James Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
James Yu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Baowei Fei
University of Texas at Dallas, Center for Imaging and Surgical Innovation, Richardson, Texas, United States
2 shared publications Anne M. Dumaine
(1) University Hospitals Clevalnd Medical Center, Cleveland, OH
1 shared publication- Connie Poe-Kochert
Rainbow Babies and Children’s Hospital, University Hospitals Case Medical Center
1 shared publication - George H. Thompson
Professor Emeritus, Orthopaedic Surgery, Case Western Reserve University, Cleveland, OH, USA
1 shared publication - Hasan Mubarak
University of Texas at Dallas, Department of Bioengineering, Richardson, Texas
1 shared publication - Kelden Pruitt
University of Texas at Dallas, Center for Imaging and Surgical Innovation, Richardson, Texas, United States
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (03) , 1-12
High-speed optical tracking and augmented reality platform for image-guided interventions
PurposeDuring interventional procedures, clinicians need to mentally register anatomical information from preoperative cross-sectional images onto the patient’s body to envision the location of subsurface targets and critical structures. This study aims to address this challenge by developing an augmented reality (AR)-based tracking system that can leverage cross-sectional images to provide real-time three-dimensional (3D) visualization of lesion targets and enable precise surgical procedures.ApproachOur AR platform combines a customized high-speed, real-time, optical tracking system, a holographic display device, a computer workstation, and a graphical user interface. The system displays holograms of virtual models of the target organ and surgical tools, as well as the navigation path. To validate our AR platform, we measured target registration errors (TRE) across two different types of interventional procedures using our high-speed optical tracking system. To conduct these experiments, we performed laparoscopic procedures and prostate biopsies on customized phantoms.ResultsThe integrated high-speed tracking and AR platform was applied to laparoscopic and biopsy procedures. The average TRE was 4.17±1.63 mm for laparoscopic procedures and 2.89±0.84 mm for prostate biopsy.ConclusionsAn augmented reality platform with a high-speed precision optical tracking system was developed for interventional procedures. The AR platform has been demonstrated for potential applications in prostate laparoscopic and biopsy procedures and can be expanded to other interventional procedures.
- 1 May 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (03) , 1-12
Open AccessHigh-speed optical tracking and augmented reality platform for image-guided interventions
PurposeDuring interventional procedures, clinicians need to mentally register anatomical information from preoperative cross-sectional images onto the patient’s body to envision the location of subsurface targets and critical structures. This study aims to address this challenge by developing an augmented reality (AR)-based tracking system that can leverage cross-sectional images to provide real-time three-dimensional (3D) visualization of lesion targets and enable precise surgical procedures.ApproachOur AR platform combines a customized high-speed, real-time, optical tracking system, a holographic display device, a computer workstation, and a graphical user interface. The system displays holograms of virtual models of the target organ and surgical tools, as well as the navigation path. To validate our AR platform, we measured target registration errors (TRE) across two different types of interventional procedures using our high-speed optical tracking system. To conduct these experiments, we performed laparoscopic procedures and prostate biopsies on customized phantoms.ResultsThe integrated high-speed tracking and AR platform was applied to laparoscopic and biopsy procedures. The average TRE was 4.17±1.63 mm for laparoscopic procedures and 2.89±0.84 mm for prostate biopsy.ConclusionsAn augmented reality platform with a high-speed precision optical tracking system was developed for interventional procedures. The AR platform has been demonstrated for potential applications in prostate laparoscopic and biopsy procedures and can be expanded to other interventional procedures.
- Open Access
- 24 July 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 093505-16
Detection and margin assessment of thyroid carcinoma with microscopic hyperspectral imaging using transformer networks
Thyroid cancer is one of the fastest-growing types of cancer in the United States with an estimated 43,720 new cases registered in 2023 alone.1 Even though a vast majority (more than 90%) of thyroid nodules are benign, some patients would develop malignant tumors that can migrate to other organs.2 The most common types of thyroid cancer originate from follicular epithelial cells. This includes papillary thyroid cancer (80% to 85% of cases3), follicular thyroid cancer, and anaplastic thyroid cancer.2 Medullary thyroid cancer, which accounts for only 1% to 2% of all thyroid cancer cases, originates from the parafollicular C cells.2 Thyroid lobectomy is a common treatment option if immediate risk is detected. During surgery, a pathologist determines the border between benign and cancerous tissue on a frozen section and helps identify the positive margin under a microscope. If cancer remains present at the edge of the tissue, the margin is labeled as positive, suggesting that the tumor was not entirely resected. The acceptable margin for thyroid carcinoma ranges from 5 to 20 mm.4 However, the thyroid region is vital for the quality of life; thus, it is also important to preserve as many non-tumor cells as possible. A balance is needed between a good negative margin and a good living outcome, and correct determination of the margin helps.
- 24 July 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 093505-16
Open AccessDetection and margin assessment of thyroid carcinoma with microscopic hyperspectral imaging using transformer networks
Thyroid cancer is one of the fastest-growing types of cancer in the United States with an estimated 43,720 new cases registered in 2023 alone.1 Even though a vast majority (more than 90%) of thyroid nodules are benign, some patients would develop malignant tumors that can migrate to other organs.2 The most common types of thyroid cancer originate from follicular epithelial cells. This includes papillary thyroid cancer (80% to 85% of cases3), follicular thyroid cancer, and anaplastic thyroid cancer.2 Medullary thyroid cancer, which accounts for only 1% to 2% of all thyroid cancer cases, originates from the parafollicular C cells.2 Thyroid lobectomy is a common treatment option if immediate risk is detected. During surgery, a pathologist determines the border between benign and cancerous tissue on a frozen section and helps identify the positive margin under a microscope. If cancer remains present at the edge of the tissue, the margin is labeled as positive, suggesting that the tumor was not entirely resected. The acceptable margin for thyroid carcinoma ranges from 5 to 20 mm.4 However, the thyroid region is vital for the quality of life; thus, it is also important to preserve as many non-tumor cells as possible. A balance is needed between a good negative margin and a good living outcome, and correct determination of the margin helps.
- 24 February 2021
- Published by American Academy of Pediatrics (AAP)
- Vol. 147 (3 MeetingA) , 792-793
Long Term Outcomes Following Surgical Site Infections in Early Onset Scoliosis Patients: A 15-year Retrospective Review
- 24 February 2021
- Published by American Academy of Pediatrics (AAP)
- Vol. 147 (3 MeetingA) , 792-793
Long Term Outcomes Following Surgical Site Infections in Early Onset Scoliosis Patients: A 15-year Retrospective Review
- 1 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1930529X,p. 1-6
High Level Abstraction Modeling for Network Configuration Validation
This paper presents our design and implementation of a Configuration Validation System (ConfVS) which uses a high-level language to help system operators verify network configurations based on formal requirements. In contrast to many existing solutions, ConfVS uses a comprehensive model to formalize the network specification and utilizes the NETCONF protocol to collect configuration data from network devices. In addition, ConfVS uses binary decision diagrams to model the behavior of network devices and provides a prototype to query the device configuration. Requirements and specifications are written in the Erlang language, a general-purpose concurrent programming language. To validate ConfVS, we present a case study to show the features and the expressiveness of ConfVS by performing different types of reasoning with network requirements.
- 1 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1930529X,p. 1-6
High Level Abstraction Modeling for Network Configuration Validation
This paper presents our design and implementation of a Configuration Validation System (ConfVS) which uses a high-level language to help system operators verify network configurations based on formal requirements. In contrast to many existing solutions, ConfVS uses a comprehensive model to formalize the network specification and utilizes the NETCONF protocol to collect configuration data from network devices. In addition, ConfVS uses binary decision diagrams to model the behavior of network devices and provides a prototype to query the device configuration. Requirements and specifications are written in the Erlang language, a general-purpose concurrent programming language. To validate ConfVS, we present a case study to show the features and the expressiveness of ConfVS by performing different types of reasoning with network requirements.