KPKelden Pruitt

Kelden Pruitt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kelden Pruitt has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-speed optical tracking and augmented reality platform for image-guided interventions

    by Nati Nawawithan, James Yu, Kelden Pruitt, Baowei Fei

    PurposeDuring interventional procedures, clinicians need to mentally register anatomical information from preoperative cross-sectional images onto the patient’s body to envision the location of subsurface targets and critical structures. This study aims to address this challenge by developing an augmented reality (AR)-based tracking system that can leverage cross-sectional images to provide real-time three-dimensional (3D) visualization of lesion targets and enable precise surgical procedures.ApproachOur AR platform combines a customized high-speed, real-time, optical tracking system, a holographic display device, a computer workstation, and a graphical user interface. The system displays holograms of virtual models of the target organ and surgical tools, as well as the navigation path. To validate our AR platform, we measured target registration errors (TRE) across two different types of interventional procedures using our high-speed optical tracking system. To conduct these experiments, we performed laparoscopic procedures and prostate biopsies on customized phantoms.ResultsThe integrated high-speed tracking and AR platform was applied to laparoscopic and biopsy procedures. The average TRE was 4.17±1.63 mm for laparoscopic procedures and 2.89±0.84 mm for prostate biopsy.ConclusionsAn augmented reality platform with a high-speed precision optical tracking system was developed for interventional procedures. The AR platform has been demonstrated for potential applications in prostate laparoscopic and biopsy procedures and can be expanded to other interventional procedures.

  • Open Access

    Development and validation of a high-resolution hyperspectral imaging system for the retina

    by Minh H. Tran, Kelden Pruitt, Michelle Bryarly, Isioma Emordi, Arrsh Ali, Ling Ma, Baowei Fei

    SignificanceEarly detection of Alzheimer’s diseases, diabetic retinopathy, or macular degeneration with advanced retinal imaging technologies can help improve patient care and treatment outcome.AimWe aim to create a high-resolution hyperspectral imaging (HSI) system for the retina. Retinal vessel diameter and oxygenation rate will be extracted simultaneously from HSI data.ApproachOur hyperspectral retinal imaging system consists of a snapshot hyperspectral camera, a high-resolution RGB camera, a beamsplitter, and an imaging endoscope. Multiple pansharpening algorithms, including deep learning methods, were developed to generate high-resolution hyperspectral images that were further used for the measurement of vessel size and oxygenation rate in mice.ResultsThe hyperspectral retinal imaging system was tested for its spatial resolution and spectral fidelity in retina phantoms. In vivo imaging experiments were performed in mice. The deep learning-based pansharpening algorithm achieved a root mean square error (RMSE) of 2.15±0.64, a correlation coefficient (CC) of 0.96±0.05, a spectral angle score of 0.06±0.03 radians, and an error relative global dimensionless synthesis (ERGAS) score of 2.37±1.71. Oxygen saturation (sO2) and lumen diameters of blood vessels were measured in the retina. The average lumen diameter of the venules was 45.7±13.6 μm, whereas the average lumen diameter of the arterioles was 31.5±8.7 μm. The average arteriole sO2 was 98%, whereas the average venule sO2 was 58%.ConclusionsA high-resolution hyperspectral imaging system was developed and validated for retina imaging and measurement of blood vessels and oxygen saturation.


  • Open Access

    Design and validation of a high-speed hyperspectral laparoscopic imaging system

    by Kelden Pruitt, Ling Ma, Armand Rathgeb, Jeffrey C. Gahan, Brett A. Johnson, Douglas W. Strand, Baowei Fei

    Laparoscopic and robotic surgery has been increasing in prevalence across all surgical specialties for decades, in fields that include urology,1 neurology,2 and gynecology.3 This has resulted in shorter hospital stays, decreased intraoperative blood loss, and decreased infection rates in patients.4,5 As minimally invasive surgery (MIS) and techniques have evolved and improved, surgical robotics and novel imaging systems have further advanced the field and enhanced surgeon capabilities in various procedures. This includes the development of fluorescence imaging (FI) systems,6 3D stereoscopic visualization technology,7 and narrow-band imaging (NBI) tools,8 all of which have been incorporated into MIS imaging systems with the hope of reducing adverse outcomes such as anastomotic leakage occurrence rates,9 iatrogenic injuries,10 and positive tumor margins.11 As these technologies have been shown to improve surgical outcomes, they have seen increased translation in modern, clinical systems. As such, we will briefly cover each in more depth.