DCDavide Raimondi Cominesi

Davide Raimondi Cominesi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Davide Raimondi Cominesi has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Baydur Ratio Correction on the Reliability of Esophageal Pressure Measurement

    by Andrea Restivo, Michele Delle Vergini, Genevieve McCormack, Timothy G. Gaulton, Glasiele Alcala, Davide Raimondi Cominesi, Elisa Mereto, Sarah E. Gerard, Rehab Khalid, Rajiv Gupta, et al.

    Tidal changes in esophageal pressure (ΔPes) are used as a surrogate for pleural pressure changes (ΔPpl) to assess chest wall mechanics. The Baydur ratio evaluates pressure transmission and guides catheter positioning. The effects of correcting ΔPes using the Baydur ratio on the accuracy of ΔPpl estimation and its dependence on ventilation mode, spontaneous inspiratory effort, and body position, remain unclear. In ten pigs, ΔPpl was measured using intrapleural balloon catheters, while Pes was recorded at three esophageal locations in supine and prone positions. Animals underwent controlled and assisted ventilation. Baydur ratios were derived during assisted ventilation and from external chest compressions during controlled ventilation. ΔPes before and after correction was compared with ΔPpl using mixed-effects models and Bland–Altman analysis. Additionally, we quantified the proportion of values with (ΔPes−ΔPpl) ≤ 1 cmH₂O. During assisted ventilation, ΔPes showed good agreement with posterior ΔPpl. Baydur correction improved scaling and association (slope 0.76 vs 0.50; r 0.81 vs 0.79, p<0.01) and increased values within ±1 cmH₂O from 29% to 45% when the Baydur ratio fell outside the accepted range. During controlled ventilation, ΔPes showed weaker association and wider limits of agreement, without improvement after correction. Similar patterns were observed in prone position. ΔPes more accurately reflected posterior ΔPpl during assisted ventilation. Baydur correction improves scaling and association, particularly when the Baydur ratio falls outside the accepted range, but does not improve and may worsen agreement during controlled ventilation.

  • Open Access

    Effect of varying driving pressure and respiratory rate on ventilator‐induced lung injury in healthy and injured lungs: An experimental animal study

    by Davide Raimondi Cominesi, Vanessa Zambelli, Emma J. Murphy, Roberta Garberi, Aurora Magliocca, Roberto Fumagalli, Giacomo Bellani, Giuseppe Foti, Maurizio Cereda, John G. Laffey, et al.

    Ventilator‐induced lung injury (VILI) is a major complication of mechanical ventilation. A combined index of driving pressure (DP) and respiratory rate (RR), expressed as 4DP+RR, has been proposed to predict VILI risk. We investigated whether different combinations of DP and RR, whilst keeping 4DP+RR constant, result in different degrees of VILI in healthy (Series 1) and hydrochloric acid‐injured rat lungs (Series 2). Rats were ventilated for 4 h (Series 1) or 2 h (Series 2) using five combinations of DP and RR, targeting a constant 4DP+RR equal to 140. We assessed gas exchange, partitioned respiratory mechanics, lung micro‐computed tomography (microCT), bronchoalveolar lavage (BAL) and alveolar tissue histology. In Series 1, the highest DP with the lowest RR, led to impaired gas exchange, compliance reduction and increased inflammation, with evidence of a threshold effect in clinical parameters and a progressive increase in histological damage. In Series 2, the lung damage progressed linearly with increasing DP and decreasing RR. Despite a constant 4DP+RR, mechanical power (MP) paradoxically decreased as DP increased. In Series 1, inflammation occurred before detectable tissue damage. A threshold effect in clinical markers (oxygenation, compliance and microCT) alongside progressively increasing histological injury suggests that early lung injury may follow a two‐phase progression. In Series 2, VILI progressed linearly with increasing DP and decreasing RR despite a constant 4DP+RR load. These findings support a complex interplay between DP, RR and the spatial distribution of energy dissipation as key determinants of VILI. image Key points: Ventilator‐induced lung injury (VILI) is a major complication of mechanical ventilation; the index combining driving pressure (DP) and respiratory rate (RR) ‐ 4DP+RR ‐ has been proposed to estimate the risk of VILI. Different combinations of DP and RR, while keeping 4DP+RR constant, may exert distinct effects on lung injury. We show that higher DP with lower RR exacerbates lung injury, despite a fixed 4DP+RR, and pre‐injured lungs exhibit heightened vulnerability as compared to healthy lungs. Transpulmonary DP correlates strongly with structural injury as assessed by lung micro‐Computed Tomography and histology, whereas mechanical power shows an unexpected inverse trend as DP increases and RR decreases. These findings demonstrate that a fixed 4DP+RR does not ensure lung protection and highlight DPRR interactions and spatial energy dissipation as key determinants of VILI progression.


  • Prone-position decreases airway closure in a patient with ARDS undergoing venovenous extracorporeal membrane oxygenation

    by Marco Giani, Andrea Restivo, Davide Raimondi Cominesi, Rosa Fracchia, Matteo Pozzi, Lorenzo Del Sorbo, Giuseppe Foti, Laurent Brochard, Emanuele Rezoagli

    Purpose Airway closure is a interruption of communication between larger and smaller airways. The presence of airway closure during mechanical ventilation may lead to the overestimation of driving pressure (DP), introducing errors in the assessment of respiratory mechanics and in positive end-expiratory pressure (PEEP) setting on the ventilator. Patients with severe acute respiratory distress syndrome (ARDS) may exhibit the airway closure phenomenon, which can be easily diagnosed with a low-flow inflation. Prone positioning is a therapeutic manoeuver proven to reduce mortality in ARDS patients, and has been widely implemented also in patients requiring veno-venous extracorporeal membrane oxygenation (V-V ECMO). To date, the impact of prone positioning on changes in airway closure has not been described. Methods We present an image analysis of the pressure waveform during volume-controlled ventilation and low-flow inflations before and after prone positioning in an ARDS patient on VV ECMO. Results A high airway opening pressure level (23 cmH2O) was detected in the supine position during tidal ventilation. Airway closure was confirmed by using a low-flow inflation. Prone positioning significantly attenuated airway closure, with the airway opening pressure decreasing to 13 cmH2O. After re-supination, airway closure was lower as compared with supine position at baseline (17 cmH2O). Conclusion Prone positioning reduced airway closure in an ARDS patient on VV ECMO support.


  • Multiple organ failure induced by septic shock in an unusual case of massive necrotizing fasciitis of the trunk

    by Davide Raimondi Cominesi, Aurora Magliocca, Emanuele Rezoagli, Giovanni Vitale, Stefano Olmi, Matteo Giacomini

    Article: Multiple organ failure induced by septic shock in an unusual case of massive necrotizing fasciitis of the trunk - Chirurgia 2023 August;36(4):224-7 - Minerva Medica - Journals