 as a cost-effective and eco-friendly adsorbent for successfully removing iron from leached geological matrices while maintaining a reasonable degree of reusability.
- Open Access
- 14 June 2024
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 48 (3) , 484-505
Design and characterization of phosphonic acid-functionalized grafted sepiolite nanohybrids and their adsorption studies for removal of copper ions from aqueous solution
In this study, we synthesized novel, economically efficient phosphonic acid-functionalized grafted sepiolite nanohybrids for selective elimination of copper ions from water. These nanohybrids were prepared by graft polymerization of glycidyl methacrylate onto sepiolite. We utilized free radical graft polymerization to graft glycidyl methacrylate (GMA) onto silanized sepiolite. The nanohybrids obtained exhibited a grafting percentage of 479% at 0.3 g of KPS initiator, 15% GMA monomer, and after 4 h of reaction. In pursuit of selectively removing metal ions from water, the nanohybrid with the highest grafting (PGE3) was chemically treated with phosphoric acid to introduce phosphonic acid groups on it. FTIR, XRD, SEM, CHO analysis, BET, and TGA analysis were utilized to characterize the developed nanohybrids. Batch adsorption studies were carried out using AAS process, examining the impact of pH, adsorbent weight, contact time, adsorbate concentration, and temperature on the adsorption process. Due to the selectivity of phosphonic acid groups towards copper ions, phosphonic acid-functionalized grafted sepiolite nanohybrid (PGE3-P) was used for copper ions removal from its aqueous solution. The maximum adsorption capacity of PGE3-P adsorbents was 134.5 mg/g for copper ions. The data from kinetic studies suggests that the adsorption process of copper ions followed a pseudosecond-order model. Furthermore, Langmuir isotherm proved to be a more fitting model in equilibrium isothermal investigations.The thermodynamic analysis of the data indicates that the adsorption of copper ions by PGE3-P is an endothermic and spontaneous process. The development of this phosphonic acid-functionalized grafted sepiolite nanohybrid adsorbent is a new contribution into the field of adsorption. The developed material can be utilized as selective adsorbent for elimination of other heavy metals from water.
- 14 June 2024
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 48 (3) , 484-505
Open AccessDesign and characterization of phosphonic acid-functionalized grafted sepiolite nanohybrids and their adsorption studies for removal of copper ions from aqueous solution
In this study, we synthesized novel, economically efficient phosphonic acid-functionalized grafted sepiolite nanohybrids for selective elimination of copper ions from water. These nanohybrids were prepared by graft polymerization of glycidyl methacrylate onto sepiolite. We utilized free radical graft polymerization to graft glycidyl methacrylate (GMA) onto silanized sepiolite. The nanohybrids obtained exhibited a grafting percentage of 479% at 0.3 g of KPS initiator, 15% GMA monomer, and after 4 h of reaction. In pursuit of selectively removing metal ions from water, the nanohybrid with the highest grafting (PGE3) was chemically treated with phosphoric acid to introduce phosphonic acid groups on it. FTIR, XRD, SEM, CHO analysis, BET, and TGA analysis were utilized to characterize the developed nanohybrids. Batch adsorption studies were carried out using AAS process, examining the impact of pH, adsorbent weight, contact time, adsorbate concentration, and temperature on the adsorption process. Due to the selectivity of phosphonic acid groups towards copper ions, phosphonic acid-functionalized grafted sepiolite nanohybrid (PGE3-P) was used for copper ions removal from its aqueous solution. The maximum adsorption capacity of PGE3-P adsorbents was 134.5 mg/g for copper ions. The data from kinetic studies suggests that the adsorption process of copper ions followed a pseudosecond-order model. Furthermore, Langmuir isotherm proved to be a more fitting model in equilibrium isothermal investigations.The thermodynamic analysis of the data indicates that the adsorption of copper ions by PGE3-P is an endothermic and spontaneous process. The development of this phosphonic acid-functionalized grafted sepiolite nanohybrid adsorbent is a new contribution into the field of adsorption. The developed material can be utilized as selective adsorbent for elimination of other heavy metals from water.
- Open Access
- 29 December 2023
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 47 (6) , 1334-1345
Polypyrrole fabricated Laponite RD conductive nanocomposites: influence of grafting efficiency on structural and conductive properties
In the present work novel conductive organic-inorganic nanocomposites were produced by grafting of pyrrole monomer onto silanized Laponite RD utilizing emulsion graft polymerization. Influence of some important factors like concentration of monomer, initiator and surfactant were investigated on grafting efficiency. Grafting of polypyrrole chains onto modified Laponite RD was verified by Fourier transform infrared spectroscopy (FT-IR). Scanning electron microscope (SEM) revealed the spherical particles of nanocomposite with average diameter of 271.5 nm. XRD pattern showed that molecular framework of pure polypyrrole almost remains same in nanocomposite. Surface area and pore volume of Laponite RD, measured by Brunauer-Emmett-Teller (BET) analysis, was also altered indicating effective grafting of polypyrrole chains onto modified substrate. Maximum grafting efficiency (%), determined gravimetrically, was 87.3% at monomer, initiator, and surfactant concentrations of 1.50, 1.00, and 0.50% respectively. Prepared nanocomposites with grafting efficiency of 87.3% have displayed maximum electrical conductivity of 0.23 × 10-2 Scm−1. These nanocomposites can be used for manifold applications like biomedical and energy storage devices.
- 29 December 2023
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 47 (6) , 1334-1345
Open AccessPolypyrrole fabricated Laponite RD conductive nanocomposites: influence of grafting efficiency on structural and conductive properties
In the present work novel conductive organic-inorganic nanocomposites were produced by grafting of pyrrole monomer onto silanized Laponite RD utilizing emulsion graft polymerization. Influence of some important factors like concentration of monomer, initiator and surfactant were investigated on grafting efficiency. Grafting of polypyrrole chains onto modified Laponite RD was verified by Fourier transform infrared spectroscopy (FT-IR). Scanning electron microscope (SEM) revealed the spherical particles of nanocomposite with average diameter of 271.5 nm. XRD pattern showed that molecular framework of pure polypyrrole almost remains same in nanocomposite. Surface area and pore volume of Laponite RD, measured by Brunauer-Emmett-Teller (BET) analysis, was also altered indicating effective grafting of polypyrrole chains onto modified substrate. Maximum grafting efficiency (%), determined gravimetrically, was 87.3% at monomer, initiator, and surfactant concentrations of 1.50, 1.00, and 0.50% respectively. Prepared nanocomposites with grafting efficiency of 87.3% have displayed maximum electrical conductivity of 0.23 × 10-2 Scm−1. These nanocomposites can be used for manifold applications like biomedical and energy storage devices.
- 5 February 2020
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 137 (37)
Sepiolite grafted polypyrrole: Influence of degree of grafting on structural, thermal, and impedance properties of nanohybrid
Conductive pyrrole monomer was grafted on vinyl modified sepiolite by surface initiated emulsion graft polymerization. Effect of process variables such as monomer, initiator, and surfactant on degree of grafting (%) were investigated. Maximum 745% degree of grafting was obtained at optimized grafting conditions. Structural changes in sepiolite by grafting of polypyrrole chains was confirmed by Fourier transform infrared spectroscopy and X‐ray diffraction techniques. Surface morphology of the grafted nanohybrid was investigated by scanning electron microscopy (SEM). Thermal studies were carried out to acquire information concerning thermal stability of the synthesized materials and it was found increasing with the increase in grafting (%) of polypyrrole in sepiolite grafted polypyrrole (MS‐g‐PPy). Complex impedance spectroscopic analysis was carried out to study the effects of grafting of PPy on the ac electrical properties of synthesized nanohybrid composite at ambient temperature in the frequency range of 0.5–107 Hz. The value of electrical conductivity was affected by degree of grafting (%) and maximum value of 0.85 × 10−4 S/cm was achieved. Both dielectric loss factor and permittivity increase with the decrease of frequency exhibiting strong interfacial polarization at low frequency.
- 5 February 2020
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 137 (37)
Sepiolite grafted polypyrrole: Influence of degree of grafting on structural, thermal, and impedance properties of nanohybrid
Conductive pyrrole monomer was grafted on vinyl modified sepiolite by surface initiated emulsion graft polymerization. Effect of process variables such as monomer, initiator, and surfactant on degree of grafting (%) were investigated. Maximum 745% degree of grafting was obtained at optimized grafting conditions. Structural changes in sepiolite by grafting of polypyrrole chains was confirmed by Fourier transform infrared spectroscopy and X‐ray diffraction techniques. Surface morphology of the grafted nanohybrid was investigated by scanning electron microscopy (SEM). Thermal studies were carried out to acquire information concerning thermal stability of the synthesized materials and it was found increasing with the increase in grafting (%) of polypyrrole in sepiolite grafted polypyrrole (MS‐g‐PPy). Complex impedance spectroscopic analysis was carried out to study the effects of grafting of PPy on the ac electrical properties of synthesized nanohybrid composite at ambient temperature in the frequency range of 0.5–107 Hz. The value of electrical conductivity was affected by degree of grafting (%) and maximum value of 0.85 × 10−4 S/cm was achieved. Both dielectric loss factor and permittivity increase with the decrease of frequency exhibiting strong interfacial polarization at low frequency.